5-8
CAUTIONS
1. DISCONNECT THE POWER SUPPLY CORD FROM THE OUTLET WHENEVER REMOVING THE
OUTER CASE FROM THE UNIT. PROCEED WITH THE TEST ONLY AFTER DISCHARGING THE HIGH
VOLTAGE CAPACITOR AND REMOVING THE WIRE LEADS FROM THE PRIMARY WINDING OF THE
HIGH VOLTAGE TRANSFORMER. (SEE PAGE 2-1)
2. ALL OPERATIONAL CHECKS WITH MICROWAVE ENERGY MUST BE DONE WITH A LOAD (1 LITER
OF WATER IN CONTAINER) IN THE OVEN.
COMPONENTS
TEST PROCEDURE
RESULTS
HIGH VOLTAGE
TRANSFORMER
(Wire leads removed)
MAGNETRON
(Wire leads removed)
1. Measure the resistance.
(Ohm-meter scale: Rx1 and Rx100)
• Primary winding
• Secondary winding
• Filament winding
2. Measure the resistance.
(Ohm-meter scale: Rx1000)
• Primary winding to ground
• Filament winding to ground
1. Measure the resistance.
(Ohm-meter scale: Rx1)
• Filament terminal
2. Measure the resistance.
(Ohm-meter scale: Rx1000)
• Filament to chassis
Approx.: 0.2 ~ 0.4 ohm
Approx.: 70 ~ 100 ohm
Less than: 1 ohm
Normal: Infinite
Normal: Infinite
Normal: Less than 1 ohm
Normal: Infinite
FILAMENT
WINDING
PRIMARY
TERMINAL
COMPONENT TEST PROCEDURE
Содержание LRM1230B
Страница 27: ...DOOR CONTROL PANEL BASE PLATE OUTER CASE LATCH BOARD INTERIOR 6 1 EXPLODED VIEW INTRODUCTION ...
Страница 28: ...6 2 13552A 13213A 13581A 14970A 14026A 13536A 15006A 13720D 13352A DOOR PARTS ...
Страница 29: ...6 3 24781M 23506A 23572A 24510L 24970A 250201 268711 WTP018 CONTROLLER PARTS ...
Страница 30: ...6 4 33390G WTT010 WTT020 WSZ185 33112U 35889A 36549S WTP013 33052A 948502 OVEN CAVITY PARTS ...
Страница 31: ...6 5 WSZ085 466001 466003 466001 43500A LATCH BOARD PARTS ...
Страница 33: ...6 7 56170D WSZ002 WTT021 63302A 65006B 63303A BASE PLATE PARTS ...
Страница 38: ...8 1 SCHEMATIC DIAGRAM OF P C B ...
Страница 39: ...8 2 PRINTED CIRCUIT BOARD ...
Страница 42: ...P NO 3828W5S3026 Mar 2002 Printed in China ...