A. PRIMARY INTERLOCK SWITCH TEST
When the door release button is depressed slowly
with the door closed, an audible click should be
heard at the same time or successively at
intervals. When the button is released slowly, the
latches should activate the switches with an
audible click.
If the latches do not activate the switches when
the door is closed, the switches should be a
adjusted in accordance with the adjustment
procedure. Disconnect the wire lead from the
primary switch. Connect the ohmmeter leads to
the common (COM) and normally open (NO)
terminal of the switch. The meter should indicate
an open circuit in the door open condition.
When the door is closed, the meter should
indicate a closed circuit.
When the primary switch operation is abnormal,
make the necessary adjustment or replace the
switch only with the same type of switch.
B. SECONDARY INTERLOCK SWITCH TEST
Disconnect the wire lead from the secondary
switch.
Connect the ohmmeter leads to the common
(COM) and normally open (NO) terminals of the
switch. The meter should indicate a open circuit in
the door open condition. When the door is closed,
meter should indicate an closed circuit. When the
secondary switch operation is abnormal, make the
necessary adjustment or replace the switch only
with the same type of switch.
C. MONITOR SWITCH TEST
Disconnect the wire lead from the monitor switch.
Connect the ohmmeter leads to the common
(COM) and normally closed (NC) terminals of the
switch. The meter should indicate closed circuit in
the door open condition. When the door is closed,
meter should indicate an open circuit. When the
monitor switch operation is abnormal, replace with
the same type of switch.
NOTE: After repairing the door or the interlock
system, it is necessary to do this continuity
test before operating the oven.
5-7
WARNING : FOR CONTINUED PROTECTION AGAINST EXCESSIVE RADIATION
EMISSION, REPLACE ONLY WITH IDENTICAL REPLACEMENT PARTS.
TYPE NO. SZM-V 16-FA-63 OR VP-533A-OF OR V-5230Q FOR PRIMARY SWITCH
TYPE NO. SZM-V 16-FA-62 OR VP-532A-OF OR V-5220Q FOR MONITOR SWITCH
TYPE NO. SZM-V 16-FA-63 OR VP-533A-OF OR V-5230Q FOR SECONDARY SWITCH
COMPONENTS
TEST PROCEDURE
RESULTS
SWITCHES
Check for continuity of the
Door
Door
(Wire leads removed)
switch with an Ohm-meter
open
closed
Primary
Switch
Monitor
Switch
Secondary
Switch
NOTE : After checking for the continuity of switches, make sure that they are
connected correctly.
NO
COM
NC
COM
NO
COM
INTERLOCK CONTINUITY TEST
Содержание LRM1230B
Страница 27: ...DOOR CONTROL PANEL BASE PLATE OUTER CASE LATCH BOARD INTERIOR 6 1 EXPLODED VIEW INTRODUCTION ...
Страница 28: ...6 2 13552A 13213A 13581A 14970A 14026A 13536A 15006A 13720D 13352A DOOR PARTS ...
Страница 29: ...6 3 24781M 23506A 23572A 24510L 24970A 250201 268711 WTP018 CONTROLLER PARTS ...
Страница 30: ...6 4 33390G WTT010 WTT020 WSZ185 33112U 35889A 36549S WTP013 33052A 948502 OVEN CAVITY PARTS ...
Страница 31: ...6 5 WSZ085 466001 466003 466001 43500A LATCH BOARD PARTS ...
Страница 33: ...6 7 56170D WSZ002 WTT021 63302A 65006B 63303A BASE PLATE PARTS ...
Страница 38: ...8 1 SCHEMATIC DIAGRAM OF P C B ...
Страница 39: ...8 2 PRINTED CIRCUIT BOARD ...
Страница 42: ...P NO 3828W5S3026 Mar 2002 Printed in China ...