-26-
MEASUREMENT WITH THE OUTER
CASE REMOVED
(1) When you replace the magnetron, measure for
microwave energy leakage before the outer case
is installed and after all necessary components
are replaced or adjusted. Special care should be
taken in measuring the following parts.
-Around the magnetron
-The waveguide
WARNING:
AVOID CONTACTING ANY HIGH
VOLTAGE PARTS.
MEASUREMENT WITH A FULLY
ASSEMBLED OVEN
(1) After all components, including the outer
panels, are fully assembled, measure for
microwave energy leakage around the door
viewing window, the exhaust opening and air
inlet openings.
(2) Microwave energy leakage must not exceed the
values prescribed below.
NOTES:
Leakage with the outer panels removed
than 5 mW/cm
2
.
Leakage for a fully assembled oven (Before the
latch switch (primary) is interrupted) with the
door in a slightly opened position - less than 1
mW/cm
2
NOTE WHEN MEASURING
(1) Do not exceed meter full scale deflection.
(2) The test probe must be removed no faster than
1 inch/sec (2.5cm/sec) along the shaded area,
otherwise a false reading may result.
(3) The test probe must be held with the grip portion
of the handle. A false reading may result if the
operator’s hand is between the handle and the
probe.
(4) When testing near a corner of the door, keep
the probe perpendicular to the surface making
sure the probe horizontally along the oven
surface, this may possibly cause probe damage.
RECORD KEEPING AND NOTIFICATION
AFTER MEASUREMENT
(1) After adjustment and repair of any microwave
energy interruption or microwave energy
blocking device, record the measured values for
future reference. Also enter the information on
the service invoice.
(2) Should the microwave energy leakage not be
more than 1 mW/cm
2
after determining that all
parts are in good condition, functioning properly
and genuine replacement parts which are listed
in this manual have been used.
(3) At least once a year, have the electromagnetic
energy leakage monitor checked for calibration
by its manufacturer.
Содержание LMV2015SB
Страница 7: ... 7 4 OPERATION 4 1 Control Panel Features ...
Страница 9: ...5 WIRING DIAGRAM KEY MATRIX 9 5 1 Wiring Diagram ...
Страница 14: ... 14 6 4 Troubleshooting No Display or Dead ...
Страница 17: ... 17 Keypad Failure MICOM Start key or EZ ON key works if the door is closed ...
Страница 19: ... 19 No Heat No Cook ...
Страница 43: ...12 EXPLODED VIEW 43 DOOR PARTS I 1005 1384 1000 1002 1004 1006 1007 1009 W109 W109 W136 EV FOR MODELS ...
Страница 44: ... 45 CONTROLLER PARTS I CONTROLLER PARTS I 2004 2000 2002 2008 2006 W130 MBM2 EV FOR MODELS ...
Страница 46: ... 48 LATCH BOARD PARTS W102 4000 4002 4003 4001 4004 4002 EV ...
Страница 48: ...INTERIOR PARTS II 3027 5117 5011 5021 5460 5006 5037 3047 5014 W109 W109 W109 W107 5117 5074 5206 5015 5038 50 ...
Страница 50: ......