-12-
A. SINCE NEARLY 4,000 VOLTS EXISTS IN
SOME CIRCUITS OF THIS UNIT REPAIRS
SHOULD BECARRIED OUT WITH GREAT
CARE.
The filament leads of magnetron carry High
Voltage with respect to ground. Extreme caution
must be exercised. Never plug the unit into a
power source to determine which component is
defective in high voltage section.
B. TO AVOID POSSIBLE EXPOSURE TO
MICROWAVE ENERGY LEAKAGE, THE
FOLLOWING PRECAUTIONS MUST BE TAKEN
BEFORE SERVICING.
(1) Before the power is applied:
(a) Make sure the primary interlock switch, the
secondary interlock switch and the interlock
monitor switch operate properly by opening
and closing the door several by opening and
closing the door several times.
(b) Make sure the perforated screen and the
dielectric choke of the door are correctly and
firmly mounted.
(2) After power is applied:
(a) Make sure the interlock switch mechanism
is operating properly by opening and closing
the door.
(b) Check microwave energy leakage must be
below the limit of 5 mW/cm
2
.
(All service adjustments should be made for
minimum microwave energy leakage
readings).
(3) Do not operate the unit until it is completely
repaired, if any of the following conditions exist.
The unit must not be operated.
(a) The door does not close firmly.
(b) The hinge is broken.
(c) The door seal is damaged.
(d) The door is bent or warped, or there is any
other visible damage on the unit that may
cause microwave energy leakage.
NOTE:
Always keep the seal clean.
(e) Make sure that there are no defective parts
in the interlock mechanism.
(f) Make sure that there are no detective parts
in the microwave generating and
transmission assembly (especially
waveguide).
(4) The following items should be checked after the
unit is repaired:
(a) The interlock monitor switch is connected
correctly and firmly.
(b) The magnetron gasket is properly positioned
and mounted.
(c) The waveguide and the oven cavity are
intact.
(no microwave energy leakage)
(d) The door can be properly closed and the
safety switches work properly.
(e) The unit must stop when the door is opened
or the time is up.
The unit must not be operated with any of the above
components removed or bypassed.
6-2. Safety Caution
Содержание LMV2015SB
Страница 7: ... 7 4 OPERATION 4 1 Control Panel Features ...
Страница 9: ...5 WIRING DIAGRAM KEY MATRIX 9 5 1 Wiring Diagram ...
Страница 14: ... 14 6 4 Troubleshooting No Display or Dead ...
Страница 17: ... 17 Keypad Failure MICOM Start key or EZ ON key works if the door is closed ...
Страница 19: ... 19 No Heat No Cook ...
Страница 43: ...12 EXPLODED VIEW 43 DOOR PARTS I 1005 1384 1000 1002 1004 1006 1007 1009 W109 W109 W136 EV FOR MODELS ...
Страница 44: ... 45 CONTROLLER PARTS I CONTROLLER PARTS I 2004 2000 2002 2008 2006 W130 MBM2 EV FOR MODELS ...
Страница 46: ... 48 LATCH BOARD PARTS W102 4000 4002 4003 4001 4004 4002 EV ...
Страница 48: ...INTERIOR PARTS II 3027 5117 5011 5021 5460 5006 5037 3047 5014 W109 W109 W109 W107 5117 5074 5206 5015 5038 50 ...
Страница 50: ......