background image

07

Parallel Connection

The solar modules may be combined in parallel to

produce the desired current output.

When modules are combined in parallel, the total

current is equal to the sum of currents from each

module.

The voltage of each module connected in parallel

should be the same.

When connecting plural strings of modules in parallel

every series string or solar module must be fused prior

to combining with other strings.

Abide with all applicable federal, state, and local codes

for additional fusing requirements and limitations on

the maximum number of solar modules in parallel.

Maximum series fuse rating is refer to “Product

for the protection of the module and cables from over-

current for prevention of unbalanced string voltage.

A multiplying factor is required for increased output

of the PV modules. Under normal conditions, a PV

module is likely to experience conditions that produce

more current and/or voltage than reported at standard

test conditions. The requirements of the National

Electrical Code (NEC) in Article 690 shall be followed

to address these increased outputs. In installations

not under the requirements of the NEC, the values

of Isc and Voc marked on this PV module should

be multiplied by a factor of 125% when determining

component voltage ratings, conductor ampacities,

fuse sizes, and size of controls to the PV output.

Depending on national directives, additional safety

factors might be applicable for over current protection.

Earth Grounding 

All work must be conducted in conformance with all
Federal, State, and local codes and standards.

Grounding works should be performed by an
authorized installer for the safety and maintenance of
the system in accordance with all national, state and
local electrical codes and regulations and standards.

and location of grounding holes is provided in “Product

One M4 stainless steel bolt, one nut, one spring

washer and 12 AWG Cu wires are recommended per
mounting hole.

Where common grounding hardware (nut, bolts,
washers) is used to attach a listed grounding device,
the attachment must be made in conformance with the
grounding device manufacturer’s instructions.

All hardware should be consist of corrosion resistant
material such as stainless steel.

There is an earth hole on the edge of the module
frame. Using this hole, an earth conductor and the
solar module frame may be recommended to be
connected and earthed as the below drawing.

All screws and nuts shall be tightened to a torque of

To prevent electric shock and fire, a protective ground
must be done on the frames of solar modules and arrays

safety class II. The national directives must be respected.

although the solar modules from LG meet the conditions of

4~5 N∙m.

Module frame

Bolt

Flat washer
Star washer

Cup washer

Grounding wire

Spring washer

Nut

Flat washer

Specifications; page 11”.

Parallel configuration is not limited if proper measures

are taken to block the reverse current flow, e.g. fuses

Parallel connection for more current

-

+

…………

+

-

+

-

-

+

-

+

General Wiring

LG Electronics recommends that all wiring be double

insulated with a minimum rating of 90°C (194°F).


The minimum size should be determined by the

applicable codes.

LG Electronics recommends a size no smaller than

4mm  .

2

All wiring should use a flexible copper (Cu) conductor.

Specific information on the solar module dimensions

Specifications”.

washer, two flat washers, one cup washer, one star

Содержание LG425N2T-E6

Страница 1: ...Please read this manual carefully before operating your set and retain it for future reference N TYPE MODELS LGXXXN2W E6 LGXXXN2W E6 AW5 LGXXXN2T E6 www lg solar com Installation manual PV Solar MODULE ...

Страница 2: ...onnection 07 General Wiring 07 Earth Grounding 07 MECHANICAL INSTALLATION 08 Module Mounting 08 Site Consideration 08 Mounting Methods 08 DISCLAIMER OF LIABILITY DISPOSAL 10 TRANSPORTING AND STORAGE 10 REVISIONS TABLE 10 PRODUCT SPECIFICATIONS 11 Electrical Mechanical Properties 11 Dimensions of Modules 13 Mechanical Installation methods Bolting Clamp Information Unloading Flow Guide 14 16 17 APPE...

Страница 3: ...ed modules must be treated with safety protection equipment Failure to comply may result in serious bodily injury or death No electrical parts like cables are located after installation between laminate and mounting structure Do Not reconnect or repair junction box cable It may occur spark or electric shock Do not bending junction box s cable While under stress it may occur module damage Cable ben...

Страница 4: ...the junction box of the module or pull the cable Do not remove the labels attached to the module Failure to comply may result in damage of the product If the installing modules on curved surface e g arch type as shown in the below picture do not forcefully modify the module in the installation when connecting it with the structure Only install the module in the place where the structure for the pa...

Страница 5: ...icro fiber cloth can be used for regular washing or It may result in a burn or injury Do not disassemble the solar module After installation or repair check that the solar module are operating properly In the event that the currently used solar module or parts have been replaced the newly replaced module and parts must have the same model name and parts as the previously installed solar module Do ...

Страница 6: ... connections Modules may be connected in series and or parallel to achieve the desired electrical output as long as it sheet Please use only the same type of modules in a combined source circuit Do not disconnect the module under when it is operating Shock hazard may occur near the solar modules connection means When the module installing in series or in parallel e g using for extension cables etc...

Страница 7: ...rks should be performed by an authorized installer for the safety and maintenance of the system in accordance with all national state and local electrical codes and regulations and standards and location of grounding holes is provided in Product One M4 stainless steel bolt one nut one spring washer and 12 AWG Cu wires are recommended per mounting hole Where common grounding hardware nut bolts wash...

Страница 8: ... is no shadowing affected by building chimney tree and neighboring module etc Mounting Rails No of Cell Do not use module to replace or partly replace roofs and walls of living places Mounting Methods General Information Select the appropriate orientation to maximize sunlight exposure The module generates maximum output power when it faces the sun directly The tilt angle of the modules should be s...

Страница 9: ...ch module should be securely fastened at a minimum 4 points on two opposite sides and location of mounting holes is provided in Product Tighten the bolt securely by using the combination Place the spring washer between the Flat washer and Nut Mounting by using clamps The module may be fastened to a support by using clamps on both the long edge and the short edge of the modules provided in Mechanic...

Страница 10: ...the environment and human health Your old appliance may contain reusable parts that could be used to repair other products and other valuable materials that can be recycled to conserve limited resources 3 You can take your appliance either to the shop where you purchased the product or contact your local government waste office for details of your nearest authorized WEEE collection point For the m...

Страница 11: ...2 40 LG450N2W E6 AW5 450 0 3 24 20 1500 2110 1042 40 LGXXXN2W E6 AW5 LGXXXN2T E6 MC4 05 8 PV CO02 MC4 05 8 PV CO02 MC4 05 8 PV CO02 MC4 05 8 PV CO02 MC4 05 8 PV CO02 MC4 05 8 PV CO02 MC4 05 8 PV CO02 MC4 05 8 PV CO02 MC4 05 8 PV CO02 MC4 05 8 PV CO02 MC4 05 8 PV CO02 MC4 05 8 PV CO02 MC4 05 8 PV CO02 MC4 05 8 PV CO02 MC4 05 8 PV CO02 MC4 05 8 PV CO02 MC4 05 8 PV CO02 MC4 05 8 PV CO02 MC4 05 8 PV C...

Страница 12: ...325 38 7 8 39 46 3 8 81 435 328 39 0 8 42 46 6 8 86 440 332 39 3 8 46 46 9 8 91 MPP Voltage Vmpp V MPP Current Impp A Open Circuit Voltage Voc V Short Circuit Current Isc A Temperature Characteristics PRODUCT SPECIFICATIONS NMOT Nominal Module Operating Temperature Irradiance 800W m ambient temperature 20 wind speed 1m s 2 12 42 3 0 33 0 26 0 04 LGXXXN2W E6 Model 430 Maximum Power Pmax W 325 38 2 ...

Страница 13: ...13 Dimensions of Modules LGXXXN2W E6 LGXXXN2W E6 AW5 LGXXXN2T E6 Unit mm in Note Cable length with connector MC4 05 8 PV CO02 Note Cable length with connector MC4 05 8 PV CO02 ...

Страница 14: ... Position mm 250 400 5400 3000 Load Front Rear Pa Position mm 0 300 5400 1600 Load Front Rear Pa Position mm 0 50 100 750 2400 2400 A B Fig 1 Bolting type M8 Fig 2 Clamping Type Fig 4 Clamping Type Fig 5 Clamping Type Fig 6 Clamping Type Mechanical Installation 72Cell Model Load Front Rear Pa Position mm N2W 343 N2T 353 5400 3000 Fig 3 Clamping Type ...

Страница 15: ...2400 1500 1500 A Load Front Rear Pa Position mm 0 300 250 400 2400 1600 A B Load Front Rear Pa Position mm 0 50 100 750 2400 2400 A B Load Front Rear Pa Position mm 250 400 3000 3000 Fig 10 Bolting type M6 Fig 7 Clamping Type Fig 8 Clamping Type Fig 9 Clamping Type APPENDIX Mechanical Installation 72Cell Model 853 ...

Страница 16: ...our spring washers and eight flat washers are recommended per solar module Bolting Method Clamp system requirements Use corrosion resistant material clamps and hardware E G L y b y t i l i b i t a p m o c r o f t s e t o t s d e e n t i p m a l c l a i c e p s a e s u u o y f I The clamp should not be touched with the module s glass Use appropriate bolted connections as per clamp manufacturer s in...

Страница 17: ... Block Standard Line Rope The position of rope have to be between block 1 and block 2 when you fasten a rope to pallet If you have not timber bar you can use a pallet which is longer than module size The crane hook have to be placed center of packaging For the balance of packaging the rope between the packaging and crane must be the same length Step 3 Loading unloading packaging A minimum of two o...

Страница 18: ...ea Contact solarinfo lge com http www lg solar com LG Electronics Deutschland GmbH Alfred Herrhausen Allee 3 5 65760 Eschborn Germany Contact service solar lge de LG LG logo and Life s Good are trademarks of LG Electronics Inc worldwide Trademarks and intellectual properties of LG Electronics Inc are protected by international copyright laws ...

Отзывы: