- Electrical Connections
Modules may be connected in series and/or parallel to achieve the desired electrical output as long as
certain requirements are met. Please use only the same type of modules in a combined source circuit.
Never direct artificially concentrated light on to the module.
Do not disconnect the module under load.
Shock hazard shall be applied near the means of connection to the modules.
- General Wiring
LG Electronics recommends that all wiring be double insulated with a minimum rating of 90°C (194°F).
All wiring should use a flexible copper (Cu) conductor.
The minimum size should be determined by the applicable codes.
We recommend a size not smaller than 4mm
2
.
- Earth Ground Wiring
To prevent electric shock and fire, an earth ground must be done on the frames of Photovoltaic(solar
modules) modules and arrays. There is an earth hole in the center of the module frame. Using this hole,
an earth conductor and the solar module frame must be connected and earthed.
4. Electrical Installation
Page 6
- Series Connection
The solar modules may be wired in series to produce the desired voltage output.
Do not exceed the maximum system voltage.
- SERIES for more voltage -