• Do not cool excessively indoors. This may be harmful for your health and may consume more

electricity.

• Block sunlight with blinds or curtains while you are operating the air conditioner.

• Keep doors or windows closed tightly while you are operating the air conditioner.

• Adjust the direction of the air flow vertically or horizontally to circulate indoor air.

• Speed up the fan to cool or warm indoor air quickly, in a short period of time.

• Open windows regularly for ventilation as the indoor air quality may deteriorate if the air 

conditioner is used for many hours.

• Clean the air filter once every 2 weeks. Dust and impurities collected in the air filter may block the

air flow or weaken the cooling / dehumidifying functions.

For your records

Staple your receipt to this page in case you need it to prove the date of purchase or for warranty

purposes. Write the model number and the serial number here:

Model number :

Serial number :

You can find them on a label on the side of each unit.

Dealer’s name :

Date of purchase :

Here are some tips that will help you minimize the power consumption when you use the air

conditioner. You can use your air conditioner more efficiently by referring to the instructions

below:

TIPS FOR SAVING ENERGY

- Otherwise, the expansion valve or capillary tube may become blocked with contaminants.

• For R410A model, use piping, flare nut and tools which is specified for R410A refrigerant.

- Using of (R22) piping, flare nut and tools may cause abnormally high pressure in the refrigerant

cycle (piping), and possibly result in explosion and injury.

• It is desirable that the amount of residual oil less than 40 mg/10m.

Operation

• Do not share the outlet with other appliances.

- It will cause an electric shock or a fire due to heat generation.

• Do not use the damaged power cord.

- Otherwise, it may cause a fire or electrical shock.

• Do not modify or extend the power cord randomly.

- Otherwise, it may cause a fire or electrical shock.

• Take care so that the power cord may not be pulled during operation.

- Otherwise, it may cause a fire or electrical shock.

• Unplug the unit if strange sounds, smell, or smoke comes from it.

- Otherwise, it may cause electrical shock or a fire.

• Keep the flames away.

- Otherwise, it may cause a fire.

• Take the power plug out if necessary, holding the head of the plug and do not touch it with wet

hands.
- Otherwise, it may cause a fire or electrical shock.

• Do not use the power cord near the heating tools.

- Otherwise, it may cause a fire and electrical shock.

• Do not open the suction inlet of the indoor/outdoor unit during operation.

- Otherwise, it may electrical shock and failure.

• Do not allow water to run into electrical parts.

- Otherwise, it may cause the failure of machine or electrical shock.

• Hold the plug by the head when taking it out.

- It may cause electric shock and damage.

• Never touch the metal parts of the unit when removing the filter.

- They are sharp and may cause injury.

• Do not step on the indoor/outdoor unit and do not put anything on it.

- It may cause an injury through dropping of the unit or falling down.

• Do not place a heavy object on the power cord.

- Otherwise, it may cause a fire or electrical shock.

Select the best Location 

Indoor unit

- There should not be any heat or steam near

the unit.

- Select a place where there are no obstacles

around of the unit.

- Make sure that condensation drainage can

be conveniently routed away.

- Do not install near a doorway.

- Ensure that the gap between a wall and the

left (or right) of the unit is more than 4in. The
unit should be installed as high as possible
on the wall, allowing a minimum of 8in from
ceiling.

- Use a metal detector to locate studs to pre-

vent unnecessary damage to the wall.

* Recommended height 6.5ft from the floor.

* The feature can be changed according to

the type of model.

More than 8

More than

4

More than

4

(Unit : in)

CAUTION

Remove obstructions to prevent blockage
of airflow path.

!

More than

12

More than

12

Sunr

oof

Fence or

obstacles

More than

28

More than

24

(Unit : in)

Outdoor unit

- If an awning is built over the unit to prevent

direct sunlight or rain exposure, make sure
that heat radiation from the condenser is not
restricted.

- Ensure that the space around the back side

and other sides is more than 12in. The space
in front of the unit should be more than 28in.

- Do not place animals and plants in the path

of the warm air.

- Take the weight of the air conditioner into ac-

count and select a place where noise and vi-
bration are minimum.

- Select a place where the warm air and noise

from the air conditioner do not disturb neigh-
bors.

INSTALLATION

IMPORTANT SAFETY INSTRUCTIONS

READ ALL INSTRUCTIONS BEFORE USING THE APPLIANCE.

Always comply with the following precautions to avoid dangerous situations and ensure peak
performance of your product.

WARNING

It can result in serious injury or death when the directions are ignored.

CAUTION

It can result in minor injury or product damage when the directions are ignored.

WARNING

• Installation or repairs made by unqualified persons can result in hazards to you and others.

• Air conditioner Shall be installed in accordance with national wiring regulations.

• If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or

similary qualified persons in order to avoid a hazard.

• The information contained in the manual is intended for use by a qualified service technician familiar

with safety procedures and equipped with the proper tools and test instruments.

• Failure to carefully read and follow all instructions in this manual can result in equipment malfunc-

tion, property damage, personal injury and/or death.

Installation

• Always perform grounding.

- Otherwise, it may cause electrical shock.

• Don’t use a power cord, a plug or a loose socket which is damaged.

- Otherwise, it may cause a fire or electrical shock.

• For installation of the product, always contact the service center or a professional installation

agency.
- Otherwise, it may cause a fire, electrical shock, explosion or injury.

• Securely attach the electrical part cover to the indoor unit and the service panel to the outdoor unit.

- If the electrical part cover of the indoor unit and the service panel of the outdoor unit are not 

attached securely, it could result in a fire or electric shock due to dust, water, etc.

• Always install an air leakage breaker and a dedicated switching board.

- No installation may cause a fire and electrical shock.

• Do not keep or use flammable gases or combustibles near the air conditioner.

- Otherwise, it may cause a fire or the failure of product.

• Ensure that an installation frame of the outdoor unit is not damaged due to use for a long time.

- It may cause injury or an accident.

• Do not disassemble or repair the product randomly.

- It will cause a fire or electrical shock.

• Do not install the product at a place that ther is concern of falling down.

- Otherwise, it may result in personal injury.

• Use caution when unpacking and installing.

- Sharp edges may cause injury.

• Thickness of copper pipes used are as shown “Flaring work” Table.

- Never use copper pipes thinner than that in the table even when it is  available on the market

• Do not use copper pipes having a collapsed. 

!

!

!

• When the product is submerged into water, always contact the service center.

- Otherwise, it may cause a fire or electrical shock.

• Take care so that children may not step on the outdoor unit.

- Otherwise, children may be seriously injured due to falling down.

CAUTION

Installation

• Install the drain hose to ensure that drain can be securely done.

- Otherwise, it may cause water leakage.

• Install the product so that the noise or hot wind from the outdoor unit may not cause any damage to

the neighbors.
- Otherwise, it may cause dispute with the neighbors.

• Always inspect gas leakage after the installation and repair of product.

- Otherwise, it may cause the failure of product.

• Keep level parallel in installing the product.

- Otherwise, it may cause vibration or water leakage.

Operation

• Avoid excessive cooling and perform ventilation sometimes.

- Otherwise, it may do harm to your health.

• Use a soft cloth to clean. Do not use wax, thinner, or a strong detergent.

- The appearance of the air conditioner may deteriorate, change color, or develop surface flaws.

• Do not use an appliance for special purposes such as preserving animals vegetables, precision

machine, or art articles.
- Otherwise, it may damage your properties.

• Do not place obstacles around the flow inlet or outlet.

- Otherwise, it may cause the failure of appliance or an accident.

!

Name

Quantity

Shape

Installation plate

1 EA

Type "A" screw

5 EA

Type "B" screw

2 EA

Type "C" screw

2 EA

Remote control

holder

1 EA

The feature can be changed according to a type of model.

Type "D" screw

Bracket

2 EA

1 EA

Screws for fixing panels are attached to decoration panel.

Figure

Figure

Name

Screw driver

Electric drill

Measuring tape, Knife

Hole core drill

Spanner

Torque wrench

Multi-meter

Hexagonal wrench

Ammeter

Gas-leak detector

Thermometer, 

Level

Flaring tool set

Name

INSTALLATION TOOLS

INSTALLATION PARTS

Drill a Hole in the Wall

- Drill the piping hole with a ø65mm hole core

drill. Drill the piping hole at either the right or
the left with the hole slightly slanted to the
outdoor side.

Flaring Work

Main cause for gas leakage is due to defect of
flaring work. Carry out correct flaring work in
the following procedure.

Cut the pipes and the cable

1

Use the piping kit accessory or the pipes
purchased locally.

2

Measure the distance between the indoor
and the outdoor unit.

3

Cut the pipes a little longer than measured
distance.

4

Cut the cable 1.5m longer than the pipe
length.

5-7mm

(3/16"~5/16")

Indoor

WALL

Outdoor

Copper

pipe

90°

Slanted   Uneven  Rough

Indoor unit

Fixing Installation Plate

The wall you select should be strong and solid
enough to prevent vibration.

1

Before installation, confirm the position of
a screw between chassis and Installation
plate.

2

Mount the installation plate on the wall
with type "A" screws. If mounting the unit
on a concrete wall, use anchor bolts.

- Mount the installation plate horizontally

by aligning the centerline using Horizontal
meter .

3

Measure the wall and mark the centerline.
It is also important to use caution concern-
ing the location of the installation plate.
Routing of the wiring to power outlets is
through the walls typically. Drilling the hole
through the wall for piping connections
must be done safely.

Ø65

A Type : 95

B Type : 170

A Type : 133

B Type : 123

A Type B Type

Right rear piping

Left rear piping

Place a level on raised tab

Unit
Outline

217

175

(Unit : mm)

A Type : 442

B Type : 434

A Type : 442

B Type : 439

Ø65

Ø65

Ø65

Installation Plate

Installation Plate

Installation Plate

Chassis

Hook

Type "A" Screws

A-Type

B-Type

Connecting cable
(Optional Parts) 

Gas side piping       (Optional Parts)
Liquid side piping       (Optional Parts)
Additional drain pipe

Vinyl tape (Narrow)
Drain Hose

Vinyl tape (Wide)

• Apply after carrying out a
  drainage test.
• To carry out the drainage 
  test, remove the air filters
  and pour water into the heat 
  exchanger.

Saddle

Installation plate

Sleeve
Bushing-Sleeve
Putty(Gum Type Sealant)

Bend the pipe as closely 
on the wall as possible, 
but be careful that it 
doesn't break.

NOTE

!

• You should purchase the installation parts.

* The feature can be changed according to a type of model.

INSTALLATION MAP

Burrs removal

1. Completely remove all burrs from the cut

cross section of pipe/tube.

2. While removing burrs put the end of the

copper tube/pipe in a downward direction
while removing burrs location is also
changed in order to avoid dropping burrs
into the tubing.

Putting nut on

- Remove flare nuts attached to indoor and

outdoor unit, then put them on pipe/tube
having completed burr removal.
(not possible to put them on after finishing
flare work)

Flaring work

1

Firmly hold copper pipe in a bar with the di-
mension shown in the table below .

2

Carry out flaring work with the flaring tool.

Pipe

Reamer

Point down

Flare nut

Copper tube

Inclined

Inside is shiny without scratches

Smooth all round

Even length

all round

Surface

damaged

Cracked Uneven

thickness

= Improper flaring =

Check

1

Compare the flared work with the figure
by.

2

If a flared section is defective, cut it off
and do flaring work again.

Connecting the Piping

1

Open the panel of the indoor unit.

2

Remove the chassis cover from the unit by
loosing 3 screws.

Chassis cover

Bar

Copper pipe

Clamp handle

Red arrow mark

Cone

Yoke

Handle

Bar

"A"

Outside diameter

A

Thickness

mm

inch

mm

mm

Ø6.35

1/4"

1.1~1.3

0.7

Ø9.52

3/8"

1.5~1.7

0.8

Ø12.7

1/2"

1.6~1.8

0.8

Ø15.88

5/8"

1.6~1.8

1.0

Installation of Indoor Unit

1

Hook the indoor unit onto the upper por-
tion of the installation plate.( engage the
three hooks at the top of the indoor unit
with the upper edge of the installation
plate) Ensure that the hooks are properly
seated on the installation plate by moving
it left and right.

2

Unlock the tubing holder from the chassis
and mount between the chassis and instal-
lation plate in order to separate the bottom
side of the indoor unit from the wall.

* The feature can be changed according to a

type of model.

Piping

1

Raise the cover of terminal block.

2

Insert the connecting cable through the
bottom side of indoor unit and connect the
cable. (You can see detail contents in ‘Con-
necting  the cables’ section.)

<Left side piping>

Cover

View

Cable retainer

Terminal block
Connecting cable

Installation plate

Tubing Holder

<Right side piping>

3

Secure the cable onto the control board
with the cable retainer.

4

Close the cover of control box.

5

Tape the tubing pipe, drain hose and the
conduit. Be sure that the drain hose is lo-
cated at the lowest side of the bundle.
Locating at the upper side can cause over-
flow from the drain pan through the inside
of the unit.

View

Cover

Cable retainer

Terminal block
Connecting cable

<Left side piping>

<Right side piping>

* The feature can be changed according to a

type of model.

Connecting pipe 

Conduit

Tape

Drain hose

Drain hose

Connecting pipe 

Tape

Conduit

Drain hose

NOTE

!

Insert the drain hose at left side when
you use left side piping type. 

Finishing the indoor unit 
installation

1

Mount the tubing holder in the original
positon.

2

Ensure that the hooks are properly seated
on the installation plate by moving it left
and right.

3

Press the lower left and right sides of the
unit against the installation plate until the
hooks engage into their slots (clicking
sound).

4

Finish the assembly by screwing the unit
to the installation plate by using two pieces
of type "C" screws. And assemble a chas-
sis cover.

Type 'C' screw

3

Bundle the piping and drain hose together
by wrapping them with vinyl tape sufficient
enough to cover where they fit into the
rear piping housing section.

Vinyl tape(narrow)

Connection pipe

Connecting cable

Vinyl tape (wide)

Wrap with vinyl tape

Indoor unit pipe

Pipe

Wrap with vinyl tape

Drain hose

Pipe

Vinyl tape(wide)

CAUTION

• Before finishing installation of the indoor

unit, seal the hole of a wall except the
pipe’s ways to prevent condensate from
inflow of outdoor air.

!

Outdoor unit

Connecting the Piping

- Remove the tubing cover from the unit by

loosening the screw.

- Align the center of the pipings and suffi-

ciently tighten the flare nut by hand.

Tubing cover

The power cord connected to the outdoor
unit should be complied with the follow-
ing specifications(UL recognized or CAS
certified)

10±3mm

20mm

GN/YL

AWG_“A”

Terminal block

Connecting
cable

Power
supply
cord

Conduit panel

Tubing cover

Over 5mm

(0.2")

 

Air 

Conditioner

Main power source

Circuit Breaker
Use a circuit breake
or time delay fuse.

10±3mm

20mm

GN/YL

AWG_“B”

The power connecting cable connected to the
indoor and outdoor unit should be complied
with the following specifications (UL recog-
nized or CAS certified).

* Field wiring shall be done such that the cur-

rentcarrying conductors become taut before
the earthing conductor if the cord slips out
of the cord anchorage.

- Connect the wires to the terminals on the

control board individually.

- Secure the cable onto the control board with

the cord clamp.

- Use a recognized circuit breaker between

the power source and the unit.
A disconnecting device to adequately discon-
nect all supply lines must be fitted.

- Provide a circuit breaker between power

source and the outdoor unit as shown below.

CAUTION

When using the separate wire as the
power cord, please fix the separate wire
into the control box panel by using tie
wrap as the fixture. "A" & "B" are minimum
recommended wire size. 

!

CAUTION

!

Circuit

Breaker

(A)

Capacity(Btu/h)

9k~12k

15

Power

Capacity(Btu/h)

9k/12k

"B"

18

Power

Capacity(Btu/h)

9k/12k

"A"

14

3

Pull back the tubing holder.

4

Remove pipe port  cover and positioning
the tubing

* The feature can be changed according to a

type of model.

Good case

-  Press on the tubing cover and unfold the

tubing to downward slowly. And then bend
to the left side slowly.

Right

Tubing holder

Downwards

Left

Backwards

Indoor unit back side view

CAUTION

Installation Information. For right piping.
Follow the instruction above.

!

Bad case

- Following bending case from right to left di-

rectly may cause damage to the tubing.

* The feature can be changed according to a

type of model.

- Before bending the tubing, set the conduit

like picture below by using the bracket and
black screws from accessory kit.

Indoor unit tubing

Flare nut Pipes

Connecting the installation pipe
and drain hose to the indoor unit.

1

Align the center of the pipes and suffi-
ciently tighten the flare nut by hand

2

Tighten the flare nut with a wrench

3. When needed to extend the drain hose of

indoor unit, assembly the drain pipe as
shown on the drawing

Wrench

Indoor unit tubing

Open-end wrench

(fixed)

Connection

pipe

Flare nut

Vinyl tape(narrow)

Adhesive

Drain pipe

Indoor unit drain hose

Wrap the insulation material
around the connecting portion.

1

Overlap the connection pipe insulation ma-
terial and the indoor unit pipe insulation
material. Bind them together with vinyl
tape so that there may be no gap.

2

Set the tubing cutting line upward. 
Wrap the area which accommodates the
rear piping housing section with vinyl tape.

Insulation material

Gas Pipe 

Liquid Pipe 

Cutting Line 

Cutting Line

Good Case 

Bad Case 

* Tubing cutting line have to be upward. 

CAUTION

If the drain hose is routed inside the room
insulate the hose with an insulation mate-
rial* so that dripping from sweating (con-
densation) will not damage furniture or
floors.

* Foamed polyethylene or equivalent is

recommended.

!

CAUTION

Must use the elbow type
(L-Type) conduit

Method: 

1. Disassemble bracket

(from indoor unit) 

2. Assemble it with conduit 

3. Reassemble it with

indoor unit..

!

Outside Diameter

Torque

mm

inch

kgf·cm

N·m

Ø6.35

1/4

180~250 17.6~24.5

Ø9.52

3/8

340~420 33.3~41.2

Ø12.7

1/2

550~660 53.9~64.7

Ø15.88

5/8

630~820 61.7~80.4

Connecting the Cables

Connect the cable to the indoor unit by con-
necting the wires to the terminals on the con-
trol board individually according to the outdoor
unit connection. (Ensure that the color of the
wires of the outdoor unit and the terminal No.
are the same as those of the indoor unit.)

- Finally, tighten the flare nut with torque

wrench until the wrench clicks.
When tightening the flare nut with torque
wrench, ensure the direction for tightening
follows the arrow on the wrench.

Outdoor unit 

Gas side piping

(Bigger diameter)

Liquid side piping

(Smaller diameter)

Torque wrench

CAUTION

- The circuit diagram is a subject to

change without notice. 

- The earth wire should be longer than the

common wires.

- When installing, refer to the circuit dia-

gram on the chassis cover.

- Connect the wires firmly so that they

may not be pulled out easily.

- Connect the wires according to color

codes, referring to the wiring diagram.

!

Outside Diameter

Torque

mm

inch

kgf·cm

N·m

Ø6.35

1/4

180~250 17.6~24.5

Ø9.52

3/8

340~420 33.3~41.2

Ø12.7

1/2

550~660 53.9~64.7

Ø15.88

5/8

630~820 61.7~80.4

CAUTION

According to the confirmation of the
above conditions, prepare the wiring as
follows.

1

Never fail to have an individual power
circuit specifically for the air condi-
tioner. As for the method of wiring, be
guided by the circuit diagram posted
on the inside of control cover.

2

The screw which fasten the wiring in
the casing of electrical fittings are li-
able to come loose from vibrations to
which the unit is subjected during the
course of transportation. Check them
and make sure that they are all tightly
fastened. (If they are loose, it could
cause burn-out of the wires.)

3

Specification of power source.

4

Confirm that electrical capacity is suffi-
cient.

5

See that the starting voltage is main-
tained at more than 90 percent of the
rated voltage marked on the name
plate.

6

Confirm that the cable thickness is as
specified in the power source specifi-
cation.
(Particularly note the relation between
cable length and thickness.

7

Always install an earth leakage circuit
breaker in a wet or moist area.

8

The following would be caused by volt-
age drop.

- Vibration of a magnetic switch, which

will damage the contact point, fuse
breaking, disturbance of the normal
function of the overload.

9

The means for disconnection from a
power supply shall be incorporated in
the fixed wiring and have an air gap
contact separation of at least 3mm in
each active(phase) conductors.

!

Drain piping

1

The drain hose should point downward for
easy drain flow.

Downward slope

Checking the Drainage

To check the drainage.

1

Pour a glass of water on the evaporator.

2

Ensure the water flows through the drain
hose of the indoor unit without any leak-
age and goes out the drain exit.

Drain pan

Drain
hose

Leakage

checking

Connecting area

drain hose

Leakage

checking

1

2

3

5

4

6

7

INSTALLATION MANUAL AIR CONDITIONER

TYPE : WALL MOUNTED

P/No : MFL67502112

ENGLISH