background image

OWNER’S &

INSTALLATION MANUAL

AIR

CONDITIONER

www.lg.com

Copyright © 2017 - 2020 LG Electronics Inc. All Rights Reserved.

Please read this installation manual completely before installing the 
product. Installation work must be performed in accordance with the 
national wiring standards by authorized personnel only. This equipment shall 
be provided with a supply conductor complying with the national regulation.

Original instruction (R410A/R32)
[Representative] LG Electronics Inc. EU Representative : LG Electronics European Shared

Service Center B.V. Krijgsman 1, 1186 DM Amstelveen, The Netherlands

[Manufacturer]  LG Electronics Inc. Changwon 2nd factory 84, Wanam-ro, 
 

Seongsan-gu, Changwon-si, Gyeongsangnam-do, KOREA

This manual is the simplified version of original manual.
You can obtain the original manual from www.lg.com.

MFL70280701

Rev.08_072120

ENGLISH

IT

ALIANO

ESP

AÑOL

Содержание Hydro Kit ARNH30GK1A4

Страница 1: ...l be provided with a supply conductor complying with the national regulation Original instruction R410A R32 Representative LG Electronics Inc EU Representative LG Electronics European Shared Service Center B V Krijgsman 1 1186 DM Amstelveen The Netherlands Manufacturer LG Electronics Inc Changwon 2nd factory 84 Wanam ro Seongsan gu Changwon si Gyeongsangnam do KOREA This manual is the simplified v...

Страница 2: ...ding on the site The figures quoted are emission level and are not necessarily safe working levels Whilst there is a correlation between the emission and exposure levels this cannot be used reliably to determine whether or not further precautions are required Factor that influence the actual level of exposure of the workforce include the characteristics of the work room and the other sources of no...

Страница 3: ...erating the unit This appliance is filled with flammable refrigerant for R32 This symbol indicates that the Operation Manual should be read carefully This symbol indicates that a service personnel should be handling this equipment with reference to the Installation Manual WARNING This indicates that the failure to follow the instructions can cause serious injury or death CAUTION This indicates tha...

Страница 4: ...ng or installation may cause fire or electric shock For re installation of the installed product always contact a dealer or an Authorized Service Center There is risk of fire electric shock explosion or injury Do not install remove or re install the unit by yourself customer There is risk of fire electric shock explosion or injury Do not store or use flammable gas or combustibles near the air cond...

Страница 5: ... unit and fire or electric shock may result If the air conditioner is installed in a small room measures must be taken to prevent the refrigerant concentration from exceeding the safety limit when the refrigerant leaks Consult the dealer regarding the appropriate measures to prevent the safety limit from being exceeded Should the refrigerant leak and cause the safety limit to be exceeded hazards d...

Страница 6: ...fall onto the unit This could result in personal injury and product damage Do not open the inlet grille of the product during operation Do not touch the electrostatic filter if the unit is so equipped There is risk of physical injury electric shock or product failure Take care to ensure that power cable could not be pulled out or damaged during operation There is risk of fire or electric shock Whe...

Страница 7: ...t carrying capacity and rating Cables that are too small may leak generate heat and cause a fire Do not use the product for special purposes such as preserving foods works of art etc It is a consumer air conditioner not a precision refrigeration system There is risk of damage or loss of property Keep the unit away from children The heat exchanger is very sharp It can cause the injury such as cutti...

Страница 8: ... of pipe work shall be kept to a minimum Pipe work shall be protected from physical damage A brazed welded or mechanical connection shall be made before opening the valves to permit refrigerant to flow between the refrigerating system parts Dismantling the unit treatment of the refrigerant oil and eventual parts should be done in accordance with local and national standards Means for disconnection...

Страница 9: ...oints so that it cannot slip sideways Safely dispose of the packing materials Packing materials such as nails and other metal or wooden parts may cause stabs or other injuries Tear apart and throw away plastic packaging bags so that children may not play with them If children play with a plastic bag which was not torn apart they face the risk of suffocation Turn on the power at least 6 hours befor...

Страница 10: ...the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard Appliance shall be disconnected from its power source during service and when replacing parts This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowl...

Страница 11: ... comes in contact with the sling to prevent damage Hoist the unit making sure it is being lifted at its center of gravity CAUTION LIFTING METHOD Use two or more people to lift and transport the product INSTALLATION SPACE There should not be any heat source or steam near the unit There should not be any obstacles to the air circulation A place where air circulation in the room will be good A place ...

Страница 12: ...moved at the time of service work Never connect the main power source to terminal block of communication cable If connected electrical parts will be burnt out Use 2 core shield cable for communication cable mark in the figure below If communication cable of different systems are wired with the same multiple core cable the resultant poor transmitting and receiving will cause erroneous operations ma...

Страница 13: ...OSS SECTIONAL AREA Rated current of appliance A Nominal cross sectional area mm2 0 2 0 2 and 3 3 and 6 6 and 10 10 and 16 16 and 25 25 and 32 32 and 40 40 and 63 Tinsel cord 0 5 0 75 1 0 0 75 1 5 1 0 2 5 4 6 10 NOTE For supply cords supplied with multi phase appliances the nominal cross sectional area of the conductors is based on the maximum cross sectional area of the conductors per phase at the...

Страница 14: ...r each model type Clean the filters with a vacuum cleaner or warm soapy water If dirt is not easily removed wash with a solution of detergent in luke warm water Dry well in shade after washing and reinstall the filters back in place CAUTION Before performing any maintenance turn off the main power to the system Never use any of the followings Water hotter than 40 C Could cause deformation and or d...

Страница 15: ...r Old building New building 2 Plate washer 3 Spring washer 4 Nut 5 Suspension bolts Local supply Set anchor Plate washer M10 Spring washer M10 Nut W3 8 or M10 Suspension bolt W3 8 or M10 Minimum service space unit mm Unit mm Ceiling At least 2 500 4 000 or less 1 000 or more 500 or more 10 or more 500 or more 300 or less Floor Floor Floor 250 1 300 200 200 NOTE Self drilling screw can be used as a...

Страница 16: ... 4 8 197 70 5 214 51 5 2 232 02 5 4 250 21 5 6 269 09 5 8 288 65 6 308 90 6 2 329 84 6 4 351 46 6 6 373 77 6 8 396 76 7 420 45 7 2 444 81 7 4 469 87 7 6 495 61 7 8 522 04 Wall mounted m kg Amin m2 1 224 1 224 1 43 1 4 1 87 1 6 2 44 1 8 3 09 2 3 81 2 2 4 61 2 4 5 49 2 6 6 44 2 8 7 47 3 8 58 3 2 9 76 3 4 11 02 3 6 12 36 3 8 13 77 4 15 25 4 2 16 82 4 4 18 46 Wall mounted m kg Amin m2 4 6 20 17 4 8 21...

Страница 17: ... Anvmin At least 50 of the required opening area Anvmin shall be below 200 mm from the floor The bottom of the lowest openings shall not be higher than 100 mm from the floor If the openings starts from the floor the height must be higher than 20 mm Top opening The total size of the top opening shall not be less than 50 of minimum opening area for Anvmin and shall be at least 1 5 m above the floor ...

Страница 18: ...18 ENGLISH ...

Страница 19: ... The information for Eco design is available on the following free access website https www lg com global support cedoc cedoc ...

Отзывы: