5-9
COMPONENTS
TEST PROCEDURE
RESULTS
HIGH VOLTAGE
CAPACITOR
HIGH VOLTAGE
DIODE
NOTE :
Some inexpensive meters
may indicate infinite
resistance in both direction.
Measure the resistance.
(Ohm-meter scale: Rx1000)
• Terminal to terminal.
Measure the resistance.
(Ohm-meter scale: Rx1000)
• Terminal to case.
Measure the continuity (Forward).
(Ohm-meter scale: Rx10000)
Measure the continuity (Reverse).
(Ohm-meter scale: Rx10000)
Normal: Momentarily indicates
several ohms, and
then gradually returns
to infinite.
Normal: Infinite.
Normal: Continuity.
Abnormal: Infinite.
Normal: Infinite.
Abnormal: Continuity.
NOTE: When testing the magnetron, be sure to install the magnetron gasket
in the correct position and be sure that the gasket is in good condition.
Antenna
Gasket
Chassis
Filament
Содержание GoldStar GMS-1020TW
Страница 27: ...6 2 DOOR PARTS 13581A 13720D 13352A 13213A 13552A 15006A 13536A 14026A 14970A EV ...
Страница 28: ...6 3 24781M 23506A 23572A 23550D 24510L 24970A 250201 268711 WTP018 24930D CONTROLLER PARTS EV ...
Страница 29: ...6 4 OVEN CAVITY PARTS 33112U WTT021 WTT010 33390G 35889A WTP013 36549S 33052A EV ...
Страница 30: ...6 5 LATCH BOARD PARTS WSZ085 466001 466003 466001 43500A EV ...
Страница 32: ...6 7 56170D WTT021 63302A WSZ002 948501 WTT028 647781 63303A BASE PLATE PARTS EV ...
Страница 33: ...8 1 SCHEMATIC DIAGRAM OF P C B ...
Страница 34: ...8 2 PRINTED CIRCUIT BOARD ...
Страница 35: ......