32
5.4.1 Connecting charging cables
1. Loosen the sealing nuts of the large glands.
2. Feed charging cables through the large glands, and connect each charging cable to its
corresponding terminal. Use the terminal block at the lower left for the first battery pack,
the one at the lower right for the second battery pack, and the one at the upper for the
inverter.
3.
Tighten the sealing nuts firmly.
4.
Check if the configuration switches on the circuit board are set properly, referring to
Configuring RESU Plus on page 38
.
NOTE
Pay attention not to reverse polarity. Connection with reversed polarity causes severe
damage to the battery pack.
To connect other kinds of cables, replace the circuit board and
tighten the screws to a torque of 1 N·m. On the circuit board,
there are network ports, ground points, and terminals to supply
power to the RESU Plus for its operation.