BEFORE CALLING FOR SERVICE
(cont.)
T RO U B L E S H O OT I N G
Problem
Possible Causes
Solutions
Steam doesn’t
generate but no error
code is shown.
• Water level error.
• Unplug dryer and call for service.
Garments still
wrinkled after
Steam FreSh
™
.
• Too many or too different
types of garments in dryer.
• Small loads of 1 to 5 items work best.
• Load fewer garments. Load similar-type garments.
there are no creases
left on garment after
Steam FreSh
™
.
• The function of this cycle
is to remove wrinkles from
fabric.
• Use an iron to make creases.
Garments have
static after reDUCe
StatIC.
• This is normal.
• Depends on individual moisture level in skin.
Garments are too
damp or too dry after
reDUCe StatIC.
• Correct drying options not
selected.
• Select load weight manually before starting
REDUCE STATIC option.
Garments are not
uniformly damp after
eaSY IrON.
• This is normal.
• Depends on the amount or type of garments.
Water drips from door
during Steam Cycle.
• This is normal.
• This is steam condensation on door surface.
Steam is not visible
during Steam Cycle.
• This is normal.
• Steam vapor is difficult to see when the door is
closed.
Drum does not turn
during Steam Cycle.
• This is normal.
• The drum is turned off so that the steam vapor
remains in the drum.
Cannot see steam
vapor at the
beginning of cycle.
• This is normal.
• Steam is released at different stages of the cycle
for each option.
• MORE TIME button pressed.
Odors remain in
clothing after
Steam FreSh
™
.
• STEAM FRESH
™
did not
remove odor completely.
• Fabrics containing strong odors should be
washed in a normal cycle.
the display shows
BULKY LOaD.
• Pressing the MORE TIME button several times will
set the cycle for a large load such as a comforter.
2 bars are displayed
In the LCD screen.
• Ductwork is slightly too
long or has too many
turns/restrictions.
• Partial blockage of the
ductwork due to lint buildup.
• sInstall a shorter or straighter duct run. See the
Installation Instructions.
• Ductwork should be checked/cleaned soon.
Dryer can be used in this condition, but drying times
may be longer.
• If “END OF CYCLE” is displayed after the end of
cycle, it will be off in 4 minutes. If POWER button
is pressed or the door is opened, power will be off
immediately.
4 bars are displayed
In the LCD screen.
• Ductwork is too long or has
too many turns/restrictions.
• Significant blockage of the
ductwork due to lint buildup
or debris.
• Install a shorter or straighter duct run. See the
Installation Instructions.
• Ductwork should be checked/cleaned soon.
Dryer can be used in this condition, but drying times
may be longer.
• If “NEED FLOW CHECK” is displayed after the end
of cycle, it will be off in 2 hours. If POWER button
is pressed or the door is opened, power will be off
immediately.
END OF CYCLE
THE DUCTWORK HAS
A BLOCKAGE THAT NEEDS
TO BE REMOVED
IMMEDIATELY.
NEED FLOW CHECK
39