44
SETTING & TEST
ENGLISH
Display
Title
Cause of Error
Outdoor unit related error
2
3
1
Outdoor Unit Inverter Compressor
DC link Low Voltage
DC charging is not performed at Outdoor Unit
after starting relay turn on.
2
4
1
Outdoor Unit High Pressure Switch
System is turned off by Outdoor Unit high pres-
sure switch.
2
5
1
Outdoor Unit Input Voltage High/
Low Voltage
Outdoor Unit input voltage is over 487V or below
270V
2
6
1
Outdoor Unit Inverter Compressor
Start Failure
The First Start Failure by Outdoor Unit Inverter
Compressor Abnormality
2
8
1
Outdoor Unit Inverter DC link High
Voltage
System is turned off by Outdoor Unit DC Voltage
Over Charging
2
9
1
Outdoor Unit Inverter Compressor
Over Current
Outdoor Unit Inverter Compressor Fault OR Drive
Fault
3
2
1
Outdoor Unit Inverter Compressor
High Discharge Temperature
System is turned off by Outdoor Unit Inverter
Compressor High Discharge Temperature
3
4
1
High Pressure of Outdoor Unit
System is turned off by excessive increase of
high pressure of Outdoor Unit
3
5
1
Low Pressure of Outdoor Unit
System is turned off by excessive decrease of
low pressure of Outdoor Unit
4
0
1
Outdoor Unit Inverter Compressor
CT Sensor Fault
Outdoor Unit Inverter Compressor CT Sensor
open or short
4
1
1
Outdoor Unit Inverter Compressor
Discharge Temperature Sensor
Fault
Outdoor Unit Inverter Compressor Discharge
Temperature Sensor open or short
4
2
1
Outdoor Unit Low Pressure Sensor
Fault
Outdoor Unit Low Pressure Sensor open or short
4
3
1
Outdoor Unit High Pressure Sensor
Fault
Outdoor Unit High Pressure Sensor open or short
4
4
1
Outdoor Unit Air Temperature
Sensor Fault
Outdoor Unit Air Temperature Sensor open or
short
4
5
1
Outdoor Unit Heat Exchanger
Temperature Sensor (Front side)
Fault
Outdoor Unit Heat Exchanger Temperature
Sensor(Front side) open or short
4
6
1
Outdoor Unit Suction Temperature
Sensor Fault
Outdoor Unit Suction Temperature Sensor open
or short
Содержание B70AWYN985