background image

Room Air Conditioner

SVC MANUAL(Exploded View)

MODEL : AS-W093B1B8(LSN091HSV3 / LSU091HSV3)
 

AS-W123B1B8(LSN121HSV3 / LSU121HSV3)

CAUTION

Before Servicing the unit, read the safety precautions in General SVC manual.
Only for authorized service personnel.

Internal Use Only

http://biz.lgservice.com

Содержание AS-W093B1B8

Страница 1: ... View MODEL AS W093B1B8 LSN091HSV3 LSU091HSV3 AS W123B1B8 LSN121HSV3 LSU121HSV3 CAUTION Before Servicing the unit read the safety precautions in General SVC manual Only for authorized service personnel Internal Use Only http biz lgservice com ...

Страница 2: ...Propeller Fan Propeller Fan Motor Type BLDC BLDC Motor Output W 43 43 Circuit Breaker A 15 15 Power Supply Cable No mm2 3 1 0 3 1 0 Power and Transmission Cable No mm2 No mm2 4 1 0 Including Earth 4 1 0 Including Earth Piping Connections Liquid Side mm in 6 35 1 4 6 35 1 4 Gas Side mm in 9 52 3 8 9 52 3 8 Drain Hose O D I D mm in 21 5 16 0 0 85 0 63 21 5 16 0 0 85 0 63 Dimensions Indoor W H D mm 8...

Страница 3: ...Way Valve 2 Way Valve Liquid Side Cooling Heating Reversing Valve EEV Th1 Th4 Th5 Th2 Th3 LOC Description PCB Connector Th1 Thermistor for sunction air temperature CN TH1 Indoor Th2 Thermistor for evaporator middle temperature CN TH3 Indoor Th3 Thermistor for discharge pipe temperature CN TH2 OUTDOOR Th4 Thermistor for condensing temperature CN TH1 OUTDOOR Th5 Thermistor for outdoor air temperatur...

Страница 4: ...tronics Inc All right reserved Only for training and service purposes LGE Internal Use Only 3 Wiring Diagrams CN N CN N REMO CN N TH3 CN N TH2 CN N TH1 CN N DISP1 CN N DISP3 CN N MOTOR1 CN CC CN CC CN N U D CN N L R Indoor Unit ...

Страница 5: ...nc All right reserved Only for training and service purposes LGE Internal Use Only Safety Precautions Outdoor Unit CN U R CN V S CN W C CN FAN DC CN TH2 CN TH1 CN EEV CN 4WAY CN HEATER CN COM CN 3 WCN P L WCN P N CN E CN COIL2 CN COIL1 ...

Страница 6: ... 135313 268711B 346810 135080 135500C 147581 352150 354210 354212 249951 342800 149304 35211B 749740 135311 145200B 145200A 359011 146811B 733010 135500A W6640A 268711D 135316 263230B 268711G 267110 147582 W50400 146811A 152302B 149303 Indoor Unit LOC Description 263230B Thermistor for suction air temperature 263230A Thermistor for evaporator middle temperature ...

Страница 7: ...63230A 55211G 435513 437211 237202 435301 552203A 552203B W4986A 554160 550140 W4986B 546810 549610 W4986C 554031 435512 137213B 559010 263230C 552116B W6640 148000 W6631 552202 561410 447910 261704 553000 430410 152503 135500 552116A LOC Description 263230A Thermistor for suction air temperature Thermistor for condenser inlet temperature 263230B Thermistor for condenser outlet temperature ...

Страница 8: ... the installing contractor of your product as warranty service will be provided by them 2 If you have service issues that have not been addressed by the contractor please call 1 888 865 3026 CANADA Service call Number 888 LG Canada 888 542 2623 ...