2005 Product Data
63
8. Performance Data
Cooling
AS-H076QGA2[G07AH SQ2]
˚CWB ˚CDB
TC
SHC
PI
TC
SHC
PI
TC
SHC
PI
TC
SHC
PI
TC
SHC
PI
TC
SHC
PI
14
20
1.7
1.3
0.5
1.6
1.3
0.6
1.6
1.2
0.7
1.5
1.2
0.7
1.4
1.2
0.7
1.4
1.2
0.8
16
22
1.9
1.4
0.5
1.9
1.4
0.6
1.8
1.4
0.7
1.8
1.4
0.7
1.7
1.3
0.8
1.7
1.3
0.8
18
25
2.2
1.6
0.5
2.1
1.6
0.6
2.0
1.5
0.7
2.0
1.5
0.7
1.9
1.4
0.8
1.8
1.4
0.8
19
27
2.3
1.6
0.5
2.2
1.6
0.6
2.1
1.6
0.7
2.1
1.5
0.7
2.0
1.5
0.8
1.9
1.5
0.8
22
30
2.5
1.7
0.5
2.4
1.7
0.6
2.3
1.6
0.7
2.3
1.6
0.7
2.2
1.6
0.8
2.1
1.5
0.8
24
32
2.6
1.8
0.5
2.5
1.7
0.6
2.4
1.7
0.7
2.3
1.6
0.8
2.2
1.6
0.8
2.2
1.5
0.8
Indoor Air
Temperature
Outdoor Air Temperature : ˚ CDB
20
25
32
35
40
43
AS-H076QL*0[S07AH SQ0/S07AHP SQ0]
˚CWB ˚CDB
TC
SHC
PI
TC
SHC
PI
TC
SHC
PI
TC
SHC
PI
TC
SHC
PI
TC
SHC
PI
14
20
1.9
1.4
0.4
1.8
1.4
0.5
1.7
1.4
0.6
1.7
1.3
0.7
1.6
1.3
0.7
1.6
1.3
0.7
16
22
2.2
1.6
0.5
2.1
1.6
0.5
2.0
1.5
0.6
2.0
1.5
0.7
1.9
1.5
0.7
1.8
1.5
0.7
18
25
2.4
1.7
0.5
2.4
1.7
0.5
2.3
1.7
0.6
2.2
1.6
0.7
2.1
1.6
0.7
2.1
1.6
0.7
19
27
2.5
1.8
0.5
2.5
1.8
0.6
2.4
1.7
0.7
2.3
1.7
0.7
2.2
1.6
0.7
2.2
1.6
0.8
22
30
2.8
1.9
0.5
2.7
1.9
0.6
2.6
1.8
0.7
2.5
1.8
0.7
2.4
1.7
0.7
2.4
1.7
0.8
24
32
2.9
2.0
0.5
2.8
1.9
0.6
2.7
1.9
0.7
2.6
1.8
0.7
2.5
1.8
0.7
2.4
1.7
0.8
Indoor Air
Temperature
Outdoor Air Temperature : ˚ CDB
20
25
32
35
40
43
AS-C096QL*0[S09AC SQ0/S09ACP SQ0]
˚CWB ˚CDB
TC
SHC
PI
TC
SHC
PI
TC
SHC
PI
TC
SHC
PI
TC
SHC
PI
TC
SHC
PI
14
20
2.2
1.7
0.6
2.2
1.7
0.7
2.1
1.7
0.8
2.0
1.6
0.8
1.9
1.6
0.9
1.9
1.6
0.9
16
22
2.6
2.0
0.6
2.6
1.9
0.7
2.4
1.9
0.8
2.4
1.8
0.8
2.3
1.8
0.9
2.2
1.8
0.9
18
25
2.9
2.1
0.6
2.8
2.1
0.7
2.7
2.0
0.8
2.6
2.0
0.8
2.5
2.0
0.9
2.5
1.9
0.9
19
27
3.0
2.2
0.6
3.0
2.2
0.7
2.8
2.1
0.8
2.8
2.1
0.8
2.7
2.0
0.9
2.6
2.0
0.9
22
30
3.3
2.3
0.6
3.3
2.3
0.7
3.1
2.2
0.8
3.0
2.2
0.9
2.9
2.1
0.9
2.8
2.1
0.9
24
32
3.5
2.4
0.6
3.4
2.3
0.7
3.2
2.3
0.8
3.1
2.2
0.9
3.0
2.1
0.9
3.0
2.1
0.9
Indoor Air
Temperature
Outdoor Air Temperature : ˚ CDB
20
25
32
35
40
43
AS-H096QGA2[G09AH SQ2]
˚CWB ˚CDB
TC
SHC
PI
TC
SHC
PI
TC
SHC
PI
TC
SHC
PI
TC
SHC
PI
TC
SHC
PI
14
20
2.1
1.6
0.6
2.1
1.6
0.7
2.0
1.6
0.9
1.9
1.5
0.9
1.9
1.5
1.0
1.8
1.5
1.0
16
22
2.5
1.8
0.6
2.4
1.8
0.7
2.3
1.8
0.9
2.3
1.7
0.9
2.2
1.7
1.0
2.1
1.7
1.0
18
25
2.8
2.0
0.6
2.7
2.0
0.8
2.6
1.9
0.9
2.5
1.9
0.9
2.4
1.8
1.0
2.4
1.8
1.0
19
27
2.9
2.1
0.6
2.9
2.0
0.8
2.7
2.0
0.9
2.6
1.9
0.9
2.5
1.9
1.0
2.5
1.8
1.0
22
30
3.2
2.2
0.7
3.1
2.2
0.8
3.0
2.1
0.9
2.9
2.0
1.0
2.8
2.0
1.0
2.7
1.9
1.0
24
32
3.3
2.2
0.7
3.2
2.2
0.8
3.1
2.1
0.9
3.0
2.1
1.0
2.9
2.0
1.0
2.8
2.0
1.1
Indoor Air
Temperature
Outdoor Air Temperature : ˚ CDB
20
25
32
35
40
43
■
Symbol
AFR: Air flow rate...........................................................[m3/min]
DB: Dry bulb temperature ......................................................[˚C]
WB: Wet bulb temperature ....................................................[˚C]
TC: Total capacity.................................................................[kW]
SHC: Sensible capacity ........................................................[kW]
PI: Power Input .....................................................................[kW]
(Comp.+ indoor fan motor+outdoor fan motor)
■
Notes :
1. All capacites are net, evaporator fan motor heat is deducted.
2. Indicates nominal capacity.
3. Direct interpolation is permissible. Do not extrapolate
4. Capacities are based on the following conditions:
- Interconnecting Piping Length 7.5m
- Level Difference of Zero.