Service Manual 45
Troubleshooting Guide
Balance Refrigerant of the 3-way Valve
(Gas leakage)
• Procedure
(1) Confirm that both the 2-way and 3-way
valves are set to the back seat.
(2) Connect the charge set to the 3-way
valve’s port.
– Leave the valve on the charge set closed.
– Connect the charge hose to the service
port.
(3) Open the valve (Lo side) on the charge set
and discharge the refrigerant until the
gauge indicates 0 kg/cm
2
G.
– If there is no air in the refrigerant cycle (the
pressure when the air conditioner is not
running is higher than 1 kg/cm
2
G), dis-
charge the refrigerant until the gauge indi-
cates 0.5 to 1 kg/cm
2
G. if this is the case, it
will not be necessary to apply a evacuatin.
– Discharge the refrigerant gradually; if it is
discharged too suddenly, the refrigeration
oil will also be discharged.
Lo
Open
Open
3-Way
valve
3-Way
valve
Gas side
CLOSE
OPEN
Outdoor unit
Liquid side
Indoor unit
Содержание ARTCOOL LA121CNM
Страница 58: ...58 Room Air Conditioner Schematic Diagram Schematic Diagram Electric Control Device Indoor ...
Страница 59: ...Service Manual 59 Schematic Diagram Outdoor 12k ...
Страница 60: ...60 Room Air Conditioner Schematic Diagram Wiring Diagram Indoor Unit Models 12k ...
Страница 61: ...Service Manual 61 Outdoor Unit Models 12k C O Models 12k H P Schematic Diagram ...
Страница 62: ...62 Room Air Conditioner Schematic Diagram Components Location Indoor MAIN P W B ASSEMBLY TOP VIEW BOTTOM VIEW ...
Страница 63: ...Service Manual 63 Outdoor 12k TOP VIEW BOTTOM VIEW Schematic Diagram ...
Страница 71: ...P No MFL31443001 Printed in Korea ...