Date:
Job
Name/Location:
PO
No.:
Architect:
Engr:
GC:
Rep:
For:
File
Approval
Mech:
Resubmit
Other
(Company)
(Project
Manager)
Tag
#:
ARNU093SEL2
Multi
V™
Wall
Mounted
Unit
Btu/h
Indoor
Unit
Controls
Features:
•Auto
changeover
(Heat
Recovery
only)
•Auto
opera on
•Auto
clean
(coil
dry)
•Auto
restart
•Child
lock
•Dual
thermistor
control
•Forced
opera on
•Group
control
•Hot
start
•Self
diagnos cs
•Sleep
mode
•Timer
(on/o
ff
)
•Weekly
schedule
•So
dry
(dehumidi
fi
ca on)
•Auto
direc on/swing
(up/down)
•Manual
Direction
(left/right)
•Fan
speed
control
•Chaos
swing
(random
louver
swing)
•Chaos
wind
(random
fan
speed)
•Jet
cool
(fast
cooling)
Optional
Accessories:
LG
Electronics
USA,
Inc.
1000
Sylvan
Ave,
Englewood
Cliffs,
NJ
07632/www.lg.com/us/
For
continual
product
development,
LG
reserves
the
right
to
change
specifications
without
notice.
Page
1
of
2
VRF
‐
SB
‐
DB
‐
002
‐
US
011H03
Standard
Features:
•Limited
Warranty
with
LG
Cer
fi
ed
Installa on
•Two
Year
Func onal
Parts
Warranty
Unit
Data:
Refrigerant
Type
R410A
Refrigerant
Control
EEV
Net
Unit
Weight
(lbs)
20
Shipping
Weight
(lbs)
25
Fan:
Type
Cross
Flow
Quantity
1
Motor/Drive
Brushless
Digitally
Controlled/Direct
Airflow
Rate
H/M/L
(CFM)
247/230/212
Entering
Mixed
Air:
Heating
Min
(°F
DB)
59
Wireless
Handheld
Remote
Controller
(PQWRHDF0)
7
‐
Day
Programmable
Controller
(PQRCUSA)
Simple
Controller
with
Mode
(PQRCUCS0C)
Simple
Controller
without
Mode
(PQRCFCS0C)
Dry
Contact
Unit
(PQDSB1,
PQDSBC)
Performance:
Cooling
Nominal
Test
Conditions:
Heating
Nominal
Test
Conditions:
Indoor:
80°F
DB/67°F
WB
Outdoor:
95°F
DB
Indoor:
70°F
DB
Outdoor:
47°F
DB/43°F
WB
Heating
Capacity
(Btu/h)
10,900
Electrical:
Power
Supply
(V/Hz/Ø)
208
‐
230/60/1
Rated
Amps
(A)
0.3
Piping:
Refrigerant:
Liquid
Line
(in,
OD)
1/4
Flare
Vapor
Line
(in,
OD)
1/2
Flare
Condensate:
Power
Input¹
(W)
40
Condensate
Line
(in,
OD)
5/8
Total
Cooling
Capacity
(Btu/h)
9,600
9,600
Notes:
Factory
Installed
Pump
No
Cooling
Max²
(°F
WB)
76
Sound
Pressure³
dB(A)
(H/M/L)
39/35/25
Primary
Filter
Washable
Pre
‐
filter
Secondary
Filter
Plasma
1.The
Power
Input
is
rated
at
high
speed.
2.See
Engineering
Manual
for
sensible
and
latent
capaci es.
3.Sound
Pressure
levels
are
tested
in
an
anechoic
chamber
under
ISO
Standard
1996.
4.All
communica on
cable
to
be
minimum
18
AWG,
2
‐
conductor,
stranded,
shielded
and
must
comply
with
applicable
local
and
national
code.
5.Power
wiring
cable
size
must
comply
with
the
applicable
local
and
na onal
code.
6.This
unit
comes
with
a
dry
nitrogen
charge.
7.This
data
is
rated
0
above
sea
level,
with
25
of
refrigerant
line
per
indoor
unit
and
a
0
level
difference
between
outdoor
and
indoor
units.
All
capacities
are
net
with
a
combination
ratio
between
95
–
105%.
8.Must
follow
installa on
instruc ons
in
the
applicable
LG
installa on
manual.