background image

MFL69981502

Rev.00_081618

INSTALLATION MANUAL

AIR

CONDITIONER

Please read this installation manual completely before installing the product.
Installation work must be performed in accordance with the national 
wiring standards by authorized personnel only.
Please retain this installation manual for future reference after reading 
it thoroughly.

 
PACP5A000
Original instructions  

HVAC Controller(ACP 5)

www.lg.com

Copyright © 2018 LG Electronics Inc. All Rights Reserved.

ENGLISH

POR
TUGUÊS

MAL

TI

MA
G

YAR

SLOVENČINA

БЪЛГАРСКИ

SL

OVENŠČINA

SRPSKI

LAT

VIEŠU V

ALO

DA

HR
VA

TSKI

LIETUVIŲ KALBA

SVENSKA

GAEIL

GE

NORSK

МАКЕДОНСКИ

SUOMI

SHQIP

DANSK

ÍSLENSKA

EESTI KEEL 

BOSANSKI

IT

ALIANO

ESP
AÑOL

FRANÇAIS

DEUTSCH

ΕΛΛΗΝΙΚΆ

ČEŠTINA

NEDERL

ANDS

POL

SKI

LIMBA ROMÂNĂ

1,MFL69981502,영영  2018. 8. 17.  영영 1:26  Page 1

Содержание ACP 5

Страница 1: ...anual for future reference after reading it thoroughly PACP5A000 Original instructions HVAC Controller ACP 5 www lg com Copyright 2018 LG Electronics Inc All Rights Reserved ENGLISH PORTUGUÊS MALTI MAGYAR SLOVENČINA БЪЛГАРСКИ SLOVENŠČINA SRPSKI LATVIEŠU VALODA HRVATSKI LIETUVIŲ KALBA SVENSKA GAEILGE NORSK МАКЕДОНСКИ SUOMI SHQIP DANSK ÍSLENSKA EESTI KEEL BOSANSKI ITALIANO ESPAÑOL FRANÇAIS DEUTSCH Ε...

Страница 2: ...er Follow the below precautions properly else it might result in a fire disaster risk of incurring electric shock injuries or product malfunctioning Install the product in an area shielded from rain Follow the below precautions properly else it might result in a fire disaster risk of incurring electric shock injuries or product malfunctioning Do NOT install the product in a humid area Follow the b...

Страница 3: ...sing an unauthorised non standard cord may result in a fire or electric shock Do NOT use a heat device near the power cord Follow the below precautions properly else it might result in a fire disaster risk of incurring electric shock injuries product malfunctioning or damage to property Ensure that water never gets into the product Follow the below precautions properly else it might result in a fi...

Страница 4: ...y water on the product or clean it with a water soaked cloth Follow the below precautions properly else it might result in a fire disaster risk of incurring electric shock injuries product malfunctioning or damage to property Do NOT use the product for the preservation of animals and plants precision instruments art pieces or for other special purposes Follow the below precautions properly else it...

Страница 5: ...ernal components of the product The product may malfunction Check whether the product is in a proper condition after using the product for an extended period of time Deteriorating condition of the product may cause injury to the user Do NOT leave the product near a flower base water bottle or any other liquids It may cause a fire or electric shock If the liquid crystal of the product is broken ple...

Страница 6: ...ences for the environment and human health Your old appli ance may contain reusable parts that could be used to repair other products and other valuable materials that can be recycled to con serve limited resources 3 You can take your appliance either to the shop where you purchased the product or contact your local government waste office for details of your nearest authorised WEEE collection poi...

Страница 7: ... interlocked ACP 5 Components Inside the packaged box of the ACP 5 there are the components as in the following drawing Open the packaged box of the ACP 5 and check if all of the corresponding components are included PACP5A000 ACP 5 Power Cord 250 V 3A Screw SD Card 8 GB Manual Power Supply Adaptor Input 100 240 V 50 60 Hz 1 2 A Output DC 12 V 3 33 A 40 W MAX NOTE Components or options may differ ...

Страница 8: ...nal input output sig nals DI 2 DO 2 Optional input output and RS 485 communication port Connection port to connect to external input output signals and RS 485 communication port for external expansion 8 DI s 2 DO s 2 RS 485 communication ports RS 485 communication port RS 485 communication ports to connect to air conditioner and ERV equipment 4 in total Mini USB port USB to Serial port for softwar...

Страница 9: ...x 2 3 A Communication port Ethernet 10 100 BASE T USB USB Host SW upgrade data backup Mini USB Device Debug RS 485 communication ports 6EA SD card slot RS 485 communication logging External input output ports DI 10 EA DO 4 EA LED 27EA power status communication status LCD 20 4 Character LCD network environment setting and information display Protection class IP20 1 MFL69981502 영영 2018 8 14 영영 2 35...

Страница 10: ...ACP 5 and set network and other settings STEP 6 Set ACP 5 network address Set the network address to be able to access the ACP 5 through internet STEP 7 Set ACP 5 functions Set language peak demand etc STEP 8 Set web GUI access environment Set the access environment in web GUI which is the operation program of the ACP 5 STEP 9 Input indoor unit and ventilator information Set the access environment...

Страница 11: ...different depending on the quantity of connected I O modules Please refer to following information related to product connection quantity Devices Indoor units ERV DI DOs DOKITs Heatings AHUs RS 485 communication cable connection There is a polarity in RS 485 communication cable connection so be careful not to reverse the connection of the two cables Do not let the length of RS 485 communica tion c...

Страница 12: ...ON OFF Heating AHU Indoor devices 1 Configuration Address 01 Configuration Address 11 Configuration Address 21 Configuration Address 31 Configuration Address 41 Configuration Address 02 Configuration Address 03 Indoor devices 2 Indoor devices 3 NOTE Assigning indoor and outdoor unit number If the outdoor unit product is Multi V it is recommended to assign the address by setting the first digit of ...

Страница 13: ...ide the space to install the ACP 5 Before installing the ACP 5 check if it is the adequate place to connect the ACP 5 with the power RS 485 and LAN cable Install DIN RAIL Hook the top part of the ACP 5 on DIN RAIL Push the main body of the ACP 5 until you hear the sound of installation Pull the ACP 5 to check if it is fixed PACP5A000 Power LAN cable RS 485 cable PACP5A000 Hooking on DIN RAIL Fixin...

Страница 14: ...able that was connected to PI485 shall be connected to CH port RS 485 port of the ACP 5 Plug the connector connecting RS 485 cable into one of CH1 CH4 ports There are 1 6 CH ports and it must be plugged into one of 1 4 ports for use For AHU plug the connector connecting RS 485 cable into CH5 ports For chiller plug the connector connecting RS 485 cable into CH6 ports with chiller option S W applied...

Страница 15: ...way address Net mask Before configuring the ACP 5 envi ronment The network environment of the ACP 5 can be set by the LCD and the buttons at the front side of the ACP 5 The current ACP 5 information and the menu are displayed on the LCD and the menu can be changed and selected by pressing and button and Up Down Left Right buttons A B A B A B A B A B A B PACP5A000 PACP5A000 Connecting ACP 5 and PC S...

Страница 16: ...following figure In Function menu ACP 5 software service function is supported ACP 5 SW v e r 1 0 0 0 I P 1 9 2 1 6 8 0 0 1 1 0 0 GW 1 9 2 1 6 8 0 0 1 0 0 1 Wa i t f o r b o o t i n g Network Info IP 000 000 000 000 GW 000 000 000 000 MS 000 000 000 000 MC 000000 00 00 00 DHCP NO Function S W update DB back up DB recover Data Logging Language Net Test HTTPS Port Reset T E S 1 2 Network Info Functi...

Страница 17: ... Run cmd ipconfig without the installation of another program the central control program ACP 5 Web server is executed automatically Login You can login as follows 1 Run ACP 5 2 Input ID and password in log in window and touch Log in button Log in for first time access In case of initially accessing set password for the manager account ID admin 1 Run ACP 5 2 Input password of manager account to use...

Страница 18: ... In ACP 5 log in screen input ID and password and touch Log in button 2 Press Help at the top right side of ACP 5 screen The user manual is displayed Do NOT disclose account related info to unauthorised personnel In case you have forgotten your password contact the installer CAUTION NOTE To maintain confidentiality change the password once in every 90 days as prompted by the pop up window 1 MFL699...

Страница 19: ...ve set the time schedule may be disabled I would like to change the name of the indoor unit Log in as superuser System Settings After select the device you want to change modify the name of or the device Apply Complete group settings Removal of waste batteries and accumulators Product with embedded battery ONLY In case this product contains a battery incorporated within the product which cannot be...

Страница 20: ...20 ENGLISH 1 MFL69981502 영영 2018 8 14 영영 2 36 Page 20 ...

Страница 21: ...uropean Shared Service Center B V Krijgsman 1 1186 DM Amstelveen The Netherlands Manufacturer LG Electronics Inc Changwon 2nd factory 84 Wanam ro Seongsan gu Changwon si Gyeongsangnam do KOREA 1 MFL69981502 영영 2018 8 14 영영 2 35 Page 500 ...

Отзывы: