background image

www.lg.com

P/NO : MFL67888801

OWNER’S MANUAL

AIR CONDITIONER 

Please read this manual carefully before operating
your set and retain it for future reference.

TYPE : 4-Way Ceiling Cassette

MODELS
Indoor Unit
AMNC12GTRA2
AMNC18GTQA2
AMNC24GTPA2

A7UQ40GFA0
A8UQ48GFA0
A8UQ54GFA0

Outdoor Unit
A2UQ18GFA0
A3UQ26GFA0
A4UQ30GFA0
A5UQ36GFA0
A5UQ48GFA0

ENGLISH

ESP

AÑOL

POR

TUGUESE

Содержание A2UQ18GFA0

Страница 1: ...l carefully before operating your set and retain it for future reference TYPE 4 Way Ceiling Cassette MODELS Indoor Unit AMNC12GTRA2 AMNC18GTQA2 AMNC24GTPA2 A7UQ40GFA0 A8UQ48GFA0 A8UQ54GFA0 Outdoor Unit A2UQ18GFA0 A3UQ26GFA0 A4UQ30GFA0 A5UQ36GFA0 A5UQ48GFA0 ENGLISH ESPAÑOL PORTUGUESE ...

Страница 2: ...irection of the air flow vertically or horizontally to circulate indoor air Speed up the fan to cool or warm indoor air quickly in a short period of time Open windows regularly for ventilation as the indoor air quality may deteriorate if the air con ditioner is used for many hours Clean the air filter once every 2 weeks Dust and impurities collected in the air filter may block the air flow or weak...

Страница 3: ... or repair the product There is risk of fire or electric shock Always ground the product There is risk of fire or electric shock Install the panel and the cover of control box securely There is risk of fire or electric shock Always install a dedicated circuit and breaker Improper wiring or installation may cause fire or electric shock Use the correctly rated breaker or fuse There is risk of fire o...

Страница 4: ...nds or small or smoke comes from product Turn the breaker off or disconnect the power supply cable There is risk of electric shock or fire Stop operation and close the window in storm or hurricane If possible remove the product from the window before the hurricane arrives There is risk of property damage failure of product or electric shock Do not open the inlet grill of the product during operati...

Страница 5: ...mage to the plastic parts of the product Do not touch the metal parts of the product when removing the air filter They are very sharp There is risk of personal injury Do not step on or put anyting on the product outdoor units There is risk of personal injury and fail ure of product Always insert the filter securely Clean the filter every two weeks or more often if necessary A dirty filter reduces ...

Страница 6: ...ode Standard Operation 11 Cooling Mode Power Cooling 11 Auto Operation Mode 12 Dehumidification Mode 12 Fan Mode 12 Temperature Setting Room Tempera ture checking 13 Airflow Setting 14 Plasma Purification Optional 14 Celsius Fahrenheit Switching 15 Individual vane angle control Optional 16 Timer 17 MAINTENANCE AND SERVICE 17 Indoor Unit 18 Purifying filter Optional 19 Operation Tips 19 When the ai...

Страница 7: ...ing precision de vices food pets plants and art objects Such usage could damage the items Cleaning and maintenance Do not touch the metal parts of the unit when removing the filter Injuries can occur when han dling sharp metal edges Do not use water to clean inside the air conditioner Exposure to water can destroy the insula tion leading to possible electric shock When cleaning the unit first make...

Страница 8: ...al from remote control signal receiving sound two short beeps and one long beep 5 Filter sign Lights up after 2400 hours from the time of first operation 6 On Off Lights up during system operation Operation Indication Lamps 1 2 3 4 5 6 Name and function of parts 1 Indoor unit 2 Outdoor unit 3 Remote controller 4 Inlet air 5 Discharge air 6 Refrigerant piping connection electric wire 7 Drain pipe 8...

Страница 9: ...election button Selects the operation mode Cooling Operation Auto Operation Dehumidifying Operation Heating Operation Fan Operation Air flow direction selection button Adjusts the air flow direction vertically or horizontally Subfunctions button Sets additional functions including plasma purification dehumidifying electric heating and the child lock Function setting button Enters custom setting mo...

Страница 10: ... CHECKING Button Used to check the room tempera ture 15 OFF TIMER Button Used to set the time of stopping op eration 16 TIMER SETTING Up Down LIGHT Button Used to set the timer Used to adjust the brightness if it is not time adjust mode 17 RESET Button Used to reset the remote controller 1 8 9 10 11 12 13 14 15 16 17 2 3 4 5 6 7 Wireless Remote Controller This air conditioner is equipped with wire...

Страница 11: ...ing Mode press the Jet Cool button or the fan button or the room temperature setting button again and the unit will operate in high fan speed in cooling mode Auto Operation Mode 1 Press the ON OFF button The unit will respond with beep sound 2 Press MODE button to select Auto Opera tion Mode 3 Set the desired temperature For Cooling Model The temperature and fan speed are automati cally set by the...

Страница 12: ...tion the air volume is automatically set according to the algorithm respond ing to the current room temp and makes the room condition healthy and comfortable even in the high humidity season Natural Wind by the chaos Logic For more fresh feeling than other fan speed press the Indoor Fan Speed Se lector and set to chaos mode In this mode the wind blows like natural breeze by automatically changing ...

Страница 13: ...l swing left and right Press the Horizontal Airflow Direction Control Button again to set the horizontal louver at the desired air flow direction Up Down and Left Right Airflow function isn t shown on display of remote controller Airflow Setting NOTE If you press the UP DOWN AIRFLOW button the horizontal airflow direction is changed au tomatically based on the Auto Swing algorithm to distribute th...

Страница 14: ...ma filter is a technology developed by LG to get rid of microscopic contaminants in the intake air generating a plasma of high charge electrons This plasma kills and de stroys the contaminants completely to pro vide clean and hygienic air This function can be used in any operation mode and any fan speed can be used while plasma filter is functioning Press the C F SWITCH button to change from Celsi...

Страница 15: ...re sponding vane angle and set values are displayed When up direction button is pressed the display window appears as of the figure in the right and the angle can be set to 1 6 Multi V Console products can be con trolled by up key in the up down control 3 Press SET CLEAR button to reserve or cancel the individual vane angle control function There may be differences between wireless remote controll...

Страница 16: ...s the SET CLEAR button To cancel the Timer Setting If you wish to cancel all timer setting press the CLEAR ALL button If you wish to cancel each timer setting press the SET CLEAR button to turn timer sleep or on or off as you want And then press the SET CLEAR button aiming the remote controller at the signal receptor The timer lamp on the air conditioner and the display will go off Timer NOTE Chec...

Страница 17: ...old of the tab and pull slightly forward to remove the filter Clean dirt from the air filter using a vacuum cleaner or washing with water If dirt is conspicuous wash with a neutral detergent in lukewarm water If hot water 50 C or more is used it may be deformed After washing with water dry well in the shade Do not expose the air filter to direct sunlight or heat from a fire when drying it Install ...

Страница 18: ...pull slightly for ward to remove the PLASMA filter Dip the PLASMA filter into the water mixed with neutral detergent for 20 30 minutes Dry the PLASMA filter in the shade for a day Especially the humidity must be removed perfectly on this parts Note the cuts of electric discharge lines Re install the PLASMA filter to the original position Recomended use period About 2 years Open front panel and rem...

Страница 19: ...the air conditioner is not going When air conditioner is not going to be used for a long time Operate the air conditioner at the following settings for 2 to 3 hours Type of operation Fan operation mode Refer to page 12 This will dry out the internal mechanisms Turn off the breaker Remove the batteries from the Remote Con troller Helpful information The air filters and your electiric bill If the ai...

Страница 20: ...restart This is the protector of the mechanism Wait about three minutes and opera tion will begin Does not cool or heat effectively Is the air filter dirty See air filter cleaning instructions The room may have been very hot when the room air condi tioner was first turned on Allow time for it to cool down Has the temperature been set incorrectly Are the indoor unit s air inlet or outlet vents obst...

Страница 21: ...60 Hz 0 43 A AMNC24GTPA2 220 V 50 60 Hz 0 60 A A2UQ18GFA0 220 V 50 60 Hz 6 6 A A3UQ26GFA0 220 V 50 60 Hz 9 4 A A4UQ30GFA0 220 V 50 60 Hz 9 8 A A5UQ36GFA0 220 V 50 60 Hz 12 5 A A5UQ48GFA0 220 V 50 60 Hz 17 0 A A7UQ40GFA0 220 V 50 60 Hz 11 4 A A8UQ48GFA0 220 V 50 60 Hz 14 5 A A8UQ54GFA0 220 V 50 60 Hz 19 2 A ...

Страница 22: ...22 ENGLISH ...

Страница 23: ...FA0 A4UQ30GFA0 A5UQ36GFA0 A5UQ48GFA0 A7UQ40GFA0 A8UQ48GFA0 A8UQ54GFA0 LG Electronics México S A de C V Sor Juana Inés de la Cruz No 555 Col San Lorenzo Industrial Tlalnepantla de Baz Estado de México C P 54033 TEL 5321 1919 Teléfono sin costo 01 800 347 1919 Página web http www lg com mx ...

Отзывы: