98 Multi type Air Conditioner
Operation
Function of Outdoor Unit
Outdoor Unit
Two Comp algorithm
Operating Frequency
LEV Control
Out door Fan Control
• Inverter Frequency varies considering condition such as room temp,outdoor temp, operating room
number,Temp gap between room temp and set temp and so on.
• LEV pulse is modulated to keep constant superheat or subcooling.
• Outdoor fan operates at High/Low or Off to respond to the load condition.
R/Valve Control
• Convert R/Valve to change cooling to heating, heating to cooling.
Comp Pre-Heat Logic
• Checking outdoor temp, D-Pipe temp,Heat Sink Temp, operate compressor at low frequency upto
5min to preheat oil.
Defrost Function
• After 35 min heating operation, check the defrost condition and if outdoor pipe temp is below -6
°
C and
released from deice operation in case outdoor pipe temp is over 15
°
C or 7 min cooing mode.
• To deice outdoor heat exchanger in low temp condtion, convert operating mode from heating to
cooling, in this case, indoor and outdoor fan is off.
Oil Return System
• In heating operation, every 3 hours, changes from heating to cooling for 5 min to return the oil in piping
to compressor.
IPM Over Heat Protection
• To protect IPM overheat, down comp Hz.
Comp Overload Protection
• To protect comp from being overload, down comp Hz.
Low Pressure Protection
• If cylce pressure is low (around 0.3kgf/cm2), turn off comp and outdoor fan.
• Inverter Comp is first priority and then Constant Comp is turning on responding to load condtion.
Содержание A2UQ166FA0
Страница 135: ...Service Manual 135 Schematic Diagram 2 Art Cool Type ...
Страница 136: ...136 Multi type Air Conditioner Schematic Diagram 3 Art Cool Deluxe Type ...
Страница 147: ...Service Manual 147 Schematic Diagram 1 Indoor Unit MAIN P C B ASM 1 Split Type Components Locations DC part AC part ...
Страница 148: ...148 Multi type Air Conditioner Schematic Diagram 2 Art Cool Type TOP VIEW BOTTOM VIEW ...
Страница 150: ...150 Multi type Air Conditioner Schematic Diagram 4 Duct Type High static BH BG chassis Built in type BP chassis ...
Страница 151: ...Service Manual 151 Schematic Diagram Low static BT BT1 chassis ...
Страница 152: ...152 Multi type Air Conditioner Schematic Diagram 5 Casset Type 1 way TC chasis ...
Страница 153: ...Service Manual 153 Schematic Diagram 4 way TE TF TD chasis 58 B ...
Страница 155: ...Service Manual 155 Schematic Diagram VB chassis ...
Страница 158: ...158 Multi type Air Conditioner Schematic Diagram 3 Outdoor Unit 1 Component side ...
Страница 159: ...Service Manual 159 Schematic Diagram 2 Solder side ...
Страница 160: ...160 Multi type Air Conditioner Schematic Diagram 3 Central control PCB 2 Bottom View 1 Top View ...
Страница 161: ...Service Manual 161 4 SUB P W B ASSEMBLY 1 Art Cool Type TOP VIEW BOTTOM VIEW Schematic Diagram ...
Страница 238: ...P No 3828A22009C October 2006 Printed in Korea ...