Standard Repair Process Detail Technical Manual
A18
Standard Repair Process Detail Technical Manual
SET Model
Power P/N, Name
70UM
69/71/
73
EAY65248601, LGP70T-19U1
MS Level
Range [V]
LED On/Off
MS (0V)
0 ~ 0.25
Off
MS (2V)
1.75 ~ 2.25
On (Home mode)
MS (3V)
2.75 ~ 3.25
On (Store Mode)
Power Check Sequence
1. AC input Check : SK100 (100~240Vac)
2. PWR-ON Check :
- SET On : above 3V
- SET St-by : 0V
3. 13.2V DC Check :
- SET On : 13.2V
- SET St-by : 7.8V
4. MS Level Check : MS
5. LED voltage Check : P801, Pin 1-7
※
Home mode : General Customer
Store mode : use Store
Picture Condition : VIVID (Back light 100)
Min
Max
273.6V
334.4V
all condition meets, Power Board OK.
SK100 (AC input)
P801
P201
Established
date
Revised
date
A18
Error
symptom
Content
Check power input voltage and ST-BY 7.8V
B. Power error _No power
Copyright © 2019 LG Electronics Inc. All rights reserved.
Only for training and service purposes.
Содержание 75UM6970PUB
Страница 95: ......