Checking order
1. Check IR cable condition between IR & Main board.( Check picture number
①
and
②
)
2. Check the standby 3.5V on the terminal 6 pin. (
③
)
3. AS checking the Pre-Amp(IR LED light), the power is in ON condition, an Analog Tester
needle should move slowly, otherwise, it’s defective.
Standard Repair Process Detail Technical Manual
Remote control operation checking method
D. Function error
A22
Established
date
Revised
date
Error
symptom
Content
A22
Checking order to check remote control
① IR & EYE Sensor
Pin
Pin name
1
VCC
2
USB_DM
3
USB_DP
4
GND
5
WOL/WIFI_ON
6
VCC
7
WIFI_Suspend/Resume
8
GND
9
Combo_Reset
10
BT_WAKEUP_HOST
11
GND
12
VCC
13
14
15
16
EYE_SDA
17
EYE_SCL
18
GND
19
IR
20
LED_R
21
GND
22
VCC
23
KEY2
24
MIC_DATA
25
MIC_CLK
②
③
* Depending on models
< Below 75inch_ NANO7*,UP8*,UP77 >
< Below 75inch_UP75/71 >
Copyright © 2021 LG Electronics Inc. All rights reserved.
Only for training and service purposes.