- 14 -
LGE Internal Use Only
Copyright LG Electronics. Inc. All right reserved.
Only for training and service purposes
5.7.2. Preset CH write condition
1) AC on time on only one after assembled automatically
2) In case of PAL model, CH recover on SVC OSD manually
In case of NTSC model, default channel : -> After In-Stop /
Facotry reset
TV : 2,3,4,5,6,7,8,9,10,11,12,13,14,30,51,55,63 CATV :
15,16,17,55,95
5.7.3. Preset CH erase condition
1) In-Stop key
5.8. Internal press test
5.9. Motion Remote controller Inspection
5.9.1. Equipment : Motion remote controller for
test, IR-KEY-CODE remote controller for
test Check battery before test.
(Recommend : Change battery for every
Lot.)
5.9.2. Process
1) Push “Mute” or “ START” key for pairing between TV-set
and motion remote controller.
2) Push “OK” or “Enter” key, you can see the Cursor on
screen.
3) Push “Vol+” or “STOP” key, Disconnect Pairing.
5.10. 3D Function test
5.10.1. Equipment : Pattern Generator MSPG-
3233, HDMI mode 37, pattern No. 81
5.9.2. Process
1) Connect HDMI (HDMI mode 371, Pattern No. 81)
2) Insert 3D Mode, Select side by side mode.
3) Without 3D-glasses, Like below figure.
4) With 3D left-glass, Like below figure. (Center is RED)
5) With 3Dright-glass, Like below figure.(Center is Blue)
No Item Vallue
Unit Remark
1. Dielectric Voltage(AC<->FG)
1.5
kV
At 100mA for 1sec(Line)
1.5
At 100mA for 1min(OQC)
2. Dielectric Voltage(Without FG)
3
kV
At 100mA for 1sec(Line)
3
At 100mA for 1min(OQC)