ipLDK-60
Issue 2.0
Admin Programming Manual
July, 2010
3
At this point, the DKT is in the Program mode and can access the
various PGMs and parameters. Specific instructions for each
parameter are provided in the Admin Procedures given in section 3.
To access a specific PGM while in the Program mode,
1. Press
the
[TRANS/PGM]
button
2. Dial the 3-digit PGM code.
2.2.2
Navigation and Buttons
While in the Program mode, the [Volume Up/Down] can be used for
navigation through the PGM sections. Other buttons on the DKT also
provide special functions during Admin Programming. The BACK
softkey or [CONF] button, if assigned, move back one-step in the
process. The DELETE softkey or the [SPEED] button deletes the
current entry. The SAVE softkey or the
[Hold/Save]
button store an
entry to the system database. A value must be saved with the SAVE
softkey or
[Hold/Save]
button prior to moving to another parameter.
2.2.3
Entering and Saving Data
In most cases, after selecting a PGM, a specific parameter is selected
using a Flexible button and a value entered with the dial pad. When a
value is saved, the system will verify the value is in range and does not
conflict with other parameter settings. If the data value is valid,
confirmation tone is received. If the value is not valid, error tone is
received and a valid value can be entered without further action.
In some cases, after selecting a PGM, the Flexible buttons are used to
toggle a parameter value. In this case, the value is not checked since
the Flexible button only toggles the value ‘On’ or ‘Off’.
In certain PGMs e.g., a Station, CO line PGM group, the desired
station or CO line range is required. Once the parameter is selected,
the LCD will indicate the parameter value for the first station or CO line
in the range. Entering a single station or CO line number for both the
upper and lower end of the range will change the parameter for the
station or CO line number entered.
2.2.4
Resetting the System
When certain parameter values are changed, the system must be
reset to reorganize memory. Parameters that require a reset after
being changed include:
PGM 100 - Location,
PGM 101 – Board Assignment
PGM 103 – Logical Slot Assignment
PGM 108 – IP Settings
PGM 380 – VOIB Slot Assignment, RSG/IP Phone
PGM 381 – RSG/IP Phone Ports Assignment
Содержание ipldk-60
Страница 1: ...Feature Description Operation Manual ...
Страница 268: ......
Страница 269: ...Admin Programming Manual ...
Страница 388: ...ipLDK 60 Issue 2 0 Admin Programming Manual July 2010 113 Blank 1 2 3 ...
Страница 430: ...ipLDK 60 Issue 2 0 Admin Programming Manual July 2010 155 PGM 223 Flex Btn Description Default Values Initialize ...
Страница 512: ......