![LG Chem RESU Series Скачать руководство пользователя страница 11](http://html.mh-extra.com/html/lg-chem/resu-series/resu-series_installation-manual_1905880011.webp)
Product Introduction
Performance
RESU3.3
RESU6.5
RESU10
Nominal voltage
51.8 V
51.8 V
51.8 V
Operating voltage
42 to 58.8 V
42 to 58.8 V
42 to 58.8 V
Nominal capacity
63 A·h
126 A·h
189 A·h
Nominal energy
3.3 kW·h
6.5 kW·h
9.8 kW·h
Standard power
1.1 kW
2.2 kW
3.3 kW
Maximum power
3 kW
4.2 kW
5 kW
Peak power for 3 seconds
3.3 kW
4.6 kW
7 kW
Maximum current
71.4 A at 42 V
100 A at 42 V
119 A at 42 V
Charging cable requirements
Conductor cross-sectional area
33 to 50 mm
2
Cable outer diameter
14 to 21 mm
Cable lug hole size
M8
Cable lug width
21 mm
Maximum cable length
5 m per cable
Environmental requirements
Available operating temperature
−10 to 45 °C (14 to 113 °F)
Optimal operating temperature
15 to 30 °C (59 to 86 °F)
Storage temperature
−30 to 60 °C (−22 to 140 °F)
Humidity
5 to 95% (non-condensing)
Altitude
Below 2000 m
2.2
Features
The RESU
®
battery pack has the following features:
Photovoltaic system
: This battery pack is designed for photovoltaic system
compatibility.
Battery management system (BMS)
: The battery pack’s built-in BMS moni-
tors its operation and prevents the battery from operating outside design
11