Troubleshooting

Check the indicators on the front of the battery pack to determine in what state

the battery pack is.

Status

Charge/Discharge

Red → Green

a

Off

Successfully initialized

Red → Red

Off

Initialization failed

b

Green

Green

Discharging in normal state

Green

Red

Charging in normal state

Green

Off

Waiting in normal state

Green/Orange

Green

Discharging in warning state

Green/Orange

Red

Charging in warning state

Green/Orange

Off

Waiting in warning state

Off

Off

Circuit breaker tripped

b

a

This should change in 7 seconds.

b

Contact your distributor in this case.

A warning state is triggered when a condition, such as voltage or temperature,

is beyond its design limitations.

The battery pack’s BMS periodically reports its operational state to the inverter.

There are two abnormal states:

Warning

: When the battery pack is likely to become faulty, it goes into warn-

ing state. When a warning is reported, the inverter shows the warning

message on its display but takes no action about it.

Fault

: When the battery pack falls outside prescribed limits, it goes into fault

state. When a fault is reported, the inverter immediately stops its opera-
tion and shows the fault message on the display.

The possible warning or fault messages are as follows:

• Battery Over Voltage
• Battery Under Voltage
• Battery Over Temperature

• Battery Under Temperature
• Battery Discharge Over Current

• Battery Charge Over Current

9

Содержание RESU 6.4 EX

Страница 1: ...Residential Energy Storage Unit 6 4 EX Battery Pack For Photovoltaic Systems User Guide April 2015 Edition 1 ...

Страница 2: ...NOTE The information included in this document is accurate at the time of pub lication However this product is subject to change without prior notice ...

Страница 3: ... 5 2 Safety 7 2 1 General Precautions for the Battery Pack 7 2 2 Warning Labels 8 3 Troubleshooting 9 4 Emergency Situations 11 4 1 Leaking Batteries 11 4 2 Fire 11 4 3 Wet Batteries 12 4 4 Damaged Batteries 12 5 Warranty 13 5 1 Warranty Coverage 13 5 2 Limitation of Liability 13 3 ...

Страница 4: ...dding expan sion battery packs 1 2 LED Indicators Stat us Cha rge Disc harg e RES U 6 4 R Status Charge Discharge RESU 6 4 EX R The LED indicators on the front of the battery pack show its operational state as follows Standby When the battery pack is ready for operation the Status indi cator is lit in red Normal operation When the battery pack is in normal operation the Status indicator is lit in ...

Страница 5: ...g or fault state the Sta tus indicator alternately flashes in green and orange See Troubleshoot ing on page 9 1 3 Specifications Dimensions and weight Length 406 mm Width 165 mm Height 664 mm Weight 60 kg Status Ch arge Discha rge RE SU 6 4 R 664 165 406 5 ...

Страница 6: ...current constant voltage charging mode bin constant current discharging mode Cable requirements Power cable from inverter 4 AWG 21 mm2 or thicker UL 1283 Cable lug M8 Environmental requirements Available operating temperature 0 C to 40 C Optimal operating temperature 15 C to 30 C Operating relative humidity 25 to 95 Storage temperature 30 C to 50 C Storage relative humidity 25 to 95 Communication ...

Страница 7: ...es in excess of 50 C Do not place the battery pack near a heat source such as a fireplace Do not expose the battery pack to direct sunlight Do not allow the battery connectors to touch conductive objects such as wires Risks of electric shock Do not disassemble the battery pack Do not touch the battery pack with wet hands Do not expose the battery pack to moisture or liquids Keep the battery pack a...

Страница 8: ...injury Use assistance when moving or lifting ㆍKeep out of reach of children or animals ㆍDo not sit or put heavy things on this Battery cover It can cause deflection or fracture Abklemmung YerlegenoderReparaturstrikt verboten Vermeidungvonn Verletyungen elektrischenSchocks oderBranden Service Arbeitensindnurvonautorisierten lngenieuren gestattet Eigenmachtiges Laden oder Entladen verboten Gefahr vo...

Страница 9: ...when a condition such as voltage or temperature is beyond its design limitations The battery pack s BMS periodically reports its operational state to the inverter There are two abnormal states Warning When the battery pack is likely to become faulty it goes into warn ing state When a warning is reported the inverter shows the warning message on its display but takes no action about it Fault When t...

Страница 10: ...l con dition NOTE For a serious fault if no proper corrective actions are taken by the inverter the battery pack s circuit breaker automatically trips to protect itself For example if the Status indicator stays red for more than 5 minutes the cir cuit breaker trips Use the monitoring software on the inverter to identify what caused the fault 10 ...

Страница 11: ...s with flowing water for 15 minutes and seek medical attention Contact with skin Wash the affected area thoroughly with soap and water and seek medical attention Ingestion Induce vomiting and seek medical attention 4 2 Fire In case of fires make sure that the following equipment is available near the battery pack SCBA self contained breathing apparatus and protective gear in compli ance with the D...

Страница 12: ...Damaged batteries are dangerous and must be handled with the utmost care They are not fit for use and may pose a danger to people or property If the battery pack seems to be damaged pack it in its original container and then return it to LG Chem or an authorized dealer NOTE Damaged batteries may leak electrolyte or produce flammable gas If such a damage occurs immediately contact LG Chem at 82 43 ...

Страница 13: ...ge or assume any liability for direct or indirect damages or defects that result from the following causes Transportation or storage Incorrect installation Operating the product in an inappropriate environment Incorrect or inappropriate operation Insufficient ventilation Failure to adhere to safety warnings or instructions Repairs or modifications performed by unauthorized personnel Rectifier fail...

Страница 14: ...Keep this manual for later use LG Chem LG Twin Tower 128 Yeoui daero Yeongdeungpo gu Seoul 150 721 Korea ...

Отзывы: