Summary
Specifications
Product size
Where should install the alarm
Where should not install the alarm
Operation
LX-GSV8-M
Gas Alarm
R
European plug
British plug
72.00mm
European plug
British plug
59.00mm
69.00mm
121.00mm
Reference standard
: EN50194:2000
LX - GSV8 - M for combustible gas alarm (which is a
combustible gas concentration according to customer
requirements for automatic learning save the data, so
as to achieve to the concentration of combustible gas
deviation smaller), adopted the international advanced
gas sensitive sensor technology, selection of
cost-effective microprocessor as control core, (using
the I2C BUS - storage device, follow two wire protocol,
its interface is, small volume, no lose when power
supply drop data etc.) is a kind of comfortable family
family use small gas safety product, used for
continuous detection of indoor concentrations of gas
leakage, When the concentration of leakage reaches
the set value, the detector will give an audible and
visual alarm. When the concentration of indoor gas is
lower than the set alarm value, the detector will
automatically return to the normal working state to
avoid poisoning, explosion, fire and other casualties
and property losses caused by combustible gas
leakage.
Power source: 100-240VAC
Power frequency: 50/60Hz
Rated load: <1.5W
Detect gas: LPG ,natural gas, town gas
Alarm concentration: 2%LEL- 8%LEL
Alarm volume: ≥85dB(3m)
Working environment: -20°C~+40°C
Working humidity: <85%RH
1
.
For the natural gas and town gas detection:
• It should be installed in the room where a gas escape
is most likely to occur, this may be the kitchen because
of the presence of a gas cooker and other gas
appliances.
• It should be installed above the level of a possible gas
escape and near the ceiling(typically 0.3m from the
ceiling), in place where air movements are not
impeded by furniture and furnishings.
2
.
For LPG detection:
• It should be installed in the room where the most
frequently used appliance is accommodated and
where an escape is most likely to occur. In most
domestic premises, this room may be the kitchen
because of the presence of a gas cooker and possibly
other gas appliances.
• It should be mounted as slow as possible(typically
0.1m above the floor) and in place where air
movements are not impeded by furniture .
• Note:When the product first use,need electricity for 8
hours before entering normal working state.
• In an enclosed space(e.g in a cupboard or behind a
curtain)
• Directly above a sink;
• Next to a door or window;
• Next to an extractor fan;
• In an area where the temperature may drop below
-20°C or exceed 40°C;
• where dirt and dust may block the sensor;
• In a damp or humid location.
Power connected, the power indicator (green) is
constantly on, and it alarms with beep sound (alarm
indicator flashes twice). The digital tube displays “-”
and about 5 minutes displays concentration, then it
starts the alarm detection mode.
Use pump to supply the alcohol volatile gas
through the tube to the GS alarm, ensure that the
tube is right to gas sensor.
•
When digital tube says the concentration is
0,1,2 , the status indicator is off.
•
When digital tube says the concentration is