Operation

LX-GSV8-M

Gas Alarm

 R

European plug

British plug

72.00mm

European plug

British plug

59.00mm

69.00mm

121.00mm

Reference standard

: EN50194:2000

LX - GSV8 - M for combustible gas alarm (which is a 

combustible gas concentration according to customer 

requirements for automatic learning save the data, so 

as to achieve to the concentration of combustible gas 

deviation smaller), adopted the international advanced 

gas sensitive sensor technology, selection of 

cost-effective microprocessor as control core, (using 

the I2C BUS - storage device, follow two wire protocol, 

its interface is, small volume, no lose when power 

supply drop data etc.) is a kind of comfortable family 

family use small gas safety product, used for 

continuous detection of indoor concentrations of gas 

leakage, When the concentration of leakage reaches 

the set value, the detector will give an audible and 

visual alarm. When the concentration of indoor gas is 

lower than the set alarm value, the detector will 

automatically return to the normal working state to 

avoid poisoning, explosion, fire and other casualties 

and property losses caused by combustible gas 

leakage.

Power source: 100-240VAC

Power frequency: 50/60Hz

Rated load: <1.5W

Detect gas: LPG ,natural gas, town gas

Alarm concentration: 2%LEL- 8%LEL

Alarm volume: ≥85dB(3m)

Working environment: -20°C~+40°C

Working humidity: <85%RH

1

For the natural gas and town gas detection:

• It should be installed in the room where a gas escape 

is most likely to occur, this may be the kitchen because 

of the presence of a gas cooker and other gas 

appliances.

• It should be installed above the level of a possible gas 

escape  and  near  the  ceiling(typically  0.3m  from  the 

ceiling), in place where air movements are not 

impeded by furniture and furnishings.

2

For LPG detection:

•  It  should  be  installed  in  the  room  where  the  most 

frequently used appliance is accommodated and 

where an escape is most likely to occur. In most 

domestic premises, this room may be the kitchen 

because of the presence of a gas cooker and possibly 

other gas appliances.

•  It  should  be  mounted  as  slow  as  possible(typically 

0.1m above the floor) and in place where air 

movements are not impeded by furniture .

• Note:When the product first use,need electricity for 8 

hours before entering normal working state.

• In an enclosed space(e.g in a cupboard or behind a 

curtain)

• Directly above a sink;

• Next to a door or window;

• Next to an extractor fan;

•  In  an  area  where  the  temperature  may  drop  below 

-20°C or exceed 40°C;

• where dirt and dust may block the sensor;

• In a damp or humid location.

  

Power connected, the power indicator (green) is 

constantly on, and it alarms with beep sound (alarm 

indicator flashes twice). The digital tube displays “-” 

and about 5 minutes displays concentration, then it 

starts the alarm detection mode.

  

Use pump to supply the alcohol volatile gas 

through the tube to the GS alarm, ensure that the 

tube is right to gas sensor. 

  

• 

When digital tube says the concentration is 

0,1,2 , the status indicator is off.

  

• 

When digital tube says the concentration is 