PUFP-CT-PB SERIES INSTALLATION GUIDE 

 

It is highly recommended that in addition to reading the below installation instructions, 
that the installation video is watched at 

http://y2u.be/S9x2dHGd_dY

 

 
PRIOR TO INSTALLATION: 

1.  To ensure compliance with local electric codes, please contact your local 
electrical inspector prior to installation 
2.  Do not install PUFP-CT prior to electrical inspector authorization. 
3. Installation should only be done by a licensed and bonded electrical contractor. 
4. All power must be turned off at its source prior to installation.  Failure to do so 
may result in injury or death. 
5. All non GFI PUFP-CT series must be connected to a GFCI circuit breaker.  Failure 
to do so will increase the risk of injury. 
6. If at any time water enters into the PUFP-CT, turn off power at its source and have 
the unit replaced by a licensed and bonded electrical contractor. 
7.  Always use 12 or 14 gauge STRANDED wire when possible.   

8.  LEW ELECTRIC ACCEPTS NO RESPONSIBILITY IF THE ABOVE CONDITIONS 
ARE NOT MET. 

 
 

REQUIRED TOOLS: 

Crimpling Pliers/ Wire Strippers, Philips Head Screw Driver, and Drill. 
 

INSTALLATION  

1. Prior to installation, a professional granite cutter should cut a 4 1/8” x 4 1/8” hole 
in the desired location of the PUFP-CT. 

** NOTE: When choosing a location, there 

must be a minimum of 1 inch of unobstructed clearance around each side of 
the hole inside the cabinet to allow the locking ring to screw onto the box.

 

2. Always use the supplied PUFP-PB plastic box.  Unscrew the locking nut from the 
bottom of the box and set aside.  
3.  Wiring must be completed before PUFP-PB is installed in countertop.  Place 
PUFP-PB box on top of countertop.  Inside the cabinet, place the lock nut through the 
wire.  Run wiring into the ½” knock out on the side of the box furthest away from 
the front of the countertop (preferred method).  Alternately, if ¾” knockouts are 
needed, use the knockouts in the bottom of the box furthest away from the front of 
the counter.  

If the knockouts are used closest to the front of the counter, the 

unit will not open. 

4. Strip the wires. 
5. Insert the stripped wire into the quick connect terminal box making sure that no 
striped wire is exposed. 