background image

Installing a controller

•  TO AVOID FIRE SHOCK OR DEATH; TURN OFF POWER at a circuit breaker 

or fuse panel and test that power is off before wiring in a Levven Controls 
product. Install and/or use Levven Controls in accordance with local electrical 
codes and regulations. Levven controllers are to be mounted in an electrical 
junction box of suitable size to satisfy the electrical code in your area. If you 
are unsure about any part of these instructions, consult a qualified electrician.

1) Connect wires to the controller (Fig 1)

a.  Connect the black power wire to the black wire of the controller
b.  Connect the black load wire to the red wire from the controller
c.  Connect the white wires from the power, load, and controller together

2) Mount the controller in an electrical box

a.  If installing the controller in a steel box, position the controller’s antenna 

wire outside the box for best reception. The antenna can be inside a plastic 
electrical box without affecting reception.

3) Turn power on

a.  When your connections are safely completed, energize the circuit by turning 

the power on at the panel.

b.  When powered, the LED status indicator on the controller will illuminate.

4) Group controllers together

a.  When two or more controllers are installed in a building, grouping controllers 

together is required to operate multiple controllers from one switch or using 
Levven Q for mobile device access and control. Only controllers with no 
previously saved group or pairing can join a group. 

b.  Press and release the ‘Pair’ button on one of the controllers in the group (or 

an ungrouped controller to start a new group). The LED on this controller 
(C1) will blink green.

c.  Press ‘Pair’ button on new controller being added to the group (C2). Its LED 

will blink green, and the first controller’s LED will blink red/green.

d.  Press ‘Pair’ button on the first controller (C1) again to complete the grouping. 

Its LED will flash green three times to confirm the group setting was saved.

5) How to reset a controller

a.  To clear switch pairings from a controller, press and hold the ‘Pair’ button for 

5 seconds. The LED will flash red three times to confirm.

b.  To remove a controller from a group, press and hold its ‘Pair’ button for 10 

seconds. The LED will flash red 10 times when the grouping is cleared.

c.  If using multiple controllers, group the controller before pairing it to a switch.

6) Pair switches and controllers

a.  Press and release the ‘Pair’ button on the controller. The LED on the 

controller will blink green. NOTE: If there is no pairing request received within 
60 seconds, the controller will quit the pairing procedure and its LED will 
return to a solid green.

b.  Squeeze then quickly release both ends of the switch to send a pairing code 

to the controller. The LED on the controller will blink green and red.

c.  Press and release the controller’s ‘Pair’ button to confirm the pairing. Its LED 

will flash green to confirm the pairing was saved successfully.

7) Mounting and using switches

a.  Levven Controls switches can be secured to any surface. Screws and 

anchors are provided to mount switches. Use decorator-style or Designer 
Series wall plates to finish the installation.

b.  Press and release the top of the switch rocker to send an “on” command to 

the controller. Press and hold the top to brighten the lights, or press and hold 
the bottom of the switch to dim the lights. Press and release the bottom of 
the switch rocker to send an “off” command.

Setting maximum and minimum brightness

1) Set the dimmer’s max brightness level

a.  Press and hold the top of the switch rocker to increase the light’s brightness. 

Fi

gur

e 1

Connecting

 the

 controller

 to

 the

 line/hot,

 load,

 and

 neutral

 wires.

 

Connectez le contrôleur avec les fils de la ligne actif,

 le

 

charge,

 et le neutre. Conexión del controlador de carga con los cables de la línea fase,

 carga y neutro.

If the light flickers, release the switch. Press and hold the bottom of the 
switch rocker to dim the light to a level where it does not flicker.

b.  2-click/double-click the button on the GDT15 controller. This sets the 

highest brightness. The GDT15 controller’s LED indicator will flash green to 
confirm the setting is saved.

2) Set the dimmer’s min brightness level

a.  Press and hold the bottom of the switch rocker to decrease the light’s 

brightness. If the light flickers, release the switch. Press and hold the top of 
the switch rocker and brighten the light to a level where it does not flicker.

b.  2-click/double-click the button on the controller. This sets the lowest 

brightness. The GDT15 controller’s LED indicator will flash green to confirm 
the setting is saved.

3) Reset the dimmer’s max/min brightness level to 

factory default

a.  3-click/triple-click the button on the GDT15 controller. NOTE: This will not 

clear any pairings or groupings in the controller’s memory. It only resets the 
brightness max/min settings to factory defaults.

Further Assistance

Support documents, videos, and 1-year limited manufacturer warranty 
information is available at levven.com/support. Levven Controls and GoConex by 
Levven are proudly designed and manufactured in Canada. Telephone Levven 
Electronics Ltd (780) 391-3000 or email [email protected].

Levven Controls GDT15 dimming controller / 
contrôleur

Input

 / Alimentation

: 85-265VAC, 50/60Hz 0.1~1.5A. Load

 / Chargement

1) Black wire connected to Line/Hot

File noir connecte avec la ligne actif
Cable negro conectado a la línea fase

2) Red wire connected to load

File rouge connecte avec le chargement
Cable rojo conectado a la linea de carga

3) White wire connected to both line and load neutrals

File blanc connecte avec les deux ligne et le chargement neutre
Cable blanco conectado a la dos líneas y a la carga neutra

To Load

Pour chargement
Para cargar

Antenna wire

Fil de l’antenne
Cable de antena

Electrical box

Boîte de jonction
Caja de conjunción

LED status indicator

Indicateur DEL
Indicador DEL

‘Pair’ button

Boutton “Jumelage”
Botón “Acoplar”

From Line Power

Pour ligne d’alimentation
Entrada linea de alimentación

Line 

/ Ligne / Línea

Neutral (white) 

/ Neutre (blanc) / Neutro (blanco)

Hot (black) 

/ Actif (noir) / Fase (negro)

Load

Charge

Carga

Red

Rouge

Rojo

White

Blanc

Blanco

Black

Noir

Negro

1.5A max (resistive lighting

 / résistance de l’éclairage

). Indoor use only

 / 

Utilisation intérieur seulement

. Operating temperature range

 / S’opère à une 

température ente 

-40°C – 50°C. FCC ID : 2ADH9-G2CF. This device complies 

with Part 15 of the FCC Rules. Operation is subject to the following two 
conditions: (1) this device may not cause harmful interference, and (2) this 
device must accept any interference received, including interference that may 
cause undesired operation. IC ID: 12453A-G2CF. CAN ICES-3(B)/NMB-3(B). 
Certified to

 / Certifié à 

CSA STD C22.2 #14 Conforms to

 / Conforme à 

UL STD 

244A & 508

Levven Controls GSW switch

FCC ID: 2ADH9-GSW    IC ID: 12453A-GSW

FR

 Installation du contrôleur Levven

•  POUR ÉVITER LES DÉCHARGES ÉLECTRIQUES OU LA MORT; COUPEZ 

L’ALIMENTATION au niveau d’un disjoncteur ou d’un panneau de fusibles et 
vérifiez qu’il est bien hors tension avant de brancher des produits Levven. 
Installez et/ou utilisez Levven en accord avec le code local d’électricité et ses 
règlements. Le contrôleur Levven doit être inséré dans une boîte de jonction 
appropriée et en conformité avec le code électrique de votre région. Si vous 
n’êtes pas sûr de bien comprendre une partie de ces instructions, consultez 
un électricien qualifié.

1) Vous aurez besoin de fils pour installer le 

contrôleur Levven (Fig. 1)

a.  Connectez le fil d’alimentation noir au fil noir du contrôleur.
b.  Connectez le fil de charge noir au fil rouge du contrôleur.
c.  Connectez ensemble les fils blancs de l’alimentation, de la charge et du 

Отзывы: