WIRING DIMMER:
Connect wires per WIRING DIAGRAM as follows:
•
Green or bare copper wire in wall box to Green dimmer lead.
•
Line Hot wall box wire to Black dimmer lead.
•
Load wall box wire to Red dimmer lead.
•
Yellow/Red dimmer lead should have Red insulation label affixed.
NOTE:
If insulating label is not affixed to Yellow/Red dimmer
lead, use electrical tape to cover.
• Proceed to Step 5.
• Pull off pre-cut insulation from dimmer leads.
• Make sure that the ends of the wires from the wall box are
straight (cut if necessary)
.
• Remove insulation from each wire in the wall box as shown.
•
For Single-Pole Application, go to Step 4a.
•
For 3-Way Coordinating Remote (no LEDs) Application, go
to Step 4b.
WARNINGS AND CAUTIONS:
• To be installed and/or used in accordance with appropriate electrical codes and regulations.
• If you are unsure about any part of these instructions, consult a qualified electrician.
• To avoid overheating and possible damage to this device and other equipment, do not install to control a receptacle, fluorescent lighting, a motor- or a transformer-operated appliance.
• Use with incandescent or 120V halogen fixtures only.
• Vizia™ RF dimmers are not compatible with standard 3-way or 4-way switches. They must be used with compatible Vizia™ or Vizia™ RF remotes for multi-location dimming.
• Use only one (1) Vizia™ RF dimmer in a multi-location circuit with up to 9 Vizia™ coordinating remotes without LEDs or Vizia™ RF controllers. The remote(s) will turn the light on at the
brightness level selected at the dimmer.
WARNINGS AND CAUTIONS:
• Dimmer may not operate with dioded lamps (Sylvania Designer 16™ or Philips PAR-16™).
• Total minimum load must exceed 40W.
• Dimmer may feel warm to the touch during normal operation.
• Recommended minimum wall box depth is 2-1/2”.
• Maximum wire length from dimmer to all installed remotes cannot exceed 300 ft.
• Disconnect power at circuit breaker or fuse when servicing, installing or removing fixture.
• Use this device only with copper or copper clad wire. With aluminum wire use only devices marked CO/ALR or CU/AL.
IMPORTANT:
For 3-Way applications, note that one of the screw
terminals from the old switch being removed will usually be a
different color (Black) or labeled Common. Tag that wire with
electrical tape and identify as the common (Line or Load) in both the
dimmer wall box and remote wall box.
INSTALLING YOUR DIMMER
NOTE:
Use check boxes when Steps are completed.
√
Single-Pole Wiring Application:
Step 4a
Step 4b cont’d
WIRING DIMMER:
Connect wires per WIRING DIAGRAM as follows:
NOTE:
When using the coordinating remote without LEDs, the
dimmer can be installed on either the Line or Load side of the
3-way circuit.
NOTE:
Maximum wire length from dimmer to all installed remotes
cannot exceed 300 ft.
•
Green or bare copper wire in wall box to Green dimmer lead.
•
Line Hot (common) wall box wire identified (tagged) when
removing old switch to Black dimmer lead.
•
First Traveler wall box wire to Red dimmer lead
(note wire
color)
. This traveler from the dimmer must go to the terminal
screw on the remote marked “RD”.
•
Remove Red insulating label from Yellow/Red dimmer lead.
•
Second Traveler wall box wire to Yellow/Red dimmer lead
(note wire color)
. This traveler from the dimmer must go to
the terminal screw on the remote marked “YL/RD”.
WIRING COORDINATING REMOTE:
Connect wires per WIRING DIAGRAM as follows:
NOTE:
Maximum wire length from dimmer to last remote is 300ft.
•
Green or bare copper wire in wall box to Green terminal screw.
•
Load wall box wire identified (tagged) when removing old
switch to terminal screw marked “BK”.
•
First Traveler wall box wire
(note color as above)
to terminal
screw marked “RD”. This traveler from the remote must go to
the Red dimmer lead.
•
Second Traveler wall box wire
(note color as above)
to
terminal screw marked “YL/RD”. This traveler from the remote
must go to the Yellow/Red dimmer lead.
•
Remote terminal screw marked “WH” should have White
insulation label affixed.
NOTE:
If insulating label is not affixed
to terminal screw marked “WH”, use electrical tape to cover.
• Proceed to Step 5.
More than
Cat. No.
Single
Two Devices 2 Devices
RZI1Ø
1000W
800W
650W
MAXIMUM LOAD PER DIMMER FOR MULTI-DEVICE
Compatible with
enabled products!
TM
Remove all
inner side
sections
Do not
remove
outer side
sections
WIRE NUT / # OF CONDUCTOR
COMBINATION CHART
1- #12 w/ 1 to 3 #14, #16 or #18
2- #12 w/ 1 or 2 #16 or #18
1- #14 w/ 1 to 4 #16 or #18
2- #14 w/ 1 to 3 #16 or #18
For non-standard wiring applications, refer
to Wire Nut and Conductor Size Chart
Dimmer
Black
Black
Load
White
Yellow/Red
Hot (Black)
Neutral (White)
Line
120VAC, 60Hz
Red
Green
Ground
Insulating
Label
3-Way Wiring with Coordinating
Dimming or Switching Remote (no LEDs)
Application:
(Coordinating Dimming Remote Depicted)
Bk
YL/RD RD
4
3
2
5
Black
Green
Red
Yellow/
Red
1
Coordinating remote
2
4
3
5
1
Dimmer
YL/RD
RD
WH
BK
Do not use for
incandescent
applications.
Green
Ground
Green
Ground
Black
Load
White
Red
Red
Yellow/
Black Hot (Black)
Neutral (White)
Line
120VAC, 60Hz
Coordinating Remote (no LEDS)
Dimmer
Tools needed to install your Dimmer:
Slotted/Phillips Screwdriver
Electrical Tape
Pliers
Pencil
Cutters
Ruler
Changing the color of your Dimmer:
Your Dimmer may include three color options. The Dimmer ships
with the White frame attached. To change color of frame, proceed
as follows:
Installing Dimmer by itself or with other devices:
If installing Dimmer in a single device application, proceed with the
INSTALLING YOUR DIMMER
section. If installing Dimmer in a
multi-device application, proceed as follows:
MULTI-DEVICE APPLICATION:
In multi-dimmer installations, the reduction of the dimmer’s capacity
is required. Refer to the chart for maximum load per dimmer.
Step 4b
4
3
2
1
Black
Red
Green
Yellow/Red
Dimmer
Insulating Label:
This wire is used in 3-way installations only.
For single pole installations, do not remove this label.
Strip Gage
(measure bare wire
here or use gage on
back of the dimmer)
5/8”
(1.6 cm)
cut
(if necessary)
Step 3
Preparing and connecting wires:
This dimmer can be wired using side wire terminal
screws or through backwire openings. Choose
appropriate wire stripping specifications accordingly.
Step 2
Identifying your wiring application
(most common):
NOTE:
If the wiring in the wall box does not resemble
any of these configurations, consult a qualified
electrician.
2
4
3
1
2
4
1
5
3
3-Way
1.
Line or Load
(See important
instruction
below)
2.
Neutral
3.
Ground
4.
First Traveler
– note color
5.
Second Traveler
– note color
Single-Pole
1.
Line (Hot)
2.
Neutral
3.
Ground
4.
Load
Step 1
WARNING:
TO AVOID FIRE, SHOCk, OR DEATH;
TURN OFF POWER
at circuit breaker or fuse and test
that power is off before wiring!
Push in
side at tab
to release
Line up tabs
and press in
side to attach
INTRODUCTION
Leviton’s Vizia
TM
RF components are designed to communicate
with each other via Radio Frequency (RF) to provide remote
control of your lighting. Using RF technology allows Leviton
to provide the greatest signal integrity possible. Each module
in Leviton’s Vizia
TM
RF component line is a Z-Wave
TM
enabled
device. In a Z-Wave
TM
network, each device is designed to act
as a router. These routers will re-transmit the RF signal from
one device to another until the intended device is reached. This
ensures that the signal is received by its intended device by
routing the signal around obstacles and radio dead spots. The
Scene Capable Plug-in Lamp Dimming Module is compatible with
any Z-Wave™ enabled network, regardless of the manufacturer
and can also be used with other devices displaying the Z-Wave™
logo.
CAUTION:
Remember to exercise good common sense when using the
Timer features of your remote, especially when scheduling
unattended devices. There can be some unexpected
consequences if not used with care. For example, an empty
coffee pot can be remotely turned on. If that should happen, your
coffee pot could be damaged from overheating. If an electric
heater is turned on by remote control while clothing is draped
over it, a fire could result.
DO NOT USE
the remote for the control
of high power heating appliances such as portable heaters. This
device will not control lighting that is used with electronic low-
voltage and high frequency power supply transformers, nor high
pressure discharge lamps (HID lighting). This includes mercury-
vapor, sodium vapor and metal halide lamps.
• Soft fade ON/OFF
• Scene capable
• ON/OFF LED and Brightness level LED
• Two way communication
• RF reliability
• Ease of installation – No new wiring
• Compatible with other Z-Wave™ enabled devices
FEATURES