B)

  If using RZCPG Programmer/Remote, you will be prompted to place 

4-Scene controller into programming mode. 

C)

  To access Program mode, press and hold 

buttons 1 and 3 

(refer to figure)

. Wait 

5 seconds until the LED turns Amber. 

Release the buttons and the LED will blink 

Amber. You are now in Programming mode.

 

NOTE:

 If the LED on the 4-scene controller 

turns solid Red while including, there has 

been a communication error. 

D)

  While standing close to the 4-Scene 

controller (approximately 2-5 ft.), press the 

center button on the Programmer/Remote 

to <Include> device in the network. 

NOTE:

 

Only one device may be included at any 

time.

E)

  The Primary Programmer/Remote will assign a Home ID, Node ID, 

and Name for this device.

 

NOTE:

 This information will be stored in the Programmer/Remote to 

be used for future reference.

 

NOTE:

 You may name or edit the node of this device at this time.

F)

 

The 4-Scene controller is now installed in the network

.

G)

  After all devices are included into the network, the controller must 

be updated to allow proper network function. To update controller 

proceed as follows:

 

•   If using a non-Leviton Programmer/Remote, refer to the 

Programmer/Remote instruction sheet for updating controller.

 

•   If using Leviton Z-Wave

TM

 Programmer/Remote, Cat. No. RZCPG, 

press the Menu button and scroll down to System Setup. Press 

the center button to select System Setup Menu. Press the center 

button to select Network. Press the center button to select 

Update "cntrl". When prompted, press desired button on 4-Scene 

controller.

 

•   Wait until the RZCPG Programmer/

Remote confirms completion. Update 

is done.

NOTE:

 If the 4-Scene controller has 

been successfully Included in the 

network and the user tries to Include 

it again without first excluding it from the 

network, the controller will retain the first 

node ID it had received and ignore the 

second.

WARNINGS AND CAUTIONS

:

•  ON/OFF LED for remote load control. 
•  To be installed and/or used in accordance with appropriate electrical codes and regulations.
•  If you are unsure about any part of these instructions, consult a qualified electrician.
•  Vizia

TM

 RF RZCS4 controller does not control the load, but provides scene applications to operate with Vizia

TM 

RF switches.

•  Recommended minimum wall box depth is 2-1/2".

WARNINGS AND CAUTIONS

:

•  Can call up four (4) scene ON/OFF with advanced Programmer/Remote (see RZCPG). 
•  Disconnect power at circuit breaker or fuse when servicing, installing or removing fixture.
•  Use this device only with copper or copper clad wire. With aluminum wire use only devices marked CO/ALR or CU/AL.

4-Scene Controller

Cat. No. RZCS4

120VAC, 60Hz

INSTAllATION INSTRUCTIONS

DI-000-RZCS4-00C

 Tools needed to install your 4-Scene Controller:

Slotted/Phillips Screwdriver 

Electrical Tape 

Pliers 

 

Pencil 

 

 

Cutters 

 

Ruler

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

WARNING: 

TO AVOID FIRE, SHOCK OR DEATH; TURN 

OFF POWER 

at circuit breaker or fuse and test that power is off 

before wiring!

 

Step 1

 

Step 3

Compatible with

enabled products!

TM

Preparing and connecting wires:

This 4-Scene controller can be wired using side wire terminal 

screws or through backwire openings. Choose appropriate wire 

stripping specifications accordingly.

•  Make sure that the ends of the wires from the wall box are 

straight (cut if necessary).

5/8" 

(1.6 cm)

Strip Gage 

(measure bare 

wire here)

Cut 

(if necessary)

Back Wire (either hole may be used) 

Back wire openings use #14-12 AWG 

solid wire copper only

Side Wire Connection 

Side wire terminals accept 

#14 AWG 

solid wire copper only

.

WIRING 4-SCENE CONTROllER:

Connect wires per WIRING DIAGRAM as follows:

•  Green or bare copper wire in wall box to Green terminal screw.

•  Line Hot wall box wire to terminal screw marked "BK".

•  Line Neutral wall box wire to terminal screw marked "WH".

 

Step 6 cont'd

Programmer/Remote 

Cat. No. RZCPG

ON

ON

ON

ON

OFF

OFF

OFF

OFF

Menu 

Button

Center 

Button

Wiring Application:

(OT"LACK 

.EUTRAL7HITE 

,INE

6!#(Z

"+

7(

'REEN

'ROUND

3CENE#ONTROLLER

 

Step 4

2

3

1

1.

  Line (Hot)

2.

  Neutral

3.

  Ground

Identifying your wiring application (most common):

NOTE:

 If the wiring in your wall box does not resemble this 

configuration, consult a qualified electrician.

 

Step 2

 INTRODUCTION

Leviton’s Vizia

TM

 RF components are designed to communicate with 

each other via Radio Frequency (RF) to provide remote control of your 

lighting. Using RF technology allows Leviton to provide the greatest 

signal integrity possible. Each module in Leviton’s Vizia

TM

 RF component 

line is a Z-Wave

TM

 enabled device. In a Z-Wave

TM

 network, each device 

is designed to act as a router. These routers will re-transmit the RF signal 

from one device to another until the intended device is reached. This 

ensures that the signal is received by its intended device by routing the 

signal around obstacles and radio dead spots. The 4-Scene Controller 

is compatible with any Z-Wave

TM

 enabled network, regardless of the 

manufacturer and can also be used with other devices displaying the 

Z-Wave

TM

 logo.

•   This is a Z-Wave

TM

 Controller

•   Scene control without traveler wires 
•   Can call 4 scenes
•   ON/OFF LED 
•   Two way communication
•   RF reliability 
•   Ease of installation – No new wiring
•   Compatible with other Z-Wave

TM

 enabled devices

 FEATURES

 

Step 6

Including 4-Scene Controller into Z-Wave

TM

 

Network:

NOTES:

• 

If using a non-Leviton Programmer/Remote, refer to the Programmer/

Remote instruction sheet.

• 

4-Scene controllers incuded into a Z-Wave

TM

 network must be updated 

after you have included all other devices.

A)

  If using a Leviton Z-Wave

TM

 Programmer/Remote, Cat. No. RZCPG, 

press the Menu button and scroll down to System Setup. Press the 

center button to select System Setup Menu. Press the center button to 

select Network. Press the center button to <Include Node>.

Changing the color of your 4-Scene Controller:

Your 4-Scene controller includes three color options. The controller ships 

with the White frame attached. To change color of frame, proceed as 

follows:

line up tabs 

and press in 

side to attach

Push in 

side at tab 

to release

After frame is removed, remove existing push buttons and replace them 

with desired color change push buttons. To change the DIM/BRIGHT 

button, before mounting frame, press out DIM/BRIGHT button (bottom) 

from back of frame and press in from front of frame new DIM/BRIGHT 

button. To make IR capable, replace with a DIM/BRIGHT button that has 

the IR window. 

INSTAllING YOUR 4-SCENE CONTROllER

NOTE:

 Use check boxes           when Steps are completed.

•  Position all wires to provide room in 

outlet wall box for device.

•  Ensure that the word “TOP” is facing up 

on device strap.

•  Partially screw in mounting screws in 

wall box mounting holes.

 

NOTE:

 Dress wires with a bend as 

shown in diagram in order to relieve 

stress when mounting device.

•  Restore power at circuit breaker or fuse. 
•  LED should turn ON.
 

If lED does not turn ON, refer to the 

TROUBlESHOOTING section.

Testing your 4-Scene Controller prior to 

mounting in wall box:

 

Step 5

Bl