![Leviton RZCS1 Скачать руководство пользователя страница 1](http://html1.mh-extra.com/html/leviton/rzcs1/rzcs1_installation-instructions_1886370001.webp)
B)
If using RZCPG Programmer/Remote, you will be prompted to place
1-scene controller into programming mode.
C)
To access Program mode, engage the air gap switch by gently
pulling the bottom of the push pad until it lifts out of the frame and a
click is heard
(refer to figure)
. Wait 5 seconds and then press the
push pad back into the frame and hold push pad until the LED turns
Amber. Release the push pad and the LED should blink Amber. You
are now in Programming mode.
NOTE:
If the LED on the 1-scene controller turns solid Red while
including, there has been a communication error.
D)
While standing close to the 1-scene
controller (approximately 2-5 ft.), press
the center button on the Programmer/
Remote to <Include> device in the
network.
NOTE:
Only one device may
be included at any time.
E)
The Primary Programmer/Remote
will assign a Home ID, Node ID, and
Name for this device.
NOTE:
This information will be stored
in the Programmer/Remote to be used
for future reference.
NOTE:
You may name or edit the node
of this device at this time.
F)
The 1-scene controller is now
installed in the network
.
G)
After all devices are included into the
network, the controller must be updated to allow proper network
function. To update controller proceed as follows:
• If using a non-Leviton Programmer/Remote, refer to the
Programmer/Remote instruction sheet for updating controller.
• If using Leviton Z-Wave
TM
Programmer/Remote, Cat. No. RZCPG,
press the Menu button and scroll
down to System Setup. Press the
center button to select
System Setup Menu. Press the
center button to select Network.
Press the center button to select
Update "cntrl". When prompted, press
push pad on the 1-scene controller.
• Wait until the RZCPG Programmer/
Remote confirms completion.
Update is done.
NOTE:
If the 1-scene controller has
been successfully Included in the
network and the user tries to Include
it again without first excluding it from
the network, the controller will retain
the first node ID it had received and
ignore the second.
WARNINGS AND CAUTIONS
:
• ON/OFF LED for remote load control.
• To be installed and/or used in accordance with appropriate electrical codes and regulations.
• If you are unsure about any part of these instructions, consult a qualified electrician.
• Vizia™ RF RZCS1 1-Scene Controller does not control the load, but provides 3-way or 4-way applications to operate with Vizia
TM
RF switches.
• Recommended minimum wall box depth is 2-1/2".
WARNINGS AND CAUTIONS
:
• No traveler wires are needed. Remote controls via radio frequency (RF) technology.
• Can call one (1) scene ON/OFF with advanced Programmer/Remote (see RZCPG).
• Disconnect power at circuit breaker or fuse when servicing, installing or removing fixture.
• Use this device only with copper or copper clad wire. With aluminum wire use only devices marked CO/ALR or CU/AL.
1-Scene Controller/
Matching Switch Remote
Cat. No. RZCS1
120VAC, 60Hz
INSTAllATION INSTRUCTIONS
DI-000-RZCS1-00C
Tools needed to install your 1-Scene Controller:
Slotted/Phillips Screwdriver
Electrical Tape
Pliers
Pencil
Cutters
Ruler
Changing the color of your 1-Scene Controller:
Your 1-scene controller includes three color options. The controller ships
with the White frame attached. To change color of frame, proceed as
follows:
line up tabs
and press in
side to attach
Push in
side at tab
to release
INSTAllING YOUR 1-SCENE CONTROllER
NOTE:
Use check boxes when Steps are completed.
/.
/&&
/.
/&&
/.
/&&
/.
/&&
/.
/&&
/.
/&&
/.
/&&
/.
/&&
/.
/&&
/.
/&&
/.
/&&
/.
/&&
WARNING:
TO AVOID FIRE, SHOCK OR DEATH; TURN
OFF POWER
at circuit breaker or fuse and test that power is off
before wiring!
Step 1
Compatible with
enabled products!
TM
Step 3
Preparing and connecting wires:
This 1-scene controller can be wired using side wire terminal
screws or through backwire openings. Choose appropriate wire
stripping specifications accordingly.
• Make sure that the ends of the wires from the wall box are
straight (cut if necessary).
5/8"
(1.6 cm)
Strip Gage
(measure bare
wire here)
Cut
(if necessary)
Side Wire Connection
Side wire terminals accept #14
AWG
solid wire copper only
.
Back Wire (either hole may be used)
Back wire openings use #14-12 AWG
solid wire copper only
.
WIRING 1-SCENE CONTROllER:
Connect wires per WIRING DIAGRAM as follows:
• Green or bare copper wire in wall box to Green terminal screw.
• Line Hot wall box wire to terminal screw marked "BK".
• Line Neutral wall box wire to terminal screw marked "WH".
•
Proceed to Step 5.
• Position all wires to provide room in
outlet wall box for device.
• Ensure that the word “TOP” is facing up
on device strap.
• Partially screw in mounting screws in
wall box mounting holes.
NOTE:
Dress wires
with a bend as
shown in diagram
in order to relieve
stress when
mounting device.
• Restore power at circuit breaker or fuse.
• LED should turn ON.
If lED does not turn ON, refer to the
TROUBlESHOOTING section.
Testing your 1-Scene Controller prior to
mounting in wall box:
Step 5
Step 6 cont'd
Cat. No. RZCPG
1
ON
2
ON
3
ON
4
ON
OFF
OFF
OFF
OFF
Menu
Button
Center
Button
Gently lift bottom of
push pad out
Wiring Application:
Hot (Black)
Neutral (White)
Line
120VAC, 60Hz
BK
WH
Green
Ground
1-Scene Controller
Step 4
2
3
1
2
1.
Line (Hot)
2.
Neutral
3.
Ground
Identifying your wiring application (most common):
NOTE:
If the wiring in your wall box does not resemble this
configuration, consult a qualified electrician.
Step 2
INTRODUCTION
Leviton’s Vizia
TM
RF components are designed to communicate with
each other via Radio Frequency (RF) to provide remote control of your
lighting. Using RF technology allows Leviton to provide the greatest
signal integrity possible. Each module in Leviton’s Vizia
TM
RF component
line is a Z-Wave
TM
enabled device. In a Z-Wave
TM
network, each device
is designed to act as a router. These routers will re-transmit the RF signal
from one device to another until the intended device is reached. This
ensures that the signal is received by its intended device by routing the
signal around obstacles and radio dead spots. The 1-Scene Controller/
Matching Switch Remote is compatible with any Z-Wave™ enabled
network, regardless of the manufacturer and can also be used with other
devices displaying the Z-Wave™ logo.
• This is a Z-Wave
TM
Controller
• 3-way or 4-way control without traveler wires
• Can call 1 scene
• ON/OFF LED
• Two way communication
• RF reliability
• Ease of installation – No new wiring
• Compatible with other Z-Wave™ enabled devices
FEATURES
Step 6
Including 1-Scene Controller into Z-Wave
TM
Network:
NOTES:
•
If using a non-Leviton Programmer/Remote, refer to the Programmer/
Remote instruction sheet.
•
1-scene controllers included into a Z-Wave
TM
network must be updated
after you have included all other devices.
A)
If using a Leviton Z-Wave
TM
Programmer/Remote, Cat. No. RZCPG,
press the Menu button and scroll down to System Setup. Press the
center button to select System Setup Menu. Press the center button to
select Network. Press the center button to <Include Node>.