4 Speed Quiet Ceiling Fan/Light Control – Single Pole (One location)
Cat. No. RTDØ1-1Ø,
Fan Control
Rated: 1.5A-120VAC, 60Hz
Full Range Dimming Incandescent Lamp Load
Rated: 300W-120VAC, 60Hz
INSTALLATION INSTRUCTIONS
DI-000-RTD01-02B
Tools needed to install your Fan Speed
Control:
Slotted/Phillips Screwdriver
Electrical Tape
Pliers
Pencil
Cutters
Ruler
Color Change Option:
If a color change kit is provided with your device,
proceed with the following step if you need to change
the color. Otherwise, proceed with the "Installing
Fan Speed/Light Control by itself or with other
devices" section.
Changing the color of your Fan Speed/
Light Control
Your Fan Speed Control includes two color options. The
Control ships with the White frame attached. To change
color of frame, proceed as follows:
Installing Fan Speed/Light Control by
itself or with other devices:
If installing Control in a single device application,
proceed with the MULTI-FAN CONTROL section. If
installing Control in a multi-device application,
proceed as follows:
MULTI-DEVICE APPLICATION
NOTE: There is NO derating necessary for multi-gang
installations of this Fan Speed Control.
MULTI-FAN CONTROL
Any number of fans of the same type may be
controlled by a single fan speed control provided that
the total amperage of the fans do not exceed the
amperage of the fan speed control.
INSTALLING YOUR FAN SPEED/LIGHT
CONTROL
NOTE: Use check boxes when Steps are
completed.
WARNING:
To avoid fire, shock, or
death; TURN OFF POWER at circuit
breaker or fuse and test that power is off
before wiring!
Step 1
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
WARNINGS AND CAUTIONS:
• To be installed and/or used in accordance with appropriate electrical codes
and regulations.
• If you are unsure about any part of these instructions, consult a qualified
electrician.
• To avoid overheating and possible damage to this device and other equipment,
do not install to control a receptacle, fluorescent lighting, a motor- or a
transformer-operated appliance other than appropriate ceiling fans and
incandescent lamps.
WARNINGS AND CAUTIONS:
• To reduce the risk of fire or electrical shock, this control is to be used with
ceiling fans that are marked as suitable for use with solid-state fan speed control
and is rated 120VAC, total load 1.5 amperes maximum.
• For use on ceiling paddle fans with split-capacitor or shaded pole motors only.
Please refer to manufacture's instructions or rating label on the motor to
confirm type. Use with any other types of motors or equipment may cause
overheating and/or damage to the motors or equipment.
• Disconnect power at circuit breaker or fuse when servicing fixture.
• Use this device only with copper or copper clad wire. With aluminum wire use
only devices marked CO/ALR or CU/AL.
Strip 5/8"
(1.6 cm)
Cut
(if necessary)
√
Single-Pole Wiring Application:
Preparing wires:
Black
Red
Neutral
Green
Ground
Yellow
O
F
F
M
A
X
H
I M
E
D LO
O
F
F
M
A
X
HI
M
ED LO
Push in side at tab
to release. Remove
frame and knob.
Press on knob. Line up
tabs on back of frame and
press in side to attach
Strip Gage
•
Pull off pre-cut insulation from Control leads.
•
Make sure that the ends of the wires from the
wall box are
straight (cut if necessary).
•
Remove 5/8" (1.6 cm) of insulation from each
wire in the wall box (shown).
Step 3
Step 2
Insert wires
straight then twist
clockwise
Electrical
Tape
5/8"
(1.6 cm)