background image

Engineered for Safe and Easy Operation.

Leviton Mini Softlite is a versatile, portable soft fill light for 
photographic and studio applications. These instructions will help you 
become more familiar with your fixture.

Functions

Lamp Installation

Disconnect the unit from power. Loosen the thumbscrews on the light stick 
assembly and move the lampholder brackets away from the silver reflectors. 
Install the lamp by centering one end within a contact, apply force to that 
contact compressing the lampholder spring. The opposite lamp end can be 
centered within its lampholder. Release the lamp, and it should be held firmly 
in place. Pivot the lamp assemblies into the small reflectors, and tighten the 
thumbscrews firmly.

Please do not touch the quartz envelope during installation. Double ended 
lamps should be installed with protective gloves or insulation around the 
lamp, like a tissue on the lamp perimeter which can be removed after lamp is 
installed. If you touch the envelope, REMOVE the lamp from the fixture and 
clean with isopropyl (rubbing) alcohol and a clean, lint free cloth.

The Mini Softlite is UL listed to 2000 watts, using 2-1000 watt lamps maximum. 
Higher wattage lamps used in the Mini Softlite void manufacturing warranties.

Warnings

1.

   The Mini Softlite is a professional lighting fixture. The fixture housing 

becomes hot and should not be touched during operations.

2.

   The fixture uses high intensity tungsten halogen lamps which can implode. 

The primary cause of lamp implosions is fingerprints or other foreign debris 
on the lamp. Proper fixture care will minimize risk.

3.

   Do not operate continuously for more than 8 hours with 1000-watt lamps. 

Fixture may overheat.

Maintenance

Reflector

Both the main white reflector and the silver auxiliary are cleaned with isopropyl 
(rubbing) alcohol and a clean, lint free cloth. Strong alkaline or acidic cleaners 

MUST NOT

 be used.

General Maintenance

Periodically check that all screws and wire terminations are secured firmly. Also 
check that the strain relief is fitted properly inside the wiring compartment, and 
the cable is not frayed.

If lampholder becomes pitted or looses spring tension, it must be replaced. 
To replace, remove the appropriate lampholder bracket from the light stick 
assembly by loosening both thumbscrews. Drill out the rivet, replace the 
lampholder and reapply rivets or 4-40 screws with lock nuts.

Color

Lee Color Effect Filters are recommended for all filter applications. These filters 
are available in over 175 colors, color corrections, and diffusion selections. Lee 
Filters are available in both 21” x 4” sheets and 25’ x 4’ rolls.

DI-00X-000MS-00A

USER GUIDE

Softlite

Mini

Part No. 

 

Description

  

Difusion/Color 

frame

  

Compact 

Stand

000-A00SC-000   

Safety cable, 30” long

000-A00CC-000  

C-clamp

000-AMSEC-000  

Egg Crate

Accesories

 Part 

 

 

Color 

Life

Watts No. 

ANSI 

Temp. 

(Hrs.)

1000 176-021 

FCM 

3200°K 

500

800 

9

 176-027 

EME 

3200°K 

250

750 176-026 

EMD 

3200°K 

500

500 176-024 

FDN 

3050°K 

500

500 176-019 

EJD 

3200°K 

10000

1000 

9

 7786R/64583 

   

3200°K 

200

800 

9

 13477R/P2-11 

   

3200°K 

150

625 

9

 P2-15 

   

3200°K 

75

500 

9

 64702/7785R/K-1 

   

2900°K 

2000

300 

9

 12113R/K-9 

   

2900°K 

2000

 

9

 (220 or 240 Volt lamps)

Recommended Lamps

With 2-1000 Watt, FCM lamp, Model No. 176-021

For illumination at any distance, divide 11,200 by the distance squared.

For field diameter at any distance, multiply that distance by 1.3 for beam 
and 2.9 for field.

   Efficiency 

Flood Lumens 

Candlepower

   Beam 

9,693 (17.3%) 

11,200

   Field 

22,274 (39.8%)

Photometric Performance

Peak Focus

Beam Angle

(50% of max. int.)

Field Angle

(10% of max. int.)

10

13

19.5

26

32.5

114

50

28

18

15

20

25

6

5

4

5.3

700

6.7

448

7.9

311

3

4

1244

Distance (feet)

Field Diameter (feet)

Illumination at
Beam Center (footcandles)

Illumination at
Beam Center (lux)

Field Diameter (meters)

Distance (meters)

WEB 

VERSION

Отзывы: