background image

0-10VDC Low Voltage RF Wall Dimmer

Cat. No. ZS057-ALZ, Ratings: 24VDC, 20mA

INSTALLATION INSTRUCTIONS

ENGLISH

DI-003-ZS057-02A

Before Installation

• Install into any single-gang device back box. 
• Supports multi-gang installations.
• Requires Decora

®

 faceplate, sold separately.

• Devices use 0-10VDC low voltage control wires which may be installed as Class 1 or Class 2. 

IMPORTANT:

 If installed as Class 2, all devices in the circuit must be Class 2 rated and this dimmer must be wired per instructions below.

0-10V Dimming Installation

For 0-10V control wiring: connect the VIOLET wire to the +0-10V line and the GRAY wire to the 0-10V COMMON using Class 1 or Class 2 wiring 

PHWKRGVDVLQGLFDWHGLQWKHVHLQVWUXFWLRQVEDOODVW¿[WXUHGULYHULQVWUXFWLRQVRUEDOODVW¿[WXUHGULYHUODEHOPDUNLQJV2EVHUYHDOOUHTXLUHPHQWVRIDQ\

authority having jurisdiction with respect to wire type, sleeving, isolation methods, and the like. Separation must be provided if Class 2 circuit is installed 

WRJHWKHUZLWK&ODVVUHIHUWR1(&FRGHIRUDOORZDEOHPHWKRGVDQGVSHFL¿FDWLRQV

NOTE THE FOLLOWING:

‡6LOLFRQHWXELQJVKRXOGEH157/8/&6$(7/UHFRJQL]HGRUHTXLYDOHQWWRSURYLGHPHFKDQLFDOVHSDUDWLRQHTXDOWR´LQDLU

• Connectors joining 0-10V control wires should be approved LISTED CONNECTORS.
• Wire connectors and wire tubing should be provided by the installation contractor.

WARNINGS

•  

TO AVOID FIRE, SHOCK, OR DEATH; TURN OFF POWER AT CIRCUIT 
BREAKER OR FUSE AND TEST THAT POWER IS OFF BEFORE WIRING!

•  To be installed and/or used in accordance with appropriate electrical codes 

and regulations.

•  If you are unsure about any part of these instructions, consult an electrician.

CAUTIONS

•  Use this device with 

copper or copper clad wire only.

•  For indoor applications only.
•  Save these instructions.

To release, push sides.

Line up and press in to attach.

WARNING

TO AVOID FIRE, SHOCK, OR DEATH; TURN OFF 

POWER at circuit breaker or fuse and test that power is off 
before wiring!

1.

 

Strip wires 3/4 in. and connect as per wiring diagram. Ensure 

ZLUHVDUH¿UPO\DWWDFKHGDQGWKHUHLVQRH[SRVHGFRSSHU

2.

 

Gently place the wires and your device into the wall box and attach 

with screws provided.

 

4.

 

If desired, change switch color.

5.

 

Install Decora faceplate.

Same Class Wiring Installation Shown

White

Orange/Yellow

Black

Red

Ground

Blue

Green

Violet

Gray

Black

ZS057-ALZ

BACKBOX

PURPOSE

BLACK

RED

+24VDC

WHITE

BLACK

COMMON

BLUE

ORANGE/YELLOW

LOCAL SWITCH 

GREEN

GREEN

GROUND

VIOLET

VIOLET

9',00,1*

GRAY

GRAY

&20021',00,1*

3.

 

5HVWRUHSRZHUDQGWHVW212))RSHUDWLRQ6WDWXVOLJKWVKRXOGEULHÀ\
ÀDVK*5((1ZKHQWKHWRSRUERWWRPSDGGOHLVSUHVVHG

Lighting

Load

Powerpack
OPP20-0D2

Zone A

Line

BLU

BLU (SIG)

RED (+V/+24V)

BLK (COM)

BLU/WHT (MANUAL ON)

ORG/YEL (LOCAL SW INPUT)

VIO

GRY

BLU

BLK

WHT

Low Voltage

Occupancy

Sensor

BLU

BLK

WHT

Lighting

Circuit

Line Feed

NEU

WEB 

VERSION

Отзывы: