Leviton Decora Sureslide 6629-3, 1.5A Скачать руководство пользователя страница 1

WARNINGS AND CAUTIONS:

•   To be installed and/or used in accordance with appropriate electrical codes and regulations.
•   If you are not sure about any part of these instructions, consult a qualified electrician.
•   To avoid overheating and possible damage to this device and other equipment, do not install to control a receptacle, fluorescent lighting, a motor- or a 

transformer-operated appliance other than appropriate ceiling fans.

•   To reduce the risk of fire or electrical shock, this control is to be used with a ceiling fan that is marked as suitable for use with a solid-state fan speed control and is 

rated 120 volts, 1.5 amperes maximum.

•   For use on ceiling paddle fans with split-capacitor or shaded pole motors only. please refer to fan manufacturer’s instructions or rating labels on the motor to confirm 

type. use with any other types of motors or equipment may cause overheating and/or damage to the motors or equipment.

•   Disconnect power when servicing fixture.
•   Use this device only with copper or copper clad wire. with aluminum wire use only devices marked co/alr or cu/al.

MULTI-FAN CONTROL:

Any number of fans of the same type may be controlled by a single fan speed control provided that the total amperage of the fans does not exceed the amperage rating 

of the fan speed control.

GANGING/DERATING:

When combinations of dimming and/or speed controls are installed in a ganged wall or outlet box, derating is required. When two devices are mounted in a ganged box, 

the maximum load per device shall not exceed 1A or 500 watts. When three or more devices are mounted in a ganged box, the maximum load shall not exceed 0.7A or 

400 watts.

 FEATURES

•  Leviton’s Decora

®

 style design

•  Operates any number of ceiling fans up to rating limits
•  Fits standard wall boxes.

 ENGLISH

INSTALLATION

LIMITED 5 YEAR WARRANTY AND EXCLUSIONS

Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and 
proper use for five years from the purchase date. Leviton’s only obligation is to correct such defects by repair or replacement, at its option, if within such five year period the product is returned prepaid, with proof 
of purchase date, and a description of the problem to 

Leviton Manufacturing Co., Inc., Att: Quality Assurance Department, 59-25 Little Neck Parkway, Little Neck, New York 11362-2591.

 This warranty 

excludes and there is disclaimed liability for labor for removal of this product or reinstallation. This warranty is void if this product is installed improperly or in an improper environment, overloaded, misused, 
opened, abused, or altered in any manner, or is not used under normal operating conditions or not in accordance with any labels or instructions. 

There are no other or implied warranties of any kind, including 

merchantability and fitness for a particular purpose

, but if any implied warranty is required by the applicable jurisdiction, the duration of any such implied warranty, including merchantability and fitness for a 

particular purpose, is limited to five years. 

Leviton is not liable for incidental, indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, 

lost sales or profits or delay or failure to perform this warranty obligation

. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.

For Technical Assistance Call: 1-800-824-3005 (U.S.A. Only)

www.leviton.com

 INSTALLING YOUR DIMMER

1.  WARNING:

 To avoid fire, shock, or death; turn off power at circuit breaker or fuse and test that power is off before wiring!

2.

 Remove existing wallplate and switch, if applicable.

3.

 Remove 5/8" (1.6 cm) of insulation from each circuit conductor. Make sure the ends of wires are straight.

4.

  Connect wires per appropriate 

WIRING DIAGRAM

 as follows: Twist strands of each lead tightly together with circuit conductors and push firmly into appropriate wire 

connector. Screw connectors on clockwise making sure no bare conductors show below the wire connectors. Secure each wire (including unused wires) with electrical 

tape or small wire cap.

5.

  Installation may now be completed by carefully positioning all wires to provide room in outlet box for fan speed control. Mount fan speed control into box with 

mounting screws supplied. Attach wallplate.

6.

 Restore power at circuit breaker or fuse. 

INSTALLATION IS COMPLETE

.

Single Pole and 3-Way (Two Location)

120VAC, 60Hz

3-Speed Quiet Fan Control

 Cat. No. 6629-3, 1.5A

DI-18X-06629-22B

Wiring Diagram – Two Location Control Application

Schéma de cåblage – application pour commande au deux emplacements

Diagrama de Cableado – Aplicación de Control en Dos Ubicaciones

Hot (Black)

Actif (Noir)
Fase (Negro)

Black

Noir
Negro

Neutral (White)

 

/

 Neutre (Blanc) / Neutro (Blanco)

Red

Rouge

Rojo

Red

Rouge

Rojo

Black

Noir
Negro

White

Blanc
Blanco

Fan

Ventilateur
Ventilador

Line 120VAC, 60 Hz

Ligne 120 V c.a., 60 Hz

Línea 120VCA, 60 Hz

Common Terminal (Black Screw)

Borne commune (vis noir)
Terminal Común (Tornillo Negro)

3-Way Switch

Interrupteur à 3 voies

Interruptor de 3 Vías

3-Speed Quiet Fan Speed Control

Commande silencieuse à glissière et à 3 vitesses

Control Silencioso p/Ventilador de 3 Velocidades

Green Ground

Terre Vert

Verde a tierra

Wiring Diagram – Single Location Control Application

Schéma de cåblage – application pour commande au single emplacement

Diagrama de Cableado – Aplicación de Control en una sola Ubicación

Hot (Black)

Actif (Noir)
Fase (Negro)

Black

Noir
Negro

Neutral (White)

 

/

 Neutre (Blanc) / Neutro (Blanco)

Red

Rouge

Rojo

Red

Rouge

Rojo

Black

Noir
Negro

White

Blanc
Blanco

Fan

Ventilateur
Ventilador

Line 120VAC, 60 Hz

Ligne 120 V c.a., 60 Hz

Línea 120VCA, 60 Hz

3-Speed Quiet Fan Speed Control

Commande silencieuse à glissière et à 3 vitesses

Control Silencioso p/Ventilador de 3 Velocidades

Green Ground

Terre Vert

Verde a tierra

NOTE: This wire is unused during single pole installations.
Cover exposed wire with electrical tape or small wire cap.

REMARQUE : ce fil n’est pas utilisé dans les installations unipolaires.
Recouvrir les fils exposés d’une marette et de ruban isolant.
NOTA: Este conductor no se usa en una instalación unipolar.
Cubra el conductor  expuesto con cinta aislante o un conector pequeño.