Leviton 47605-C5B Скачать руководство пользователя страница 1

Category 5e Voice and Data Module

Cat. No. 47605-C5B 

DI-135-47605-20F

ENGLISH

INSTALLATION INSTRUCTIONS

DESCRIPTION

The Category 5e Voice and Data Module is an expansion component used to add modular voice and data 
distribution capability to any Leviton Structured Media™ Center (SMC).

1.

   Align the mounting pins with the grid holes on the back of the enclosure. Module may be mounted 

horizontally or vertically. With the mounting pin plungers in the ”out” position, press the unit into the grid 
in the desired location, secure by pushing the plungers in 

(figure 1)

.

2.

   Route and terminate up to six Category 5 or Category 5e cables from the wall jacks to the 4-Pair 110 

IDC connectors lining the sides of the module, using an industry standard punchdown tool. Each cable 
should be fully terminated (all 4 pairs) on one of the 110 IDC connectors 

(figure 2)

.

NOTE: 

Wall outlets must be compliant with T568A wiring configuration.

APPLICATION: 

•   

For data:  

Identify the cable you wish to activate and connect one end of a Category 5 or 5e patch cord 
into the corresponding module port and the other end into an installed data hub. 

EXAMPLE:

 You have a computer and a printer in your home office, and want to access the printer from 

computers in two bedrooms. Wire the unit as shown in 

figure 3

 - 

 

 

Route cables to the two office jacks (for the office computer and the printer) to corresponding  
110 IDC connectors for  
Ports 1 & 2. 

 -  

Route cables to the bedroom jacks (for the 2 bedroom computers) to corresponding 110 IDC 
connectors for Ports 3 and 4.    

 - 

 

 

Install Category 5 or 5e patch cords from ports 1, 2, 3 and 4 on the module to ports on a Data Hub 
(follow manufacturer’s instructions). The 3 computers and the printer will now be networked  
(Optical print server will be required).

• 

For voice:

 Connect a patch cord from a dial tone source, such as Leviton’s Telephone Line Distribution 

Module, to the port on the Category 5e Voice and Data Module that you wish to activate. 

NOTE:

 The Voice and Data Module ports are 8-position, 8-conductor; however, they are designed to 

accommodate 6-position or 8-position patch cords.

INSTALLATION

For Technical Assistance Call: 1-800-824-3005 (U.S.A. Only) www.leviton.com

LIMITED 2 YEAR WARRANTY AND EXCLUSIONS

Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship 
under normal and proper use for two years from the purchase date. Leviton’s only obligation is to correct such defects by repair or replacement, at its option. 

For details visit www.

leviton.com or call 1-800-824-3005.

 This warranty excludes and there is disclaimed liability for labor for removal of this product or reinstallation. This warranty is void if this product 

is installed improperly or in an improper environment, overloaded, misused, opened, abused, or altered in any manner, or is not used under normal operating conditions or not in 
accordance with any labels or instructions. 

There are no other or implied warranties of any kind, including merchantability and fitness for a particular purpose

, but if any implied 

warranty is required by the applicable jurisdiction, the duration of any such implied warranty, including merchantability and fitness for a particular purpose, is limited to two years. 

Leviton 

is not liable for incidental, indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or profits or 
delay or failure to perform this warranty obligation

. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.

FOR CANADA ONLY

For warranty information and/or product returns, residents of Canada should contact Leviton in writing at 

Leviton Manufacturing of Canada Ltd to the attention of the Quality 

Assurance Department, 165 Hymus Blvd, Pointe-Claire (Quebec), Canada H9R 1E9

 or by telephone at 

1 800 405-5320.

1

2

3

• White/Blue •

 Blanc/Bleu • 

Blanco/Azul

• Blue • 

Bleu 

• 

Azul

• White/Orange • 

Blanc/Orangé 

• 

Blanco/Naranja

• Orange • 

Orangé 

• 

Naranja

• White/Green • 

Blanc/Vert 

• 

Blanco/Verde

• Green • 

Vert 

• 

Verde

• White/Brown • 

Blanc/Brun 

• 

Blanco/Café

• Brown • 

Brun 

• 

Café

DI-135-47605-20F

© 2016 Leviton Mfg. Co., Inc.

WARNINGS AND CAUTIONS

• 

WARNING: TO AVOID DEATH OR SERIOUS PERSONAL INJURY:

 

- DO NOT

 push objects of any kind into this product through openings, as they may touch dangerous voltages.

 

- DO NOT

 touch uninsulated wires or terminals unless the wiring has been disconnected at the network interface.

•  Read and understand all instructions. Follow all warnings and instructions marked on the product.
• 

Do not use this product near water - e.g.,

 near a tub, wash basin, kitchen sink or laundry tub, in a wet basement, or near a swimming pool.

•  

Never install communications wiring or components during a lightning storm.

•  

Never install communications components in wet locations unless the components are designed specifically for use in wet locations.

•  Use caution when installing or modifying communications wiring or components.
• SAVE 

THESE 

INSTRUCTIONS.