background image

 

FEATURES

Leviton Residential Intercom System

Door Strike Board

Cat. No. 47000-STR

 

PACKAGE CONTENTS

DI-004-47000-01A

 

INSTALLATION

PW

B

69

13

9–

50

PW

A

69

13

9

IN

PU

T

O

U

TP

U

T/

AU

X

20

05

©

w w w. l e v i t o n . c o m

Leviton Intercom

Door    Strike    Board

+

+

+

+

K1

D

10

D

11

D

12

D

13

K2

K3

K4

JP5

JP6

NO

NO

NO

NO

NO

NC

NO

NC

JP7

JP8

J4

Q2

JK1

SW4

SW3

SW2

SW1

C16

D

7

D

8

D

6

D

5

D

9

U2

U1

C12

R25

JK2

ZD1

D14

X1

F1

C13

C14

Q8-1

12VDC

D15

D

1

D

C1

SW

1

D

2

D

3

D

4

1 2 3 4

+

• 

Strike Board     •     12V Power Supply       •    12" Patch Cord (1)

• 

Upgrades the Leviton Residential Intercom System with Door 

Strike capability

• 

Ease of wiring via patch cords into other modules

• 

Will support up to 4 door strikes with screw terminal connections

• 

Configurable set time delay

1.  

Mount the Door Strike board onto an available spot of the SMC 

mounting bracket.

2.

  Connect wires from door strike and strike power supply to the 

correct terminals on the terminal strip. Use terminal SW1 for door 

strike in zone 1, SW2 for door strike in zone 2, etc.

3.

  Adjust the jumper for connected zones to normally open (NO) 

or normally close (NC) as desired. “Normally open” refers to the 

contacts being open (and no current flowing) when the board is 

energized. Conversely, “normally closed” means the contacts are 

closed (with current flowing) when the board is energized. The 

contacts are rated for 1 Amp at 125VAC/30VDC.

4.

  Use the patch cord to connect output of the Intercom Main 

Controller board to the input of the Door Strike board.

5.

  Use the second patch cord to connect the output/aux of the Door 

Strike board to the input of the Intercom Interface board.

 

NOTE:

 It is important that the Door Strike module is connected 

DIRECTLY to the Intercom Main Controller board.

6.

  Set the dip switches according to the table below for the desired 

DTMF tone for activation and relay activation time.

 

NOTE:

 Chime board must be de-energized prior to changing settings.

 

NOTE:

 The LED will blink to indicate normal operation.

NOTE: 

Refer to Wiring Diagram on back page for wiring configuration.

•  Power module using 

power supply provided 

or jumper to PSA

•  This module requires 

12VDC

•  Fuse is a 1 Amp 250V 

type GFE

Delay Time

Time

DTMF

Keypad #

5 sec
1 sec
3 sec

0.5 sec

5 sec
1 sec
3 sec

0.5 sec

5 sec
1 sec
3 sec

0.5 sec

5 sec
1 sec
3 sec

0.5 sec

Switch 1

1

1

1

1

0

0

0

0

1

1

1

1

0

0

0

0

Switch 2

1

1

1

1

1

1

1

1

0

0

0

0

0

0

0

0

Switch 3

1

1

0

1

1

0

0

1

1

0

0

1

1

0

0

0

Switch 4

1

0

1

1

0

1

0

1

0

1

0

1

0

1

0

0

0

0

0

0

5

5

5

5

7

7

7

7

*
*

*
*

0 = OFF (switch away from board), 1 = ON (switch pushed toward board)