background image

WARNINGS

•  TO AVOID FIRE, SHOCK OR DEATH: TURN OFF POWER AT CIRCUIT 

BREAKER OR FUSE AND TEST THAT THE POWER IS OFF  

BEFORE WIRING!

•  TO AVOID FIRE, SHOCK, OR DEATH:

 Use with compatible 

dimmable

 LED and 

CFL bulbs, incandescent or 120V halogen fixtures only. For a complete list of 

compatible LED bulbs refer to 

www.leviton.com/led

.  

•  To be installed and/or used in accordance with electrical codes and regulations.
•  If you are not sure about any part of these instructions, consult an electrician.

CAUTIONS

•    When multiple bulbs are used with one dimmer 

DO NOT

 mix bulb types. All bulbs shall be 

either LED, CFL  

or incandescent. Using the same make/model of each bulb will enhance performance.

•    Use only one (1) dimmer in a 3-way circuit. The switch(es) will turn the light on at the 

brightness level selected at the dimmer.

•    To avoid overheating and possible damage to this device and other equipment, 

DO NOT

 

install to control a receptacle, a motor or a transformer-operated appliance, or any other 

lighting sources than those specified.

•  Use this device 

WITH COPPER CLAD WIRE ONLY

.

•  To clean use a damp cloth with mild soap.  DO NOT use disinfecting products, 

including foggers, sprays or other types of atomized cleaning agents.

In incandescent multi-dimmer installations, the reduction of the dimmer’s capacity is 
required. Refer to the chart for maximum load per dimmer. No derating is required for 
use in dimmable LED or dimmable CFL multi-dimmer installations. 

Before you install your dimmer by itself or with 

other dimmers:

MAXIMUM LOAD PER DIMMER FOR MULTI-DEVICE

Cat. No.

Load

Single

Two Devices

More than 2 Devices

06674

Incandescent

600W

500W

400W

1.  

Identify your wires (most common).

NOTE:

,IWKHZLULQJLQWKHZDOOER[GRHVQRWUHVHPEOHDQ\RIWKHVHFRQ¿JXUDWLRQVFRQVXOWDQHOHFWULFLDQ

2.  Wire.

Remove 5/8 in (1.6 cm) of insulation from each wire in the wall box.

NOTE:

 These are diagrams to represent the most common applications. Your dimmer or wallbox may not look exactly as you see in these diagrams

Single Pole

Installation

LED / CFL / Incandescent Slide Dimmer

Cat. No. 06674

INSTALLATION INSTRUCTIONS

ENGLISH

DI-000-06674-02B

Single Pole

3-Way

You will need:

•  Slotted/Phillips screwdriver
•  Pencil
•  Electrical tape

•  Cutters
•  Pliers 
•  Ruler

Cat. No.

LED/CFL

Incandescent

VAC

Hz

06674

150W

600W

120VAC

60Hz

GROUND

NEUTRAL

LOAD

LINE

To Light

From 

Branch Circuit

Dimmer Wallbox

3-Way Switch Wallbox

To Light

From Dimmer

Wallbox

GROUND

GROUND

To Switch 

Wallbox

From 

Branch Circuit

LOAD

NEUTRAL

NEUTRAL

TRAVELER 2

GROUND

GROUND

LINE

NEUTRAL

NEUTRAL

TRAVELER 2

TRAVELER 1

TRAVELER 2

TRAVELER 1

GROUND

NEUTRAL

To Light

From 

Branch Circuit

TRAVELER

LOAD

LINE

NOTE

: This wire is used in 3-way 

installations only.  Cap wire as shown 

when not in use.

Отзывы: