SISTEMA MATERASSO E COMPRESSOREA PRESSIONE ALTERNATA SERIE PIUMAMANUALE D'ISTRUZIONE
PIUMA ALTERNATING PRESSUREREDISTRIBUTION SYSTEMINSTRUCTION MANUAL
Страница 1: ...MA LAD561 LAD562 LAD563 03 A_05 2016 SISTEMA MATERASSO E COMPRESSORE A PRESSIONE ALTERNATA SERIE PIUMA MANUALE D ISTRUZIONE PIUMA ALTERNATING PRESSURE REDISTRIBUTION SYSTEM INSTRUCTION MANUAL...
Страница 2: ...g 6 13 FUNZIONAMENTO pag 7 13 1 Funzionamento generale pag 7 13 2 CPR pag 8 14 PULIZIA pag 8 15 STOCCAGGIO pag 9 16 MANUTENZIONE pag 9 17 CONDIZIONI DI SMALTIMENTO pag 9 18 PARTI DI RICAMBIO E ACCESSO...
Страница 3: ...un potenziale pericolo che richiede procedure o prassi corrette al fine di evitare danni alle persone 3 DESTINAZIONE D USO La linea di kit compressore e materasso progettata per la prevenzione e il tr...
Страница 4: ...le del dispositivo determinata dall usura di parti non riparabili e o sostituibili Prestare sempre attenzione alla presenza di bambini 6 1 Avvertenze riguardanti la compatibilit elettromagnetica Quest...
Страница 5: ...562 Sistema materasso a bolle e compressore a pressione alternata serie Piuma LAD563 Sistema materasso ad elementi e compressore a pressione alternata serie Piuma 9 DESCRIZIONE GENERALE 9 1 Compressor...
Страница 6: ...re 2 Anche la presa pu servire da interruttore per disinserire l apparecchio ATTENZIONE La pompa pu essere applicata solo al materassino consigliato dal produttore Non usarla per alcun altro scopo Ele...
Страница 7: ...libere da garze capelli e simili 8 Non far cadere e non inserire nessun oggetto nelle aperture o nei tubi 9 Non modificare questo dispositivo senza autorizzazione del produttore 10 La copertura del m...
Страница 8: ...r gonfiare il materassino consigliabile mantenere il regolatore di pressione al massimo per un gonfiaggio pi veloce Una volta gonfiato il materassino l utente pu regolarne la compattezza 13 2 CPR Quan...
Страница 9: ...timento Accertarsi che il rivestimento e i tubi siano stati stoccati correttamente 3 Verificare il flusso dell aria nei tubi Il flusso dell aria deve alternare tra i due connettori se la modalit di fu...
Страница 10: ...usato in tale ambiente PROVA DI EMISSIONE CONFORMIT AMBIENTE ELETTROMAGNETICO GUIDA Emissioni RF CISPR 11 Gruppo 1 Il sistema Piuma utilizza energia RF solo per il suo funzionamento inter no Perci le...
Страница 11: ...uttore del trasmettitore e d la distanza di separazione raccomandata in metri m Le resistenze dei campi dal trasmettitore fisso RF come determinato da un luogo del rilevamento NOTA 3 devono essere inf...
Страница 12: ...8 3 8 7 3 100 12 12 23 NOTA A 80MHz e 800MHz si applica l intervallo di frequenza pi alto NOTA Queste linee guida potrebbero non applicarsi in tutte le situazioni La propagazione elettromagnetica infl...
Страница 13: ...e a carico di Moretti se si determina che la riparazione ricade nell ambito della garanzia Una riparazione o sostituzione non rinnova n proroga la garanzia 23 2 Riparazione di un prodotto non coperto...
Страница 14: ..._______________________ Acquistato in data______________________________________________________________ Rivenditore ____________________________________________________________________ Via __________...
Страница 15: ...ag 20 13 1 General operation pag 20 13 2 Emergency operation pag 21 14 CLEANING pag 21 15 STORAGE pag 22 16 MAINTENANCE pag 22 17 CONDITIONS OF DIPOSAL pag 22 18 SPARE PARTS ACCESSORIES pag 22 19 TROU...
Страница 16: ...tial danger that requires correct procedures or practices in order to prevent personal injury 3 INTENDED USE The kit pump and mattress have been designed for the bedsore treatment and prevention which...
Страница 17: ...netic compatibility warnings This equipment has been tested and it complies with medical devices limits belonging to EN 60601 1 2 2007 These limits have been designed to provide reasonable protection...
Страница 18: ...attress and pump with pressure adjustment Piuma bubble pad LAD563 Kit mattress and pump with pressure adjustment Piuma single cells pad 9 GENERAL DESCRIPTION 9 1 Pump unit 1 2 Front 1 Power Switch 2 P...
Страница 19: ...ct the device ATTENTION The pump should only be used with mattress recommended by the manufacturer Do not use it for any other purpose 5 Turn the switch ON Several installation tips are listed below A...
Страница 20: ...or insert any object into any opening or hose 9 Do not modify this equipment without authorization of the manufacturer 10 Mattress cover has passed skin sensitization and skin irritation test However...
Страница 21: ...ecommended that the pressure first to be set to the max The user career can then adjust air mattress weight levels to the desired softness after set up has been completed 13 2 Emergency operation When...
Страница 22: ...ar 2 Check mattress cover for signs of wear or damage Ensure mattress cover and tubes are stubbed together correctly 3 Check the airflow from the air hose The airflow should alternate between each con...
Страница 23: ...tromagnetic environment specified below The user of this device should make sure it is used in such an environment EMISSIONS TEST COMPLIANCE ELECTROMAGNETIC ENVIRONMENT GUIDANCE RF emissions CISPR 11...
Страница 24: ...the com pliance level in each frequency ranged Interference may occur in the vi cinity of equipment marked with the following symbol Radiated RF IEC 61000 4 3 3 V m 80 MHz to 2 5 GHz 3 V m NOTE At 80...
Страница 25: ...equency range applies NOTE These guidelines may not apply in all situations Electromagnetic propagation is affected by absorption and reflection from structures objects and people 21 TECHNICAL FEATURE...
Страница 26: ...oretti if the repair is covered by warranty Repair or replacement does not renew or extend the warranty 23 2 Repair not covered by warranty A product not covered by warranty can be returned for repair...
Страница 27: ...______________________ Purchased on date _ ____________________________________________________________ Retailer _ ______________________________________________________________________ Address ______...