4 x 802.3af + 4 x 802.3at + 2 GE SFP Managed Switch
Quick Installation Guide
Default Setting
IP
Login
Password
Console
IES-1085
4 x 802.3af + 4 x 802.3at + 2 GE SFP Managed Switch
DIN-rail
Quick Installation Guide
192.168.1.10
root
[blank]
115200, n, 8, 1
4 x 802.3af + 4 x 802.3at + 2 GE SFP Managed Switch -40 to 75C,
Quick Installation Guide
v1.00 - 1206
IES-1085
Page 1
Overview
LevelOne IES-1085 Industry Ethernet Switch provides 8 PoE
ports of 10/100Base-TX plus 2 1000Base SFP slots Ethernet to
enable high speed network at mission-critical environment. This
device is designed to be mounted on an industry standard DIN-
rail.
High Reliability
All components are built to withstand harsh environment
applications without compromise where humidity, temperature
variation and even shock vibration are concerns, including
Electric & Utility, Critical Infrastructure, Transportation and
Surveillance Security. This device operates under -40 to 75
Celsius (-40 to 167 Fahrenheit) temperature.
Resilient Ring Network
Supports Ring topology network providing simple installation
and ultra fast network recovery performance, less than 15ms.
Unlike much complex resilient topology, such as a redundant
star, the Ring simplifies the network design and requires less
cabling installation. In addition, fast network recovery time
helps minimize system downtime.
Power over Ethernet
This switch is Power Sourcing Equipment (PSE), and it is fully
complied with IEEE 802.3af/at PoE standard at maximum
15.4/30W power budget per port. It helps to save infrastructure
wiring costs dramatically by eliminating electric wiring and less
UPS needed.
IES-1085
Page 2
Features
•
Meets NEMA TS1/TS2 Environmental requirements such as temperature,
shock, and vibration for traffic control equipment.
•
Meets EN61000-6-2 & EN61000-6-4 EMC Generic Standard Immunity for
industrial environment.
•
RS-232 console, Telnet, SNMP v1 & v2c & v3, RMON, Web Browser, and
TFTP management.
•
Supports IEEE802.3af Power over Ethernet (PoE) Power Sourcing
Equipment (PSE).
•
Supports IEEE802.3/802.3u/802.3ab/802.3z/802.3x. Auto-negotiation:
1000Mbps-full-duplex; 10/100Mbps-full/half-duplex; Auto MDI/MDIX.
•
100Base-FX: Multi mode SC or ST type, Single mode SC or ST type.
100Base-BX: WDM Single mode SC type.
•
1000Base-SX/LX: Multi mode or Single mode SC type. 1000Base-BX:
WDM Single mode SC type.
•
Alarms for power and port link failure by relay output.
•
Power Supply: Redundant 47~57VDC Terminal Block power inputs or
47~57VDC DC Jack power input.
•
Field Wiring Terminal: Use Copper Conductors Only, 60/75
℃
, 12-24 AWG
torque value 7 lb-in.
•
Operating voltage and Max. current consumption: 0.31A @ 48VDC. Power
consumption: Power consumption: 230W Max. (Full load with PoE), 15W
Max. (Without PoE).
•
-40
℃
to 75
℃
(-40
℉
to 167
℉
) operating temperature range. Tested for
functional operation @ -40
℃
to 85
℃
(-40
℉
to 185
℉
). UL508 Industrial
Control Equipment certified Maximum Surrounding Air Temperature @
75
℃
(167
℉
).
•
For use in Pollution Degree 2 Environment.
•
Metal case with Din-Rail or Panel Mounting installation
<Note> Make sure to readjust RTC Time of this switch to function
accurately after this switch has been powered off for over 72 hours.
Package Contents
IES-1085
Quick Installation Guide
CD User Manual / Utility
IES-1085
Physical Description
Front Panel
Power Input
T
e
rm
in
a
l
B
lo
c
k
PW1
PW2
Earth Ground
Relay Output
Relay Alarm warning signal disable for following:
1. The relay contact closes if Power1 and Power2 are both failed but Power3
on
2. The relay contact closes if Power3 is failed but Power1 and Power2 are both
on
•
There are three power inputs can be used. Redundant
PW3 is DC Jack type with
Physical Description
Front Panel
Rear Panel
Power Input
+
47 – 57VDC
–
Power Ground
+
47 – 57VDC
–
Power Ground
Earth Ground
Relay Output
1A @ 250VAC
arning signal disable for following:
The relay contact closes if Power1 and Power2 are both failed but Power3
The relay contact closes if Power3 is failed but Power1 and Power2 are both
There are three power inputs can be used. Redundant power function is supported
is DC Jack type with 47 – 57VDC input
Page 3
Rear Panel
The relay contact closes if Power1 and Power2 are both failed but Power3
The relay contact closes if Power3 is failed but Power1 and Power2 are both
power function is supported