IES-0520 User Manual 

Page 10 

12VDC DC Jack Input (Optional) 

Step 1: Connect the supplied AC to DC power adapter to the receptacle on the topside of 

the switch. 

 

Step 2: Connect the power cord to the AC to DC power adapter and attach the plug into a 

standard AC outlet with the appropriate AC voltage. 
 

 

 

D

C Ja

ck

 

PW1 

DC Jack 

12VDC Input 

 

Relay Output 

1A @ 24VDC 

1.

 

The relay contact close if power falls   

 
 

Содержание INFINITY IES-0520

Страница 1: ...IES 0520 4 FE 1 MM SC Unmanaged Switch 40 to 75 DIN rail User Manual v1 00 1206 ...

Страница 2: ...full wire speed switching technology This switch brings the answer to complicated Industrial networking environments To get the most out of this manual you should have an understanding of Ethernet networking concepts In this manual you will find Features on the switch Illustrative LED functions Installation instructions Specifications ...

Страница 3: ...DUCT OVERVIEW 3 INDUSTRIAL ETHERNET SWITCH 3 PACKAGE CONTENTS 3 PRODUCT HIGHLIGHTS 4 FRONT PANEL DISPLAY 5 PHYSICAL PORTS 6 INSTALLATION 7 DIN RAIL MOUNTING 8 CONNECTING TO POWER 9 CONNECTING TO YOUR NETWORK 12 SPECIFICATIONS 13 APPENDIX A CONNECTOR PINOUTS 15 ...

Страница 4: ...t Switch Package Contents When you unpack the product package you shall find the items listed below Please inspect the contents and report any apparent damage or missing items immediately to your authorized reseller IES 0520 Quick Installation Guide CD User Manual ...

Страница 5: ... MDIX Supports 2048 MAC addresses Provides 768K bits memory buffer Alarms for power and port link failure by relay output 1 5A 24VDC Operating voltage and Max current consumption 0 76A 12VDC 0 38A 24VDC 0 19A 48VDC Power consumption 9 12W Max Power Supply Redundant DC Terminal Block power inputs or 12VDC DC JACK with 100 240VAC external power supply Field Wiring Terminal Use Copper Conductors Only...

Страница 6: ... is failed or not being used Port failure When Port Fault Alarm is enabled Off Redundant power is active Port failure is not occurred Port Fault Alarm is disabled 10 100Base TX or 100Base FX BX LNK ACT Green Steady Network connection is established Flashing Transmitting or Receiving data 100 Yellow Steady Connection at 100Mbps speed Off Connection at 10Mbps speed ...

Страница 7: ...100Base TX ports Eight 10 100Base TX ports one 100Base FX BX port Six 10 100Base TX ports two 100Base FX BX ports Four 10 100Base TX ports four 100Base FX BX ports Connectivity RJ 45 connectors SC or ST connector on 100Base FX fiber port SC connector on 100Base BX fiber port ...

Страница 8: ...ic interference Specifically the site you select should meet the following requirements The ambient temperature should be between 40 to 75 degrees Celsius The relative humidity should be less than 95 percent non condensing Surrounding electrical devices should not exceed the electromagnetic field RFC standards Make sure that the switch receives adequate ventilation Do not block the ventilation hol...

Страница 9: ...late to the back panel of the switch Installation Place the switch on the DIN rail from above using the slot Push the front of the switch toward the mounting surface until it audibly snaps into place Removal Pull out the lower edge and then remove the switch from the DIN rail ...

Страница 10: ...r PWR2 is dead This device however continues working normally even fault LED indicator lights up Step 1 Connect the DC power cord to the plug able terminal block on the switch and then plug it into a standard DC outlet Step 2 Disconnect the power cord if you want to shut down the switch Field Wiring Terminal Use Copper Conductors Only 60 75 12 24 AWG torque value 7 lb in Terminal Block PW1 10 48VD...

Страница 11: ...C power adapter to the receptacle on the topside of the switch Step 2 Connect the power cord to the AC to DC power adapter and attach the plug into a standard AC outlet with the appropriate AC voltage DC Jack PW1 DC Jack 12VDC Input Relay Output 1A 24VDC 1 The relay contact close if power falls ...

Страница 12: ...ignal for power failure detection This DIP Switch features the Port Fault Detection once enabled it sends fault signal relay opens when the port link is broken On Enable Port Fault Detection Off Disable Port Fault Detection Note Pin No maps to Port No extra Pin has no function Special note The relay output is normal open position when there is no power to the switch Please do not connect any power...

Страница 13: ...40 km 1000Base SX SC 2000 Mbps MMF 62 5μm 220 m 2 km 1000Base SX SC 2000 Mbps MMF 50μm 550 m 1000Base LX SC 2000 Mbps SMF 10μm 10 20 50 km 1000Base BX SC 2000 Mbps SMF 10μm 20 40 km SFP 1000Base SX Duplex LC 2000 Mbps MMF 62 5μm 550 m 2 km 1000Base LX Duplex LC 2000 Mbps SMF 9μm 10 40 60 km 1000Base BX Duplex LC 2000 Mbps SMF 9μm 70 km Cabling Step 1 First ensure the power of the switch and end de...

Страница 14: ...icators Per unit Power status Power 1 Power 2 FAULT Per port 10 100TX or 100FX BX LNK ACT Green 100 Yellow Dimensions 50mm W 110mm D 135mm H 1 97 W x 4 33 D x 5 31 H Net Weight 0 8Kg 1 76lbs Power Terminal Block 10 48VDC DC Jack 12VDC External AC DC required Operating Voltage Max Current Consumption 0 76A 12VDC 0 38A 24VDC 0 19A 48VDC Power Consumption 9 12W Max Operating Temperature 40 to 75 40 t...

Страница 15: ...61000 4 4 Burst Standards EN61000 4 5 Surge Standards EN61000 4 6 Induced RFI Standards EN61000 4 8 Magnetic Field Standards Environmental Test Compliance IEC60068 2 6 Fc Vibration Resistance IEC60068 2 27 Ea Shock IEC60068 2 32 Ed Free Fall NEMA TS1 2 Environmental requirements for traffic control equipment ...

Страница 16: ...tor and Cable Pins The following table lists the pinout of 10 100Base TX ports Pin Standard Port Uplink Port 1 Output Transmit Data Input Receive Data 2 Output Transmit Data Input Receive Data 3 Input Receive Data Output Transmit Data 4 NC NC 5 NC NC 6 Input Receive Data Output Transmit Data 7 NC NC 8 NC NC ...