89
–
Chapter 3
| Basic Management Tasks
Configuring Telnet Settings
Configuring Telnet Settings
Use the System > Telnet menu to configure parameters for accessing the CLI over a
Telnet connection. You can access the onboard configuration program over the
network using Telnet (i.e., a virtual terminal). Management access via Telnet can be
enabled/disabled and other parameters set, including the TCP port number, time
outs, and a password. Note that the password is only configurable through the CLI.)
These parameters can be configured via the web or CLI interface.
Parameters
The following parameters are displayed:
◆
Telnet Status
–
Enables or disables Telnet access to the switch.
(Default: Enabled)
◆
TCP Port
–
Sets the TCP port number for Telnet on the switch. (Range: 1-65535;
Default: 23)
◆
Max Sessions
–
Sets the maximum number of Telnet sessions that can
simultaneously connect to this system. (Range: 0-8; Default: 8)
A maximum of eight sessions can be concurrently opened for Telnet and
Secure Shell (i.e., both Telnet and SSH share a maximum number of eight
sessions).
◆
Login Timeout
–
Sets the interval that the system waits for a user to log into
the CLI. If a login attempt is not detected within the timeout interval, the
connection is terminated for the session. (Range: 10-300 seconds; Default: 300
seconds)
◆
Exec Timeout
–
Sets the interval that the system waits until user input is
detected. If user input is not detected within the timeout interval, the current
session is terminated. (Range: 60-65535 seconds; Default: 600 seconds)
◆
Password Threshold
–
Sets the password intrusion threshold, which limits the
number of failed logon attempts. When the logon attempt threshold is
reached, the system interface becomes silent for a specified amount of time
(set by the Silent Time parameter) before allowing the next logon attempt.
(Range: 1-120; Default: 3 attempts)
◆
Silent Time
–
Sets the amount of time the management interface is
inaccessible after the number of unsuccessful logon attempts has been
exceeded. (Range: 1-65535 seconds; Default: Disabled)
Note:
The password for the Telnet connection can only be configured through the
CLI (see the
“password”
command in the
CLI Reference Guide
).
Note:
Password checking can be enabled or disabled for login to the console
connection (see the “login” command in the
CLI Reference Guide
). You can select
Содержание GEL-5261
Страница 14: ...14 Contents Glossary 551 Index 559...
Страница 26: ...26 Figures...
Страница 30: ...30 Section I Getting Started...
Страница 42: ...42 Section II Web Configuration IP Services on page 527...
Страница 45: ...Chapter 2 Using the Web Interface NavigatingtheWebBrowserInterface 45 Figure 1 Dashboard...
Страница 62: ...62 Chapter 2 Using the Web Interface NavigatingtheWebBrowserInterface...
Страница 180: ...Chapter 6 Address Table Settings Issuing MAC Address Traps 180...
Страница 208: ...Chapter 8 Congestion Control Storm Control 208 Figure 121 Configuring Storm Control...
Страница 218: ...218 Chapter 9 Class of Service Layer 3 4 Priority Settings Figure 128 Configuring DSCP to Queue Mapping...
Страница 228: ...228 Chapter 10 Quality of Service Attaching a Policy Map to a Port...
Страница 332: ...Chapter 12 Security Measures ARP Inspection 332 Figure 207 Displaying the ARP Inspection Log...
Страница 436: ...Chapter 13 Basic Administration Protocols LBD Configuration 436...
Страница 488: ...488 Chapter 14 Multicast Filtering Filtering MLD Query Packets on an Interface...
Страница 498: ...Chapter 15 IP Tools Address Resolution Protocol 498...
Страница 517: ...517 Chapter 16 IP Configuration Setting the Switch s IP Address IP Version 6 interface...
Страница 542: ...540 Section III Appendices...
Страница 560: ...Glossary 558...
Страница 569: ...567 Index web interface access requirements 43 configuration buttons 46 menu list 47 panel display 46...
Страница 570: ...568 Index E062017 ST R01...