–
131
–
Chapter 4
| Interface Configuration
Saving Power
Saving Power
Use the Interface > Green Ethernet page to enable power savings mode on the
selected port.
Command Usage
◆
IEEE 802.3 defines the Ethernet standard and subsequent power requirements
based on cable connections operating at 100 meters. Enabling power saving
mode can reduce power used for cable lengths of 60 meters or less, with more
significant reduction for cables of 20 meters or less, and continue to ensure
signal integrity.
◆
The power-saving methods provided by this switch include:
■
Power saving when there is no link partner:
Under normal operation, the switch continuously auto-negotiates to find a
link partner, keeping the MAC interface powered up even if no link
connection exists. When using power-savings mode, the switch checks for
energy on the circuit to determine if there is a link partner. If none is
detected, the switch automatically turns off the transmitter, and most of
the receive circuitry (entering Sleep Mode). In this mode, the low-power
energy-detection circuit continuously checks for energy on the cable. If
none is detected, the MAC interface is also powered down to save
additional energy. If energy is detected, the switch immediately turns on
both the transmitter and receiver functions, and powers up the MAC
interface.
■
Power saving when there is a link partner:
Traditional Ethernet connections typically operate with enough power to
support at least 100 meters of cable even though average network cable
length is shorter. When cable length is shorter, power consumption can be
reduced since signal attenuation is proportional to cable length. When
power-savings mode is enabled, the switch analyzes cable length to
determine whether or not it can reduce the signal amplitude used on a
particular link.
Note:
Power savings can only be implemented on Gigabit Ethernet ports when
using twisted-pair cabling. Power-savings mode on a active link only works when
connection speed is 1 Gbps, and line length is less than 60 meters.
Parameters
These parameters are displayed:
◆
Port
–
Power saving mode only applies to the Gigabit Ethernet ports using
copper media.
Содержание GEL-5261
Страница 14: ...14 Contents Glossary 551 Index 559...
Страница 26: ...26 Figures...
Страница 30: ...30 Section I Getting Started...
Страница 42: ...42 Section II Web Configuration IP Services on page 527...
Страница 45: ...Chapter 2 Using the Web Interface NavigatingtheWebBrowserInterface 45 Figure 1 Dashboard...
Страница 62: ...62 Chapter 2 Using the Web Interface NavigatingtheWebBrowserInterface...
Страница 180: ...Chapter 6 Address Table Settings Issuing MAC Address Traps 180...
Страница 208: ...Chapter 8 Congestion Control Storm Control 208 Figure 121 Configuring Storm Control...
Страница 218: ...218 Chapter 9 Class of Service Layer 3 4 Priority Settings Figure 128 Configuring DSCP to Queue Mapping...
Страница 228: ...228 Chapter 10 Quality of Service Attaching a Policy Map to a Port...
Страница 332: ...Chapter 12 Security Measures ARP Inspection 332 Figure 207 Displaying the ARP Inspection Log...
Страница 436: ...Chapter 13 Basic Administration Protocols LBD Configuration 436...
Страница 488: ...488 Chapter 14 Multicast Filtering Filtering MLD Query Packets on an Interface...
Страница 498: ...Chapter 15 IP Tools Address Resolution Protocol 498...
Страница 517: ...517 Chapter 16 IP Configuration Setting the Switch s IP Address IP Version 6 interface...
Страница 542: ...540 Section III Appendices...
Страница 560: ...Glossary 558...
Страница 569: ...567 Index web interface access requirements 43 configuration buttons 46 menu list 47 panel display 46...
Страница 570: ...568 Index E062017 ST R01...