background image

 

1

 

FHU-0803TXD                       
8 Port 10/100Mbps             
Dual Speed Ethernet Hub 
with Bridge 

 

This quick start guide contains the information necessary to install 
and operate the

 

FHU-0803TXD 

 8 port 10BASE-T/100BASE-TX 

dual speed Ethernet Hub

.   

Introduction 

The FHU-0803TXD provides 8 RJ-45 ports for both 10 Mbps or 

100 Mbps Ethernet connections, which are detected by auto-
sensing. The dual-speed hub contains two internal repeater buses, 

one for 10 Mbps traffic and another for 100 Mbps traffic. Traffic 
passing between attached devices that operate at the same speed is 

confined within the appropriate repeater bus. 

In the FHU-0803TXD, an internal Ethernet switch consisting of a 
10 Mbps and a 100 Mbps switching port, is used to link the 

repeater buses. Only if traffic has to be passed between a 10 Mbps 
and a 100 Mbps device, the data will be forwarded to the other 

internal repeater bus if the destination address is not found in the 
address table, or broadcast traffic is sent.  

Содержание FHU-0803TXD

Страница 1: ...ontains two internal repeater buses one for 10 Mbps traffic and another for 100 Mbps traffic Traffic passing between attached devices that operate at the same speed is confined within the appropriate...

Страница 2: ...nels the data to the appropriate backplane which is the 10 or 100 Mbps repeater bus The FHU 0803TXD contains a 2 port switch to connect these two repeater buses The learning function of the internal s...

Страница 3: ...ion port plus the overall condition affecting the hub LED Color Indication Power POWER Green ON Unit is receiving power OFF Power is disconnected no power received Collision COL Orange ON Collision ha...

Страница 4: ...Port is in 100 Mbps connection OFF Port is in 10 Mbps connection Switch Position There is a switch MDI X MDI on the front side Make sure the switch is in the correct position Switch Position Indicatio...

Страница 5: ...should be located in a cool dry place with at least 10 cm 4 in of space at the front and back for ventilation Place the hub out of direct sunlight and away from heat sources or areas with a high amou...

Страница 6: ...nto port 8 of the hub and plug the other end of the cable into any port of the other switch Note When switch MDI X MDI set to MDI the port 8 of the unit cannot be used as a station port 4 When externa...

Страница 7: ...after making a connection Cause Network interface network cable or hub port is defective Solution Verify that the hub and attached device are powered on Be sure the cable is plugged into both the hub...

Страница 8: ...lded twisted pair shielded twisted pair Interfaces 8 RJ 45 station ports 1 RJ 45 daisy chain MDI port Hub to Workstation Distance 100 meters maximum using category 5 UTP or STP cable Indicator Panel L...

Страница 9: ...CSA NRTL T V GS Switching Criteria Network Bridging Function filtering forwarding and learning Switching Method store and forward Address Table 1K entries Queue Buffer 120KB Buffer per port Filtering...