background image

R

Manual

VIEWSONIC2 SERIES

VIEWSONIC2 Series

Operating Instructions

set

ala

r

m

TANK LEVEL

TIME

14.2

2 1.

2 1

: 4 3

7

9

100%

ON

10%

FEET

+/max/min

-/tank

C

Содержание VIEWSONIC2 Series

Страница 1: ...R Manual VIEWSONIC2 SERIES VIEWSONIC2 Series Operating Instructions set alarm TANK LEVEL TIME 14 2 2 1 2 1 43 7 9 100 ON 10 FEET max min tank C...

Страница 2: ...lation Please pay attention to the following issues in installation 1 The distance between transmitter bottom and highest water surface must be 0 5m 1 64ft or more 2 The maximum depth the unit can mea...

Страница 3: ...the wireless solar transmitter 6 x AAA and then insert batteries immediately into the LCD display base unit 2 x AA Once the batteries are in place all segments of the LCD will light up briefly R Manu...

Страница 4: ...Displayed 3 1 Program Sensor Range R Manual VIEWSONIC2 SERIES TANK F TIME PM AL LEVEL 100 EMPTY HI AL LO AL 8 8 8 88 8 8 8 8 M FEET ON MAX MIN FULL 10 1 16 2 3 4 5 6 7 8 9 10 11 15 14 13 12 Figure 7 F...

Страница 5: ...nd air gap are not set correctly In normal display mode press key for 3 seconds to enter SET mode Figure 10 HOUR Hour value will flash Press or key to increase or decrease hour value When hour value i...

Страница 6: ...IES 3 3 Set Temperature Unit 3 4 Set Tank Level Unit set max min tank set set max min tank max min tank set alarm max min tank TANK F TIME PM AL LEVEL 100 EMPTY HI AL LO AL M FEET ON MAX MIN 10 FULL s...

Страница 7: ...re Figure 15 3 5 Check and Reset MIN MAX Value max min set alarm max min tank TANK F TIME PM AL LEVEL 100 EMPTY HI AL LO AL M FEET ON MAX MIN 10 FULL set alarm max min tank TANK F TIME PM AL LEVEL 100...

Страница 8: ...0 EMPTY HI AL LO AL M FEET ON MAX MIN 10 FULL set alarm max min tank TANK F TIME PM AL LEVEL 100 EMPTY HI AL LO AL M FEET ON MAX MIN 10 FULL set max min Figure 19 set alarm max min tank TANK F TIME PM...

Страница 9: ...ax min tank TANK F TIME PM AL LEVEL 100 EMPTY HI AL LO AL M FEET ON MAX MIN 10 FULL max min set alarm max min tank TANK F TIME PM AL LEVEL 100 EMPTY HI AL LO AL M FEET ON MAX MIN 10 FULL set Figure 23...

Страница 10: ...k TANK F TIME PM AL LEVEL 100 EMPTY HI AL LO AL M FEET ON MAX MIN 10 FULL max min set alarm max min tank TANK F TIME PM AL LEVEL 100 EMPTY HI AL LO AL M FEET ON MAX MIN 10 FULL set Figure 27 set alarm...

Страница 11: ...et default 10m OFF 8 Water level LO alarm 0 15m 0 feet 49 2 feet default 2m OFF Transmission Distance max 100 metres in open space Frequency 433MHz Indoor temperature range 0 to 50 C Resolution 1 C Ac...

Страница 12: ...all probe and make it perpendicular to liquid surface 5 Select an appropriate position for installation and prevent an interfering object 6 Raise the installation position of probe 7 Check whether the...

Отзывы: