Leuze electronic GmbH + Co. KG
MA 238
i
34
Figure 9.2: COM port settings
Commands
You can now call up information on the MA 238
i
by sending the following commands.
Information
NOTE
Observe that STX, data, CR, LF framing must be set on the PC terminal program so that com
-
munication is possible with the connected Leuze device.
v
General service information.
s
Enable memory mode for the last frames.
l
The memory mode shows the last RX and TX frames for ASCII and fieldbus.
Table 9.1:
Available commands
Version
Version information.
Firmware Date
Firmware date.
Table 9.2:
General firmware information
Selected scanner
Currently selected Leuze device (selected via switch S4).
Gateway mode
Transparent or Collective mode.
Ring Buffer fill level
Current fill level of the ring memory in Collective mode (ASCII
-
>Fieldbus).
1024 bytes max.
Received ASCII Frames
Number of received ASCII frames.
ASCII Framing Error (GW)
Number of received framing errors.
Number of Received CTB's
Number of CTB commands.
Number of Received SFB's
Number of SFB commands.
Command-Buffer fill level
Current fill level of the ring memory in Command mode (fieldbus
-
>ASCII).
1024 bytes max.
Number of Received Transparent Frames
Number of received fieldbus frames without CTB/SFB.
Number of sent Fieldbus Frames
Number of frames sent via the fieldbus.
Number of invalid commands
Number of invalid commands.
Number of ASCII stack send errors
Number of frames that the ASCII memory could not send.
Number of good ASCII send frames
Number of frames that the ASCII memory sent successfully.
Table 9.3:
General gateway information