Leuze electronic GmbH + Co. KG
MA 238
i
51
12.5.3.7 Object 6000 Inputs
The object describes the input data of the MA 238
i
, which is transmitted cyclically, 8 bytes by 8 bytes (Rx).
12.5.3.8 Object 7000 Outputs
The object describes the output data of the MA 238
i
, which is transmitted cyclically, 8 bytes by 8 bytes (Tx).
12.5.3.9 Object 8000 Serial Settings
The object describes the serial RS 232 settings of the MA 238
i
.
Index
Sub-index
Name
Data type
Access
Value range
Comment
(hex)
(hex)
Minimum
Maximum
Default
6000
--
Inputs
u32
rw
--
01
8 Byte Inputs (1)
ro
00 00 00 00 00
00 00 00
02
8 Byte Inputs (2)
ro
00 00 00 00 00
00 00 00
03
8 Byte Inputs (3)
ro
00 00 00 00 00
00 00 00
04
8 Byte Inputs (4)
ro
05
8 Byte Inputs (5)
ro
06
8 Byte Inputs (6)
ro
07
8 Byte Inputs (7)
ro
08
8 Byte Inputs (8)
ro
1F
8 Byte Inputs (31)
ro
20
8 Byte Inputs (32)
ro
Index
Sub-index
Name
Data type
Access
Value range
Comment
(hex)
(hex)
Minimum
Maximum
Default
7000
--
Outputs
u32
rw
--
--
01
8 Byte Outputs (1)
ro
00 00 00 00 00
00 00 00
02
8 Byte Outputs (2)
ro
03
8 Byte Outputs (3)
ro
04
8 Byte Outputs (4)
ro
1E
8 Byte Outputs (30)
ro
1F
8 Byte Outputs (31)
ro
20
8 Byte Outputs (32)
ro
Index
Sub-index
Name
Data type
Access
Value range
Comment
(hex)
(hex)
Minimum
Maximum
Default
8000
--
Serial Settings
u32
rw
--
--
01
Data Mode
u32
rw
--
--
Transparent
Mode (0)
02
Use rotary switch
u32
rw
--
--
Use rotary
switch (1)
03
Baud Rate
u32
rw
--
--
9600 Baud
(96)
04
Data Bits
u32
rw
--
--
8 Data Bits (8)
05
Parity
u32
rw
--
--
None (1)
06
Stop bits
u32
rw
--
--
1 stop bit (1)