LESsoft configuration software
Leuze electronic
LES 36
76
TNT
35/7-2
4
V
Field of View
Using
Field of View
you can restrict the measurement range of the LPS. The same
happens if you click on the square handles of the measurement range framed in blue with
the mouse and then pull.
Factory settings for
Field of View
:
By restricting to the necessary detection range, ambient light or undesired reflections can
be suppressed.
Apply Settings
The
Apply Settings
button temporarily transmits the settings for the current inspection
task to the sensor. When switched off, the data/settings are lost.
Note!
If an inspection task was changed, permanent storage in the sensor should be performed
with
Configuration -> Transmit to Sensor
.
9.4.2
Standard tab - Analysis Functions panel
In the
Analysis Functions
panel, the primary settings of the LES for realizing applica-
tions are made.
Edit Analysis Windows
In the
Analysis Functions
panel, use the
Edit Analysis Windows
button to define
the rectangular analysis windows. You can define up to four edge analysis windows (EAW
- Edge Analysis Window) and up to four normal analysis windows (AW - Analysis Window).
Note!
EAWs are used for edge detection; they can also be used for object detection. In AWs,
only object detection is possible. How evaluation of the measurements functions with
EAWs and AWs is described in Chapter 4.3 and Chapter 4.4.
Click the
Edit Analysis Windows
button to open the table for defining the analysis
windows.
LES 36…
LES 36HI…
Min
X
-300
-70
Max.
X
300
70
Min.
Y
190
190
Max.
Y
810
610