Display and control panel
Leuze electronic
LES 36
59
TNT
35/7-2
4
V
displays the next option for
Display
(
Auto
).
selects the new value
Off
and displays the menu for confirmation:
changes the edit mode;
appears
saves the new value (
Off
).
changes the edit mode;
appears
rejects the new value (
On
remains saved).
Note
To ensure that values that were changed via the menu are also applied, you should discon-
nect the sensor from its power supply for a brief period after a change of values.
7.3
Reset to factory settings
The factory settings can be reset in three different ways:
• Hold down the
button while connecting the supply voltage
• Factory Setting menu item
• By means of the LESsoft configuration software
As an example, the first of the methods mentioned above is described below:
When applying the supply voltage, press the
button to reset the configuration of the
LES to factory settings.
The display shown next to here appears.
Interrupting a reset
Pressing
causes the adjacent display to appear. If you now press the
button, you will exit the menu without resetting the LES to factory
settings.
Executing a reset
Pressing the
button while the checkmark (
) is displayed causes
the adjacent safety prompt to appear.
Pressing
interrupts the reset process;
reset canceled
appears in
the display for approx. 2s. Afterward, the LES returns to measure mode.
Pressing
resets all parameters to the factory settings. All settings
made previously are permanently lost.
reset done
appears in the
display for approx. 2s; the LES then returns to measure mode.
You can select the resetting to factory settings also via LESsoft.
In the
Configuration
menu select the entry
Reset to Factory Settings
.
Display
Off
Display
Off
Display
Off
FactorySettings
Execute
FactorySettings
Execute
Really Reset?
Yes (
) No (
)
reset canceled
reset done