Display and control panel
Leuze electronic
LES 36
55
TNT
35/7-2
4
V
7.2
Menu description
7.2.1
Structure
Level 1
Level 2
Level 3
Level 4
Explanation / Notes
Default
Select Insp. Task
Appl. Settings
Select Inspection Task menu item
Ext. Selection
Enabled
Change task via digital inputs (external)
Ext. Selection
Enabled
Change task via digital inputs (external) is
activated.
X
Ext. Selection
Disabled
Change task via digital inputs (external) is
deactivated.
1)
Select Insp. Task
00:Task 0
Selection of the active inspection task
2)
Select Insp. Task
00:Task 0
Task 0 is activated.
X
:
:
Select Insp. Task
15:Task 15
Task 15 is activated.
Ext. Selection
Return to menu level 1
Appl. Settings
3)
Device Settings
Application Settings menu item
Exposure Time
Normal Mode
Exposure time for measurements and
teaching
Exposure Time
Normal Mode
"Normal" exposure time setting
X
Exposure Time
Bright Objects
"Bright Objects" exposure time setting
Exposure Time
Dark Objects
"Dark Objects" exposure time setting
Exposure Time
Manual Setting
"Manual" exposure time setting
(user-specific setting)
4)
Trigger Mode
Free Running
Trigger mode for measurements
Trigger Mode
Free Running
"Free Running" trigger setting
(continuous measurement)
X
Trigger Mode
Input Triggered
"Input Triggered" trigger setting
(trigger-input signal triggers measurement)
Exposure Time
Return to menu level 1
Device Settings
Error Handling
Device Settings menu item
Slave Address
Ethernet
PROFIBUS DP slave address
5)
Slave Address
1
26
Setting for the PROFIBUS DP slave address
126
Ethernet
Display
Ethernet interface parameters
6)
IP Address
192.168.060.003
IP address of the sensor
Table 7.2:
Menu structure